Universal AC input / Full range
Built-in active PFC function, PF>0.95
High efficiency up to 89.5%
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in constant current limiting circuit
Medical safety approved (MOOP level)
Built-in cooling Fan ON-OFF control
Built-in DC OK signal
Built-in remote ON-OFF control
Stand by 5V@0.3A
Built-in remote sense function
No load power consumption<0.6W (Note.6)
5 years warranty
SPECIFICATION
MSP-450-3.3 MSP-450-5 MSP-450-7.5 MSP-450-12 MSP-450-15 MSP-450-24 MSP-450-36 MSP-450-48
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.) Note.2
OUTPUT VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
SAFETY STANDARDS
SAFETY &
FUNCTION
EMC
(Note 8)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP.
DC OK SIGNAL
REMOTE CONTROL
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
PROTECTION
AC CURRENT (Typ.)
3.3V 5V 7.5V 12V 15V 24V 36V 48V
90A 90A 60A 37.5A 30A 18.8A 12.5A 9.5A
0 ~ 90A 0 ~ 90A 0 ~ 60A 0 ~ 37.5A 0 ~ 30A 0 ~ 18.8A 0 ~ 12.5A 0 ~ 9.5A
297W 450W 450W 450W 450W 451.2W 450W 456W
80mVp-p 80mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p 240mVp-p 240mVp-p
2.8 ~ 3.8V 4.3 ~ 5.8V 6.8 ~ 9V 10.2 ~ 13.8V 13.5 ~ 18V 21.6 ~ 28.8V 28.8 ~ 39.6V 40.8 ~ 55.2V
±2.0% ±2.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±0.5% ±0.5% ±0.5% ±0.3% ±0.3% ±0.2% ±0.2% ±0.2%
±1.0% ±1.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
1000ms, 100ms/230VAC 2500ms, 100ms/115VAC at full load
16ms/230VAC 16ms/115VAC at full load
85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
PF>0.95/230VAC PF>0.99/115VAC at full load
80% 83%
6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 41.4 ~ 48.6V 57.6 ~ 67.2V
86.5% 88% 89% 88% 89% 89.5%
5A/115VAC 2.4A/230VAC
35A/115VAC 70A/230VAC
105 ~ 135% rated output power
3.96 ~ 4.62V
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
ANSI/AAMI ES60601-1, IEC60601-1, approved
EAC TP TC 004
Compliance to EN55011 (CISPR11) Class B, EN61000-3-2,-3,EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN60601-1-2,EAC TP TC 020
I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
-40 ~ +70 (Refer to "Derating Curve")
RC+ / RC-: 4 ~ 10V or open = power on ; 0 ~ 0.8V or short = power off
PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH non-condensing
±℃ 0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
159.3K hrs min. MIL-HDBK-217F (25 )
218*105*41mm (L*W*H)
File Name:MSP-450-SPEC 2018-01-15
Features :
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
6. No load power consumption<0.5W when RC- & RC+ (CN100 pin1,2) 0 ~ 0.8V or short.
7. When the input voltage is less than 40VAC, the SPS may exhibit degradation of performance. The final product manufacturers must re-confirm this
deviation that does not affect basic safety or essential performance.
8. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
9. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
MSP-450 series
450W Single Output Medical Type
1.19Kg; 12pcs/15.3Kg/0.82CUFT
5V STANDBY
5VSB : 5V@0.3A ; tolerance 5%, ripple : 50mVp-p(max.)±
FAN CONTROL (Typ.)
Load 20 10% or RTH2 50 Fan on±≧
EMC IMMUNITY
EMC EMISSION
Earth leakage current < 300 A/264VAC , Touch leakage current < 100 A/264VAC
μμ
ISOLATION LEVEL
Primary-Secondary: 2×MOOP, Primary-Earth: 1×MOOP, Secondary-Earth: 1×MOOP
Mechanical SpecificationMechanical Specification Case No. 995A Unit:mm
AC Input Terminal Pin No.
Assignment
DC Output Terminal Pin No.
Assignment
Pin No. Pin No.
1 1~3
3
2 4~6
Assignment Assignment
AC/N +V
AC/L -V
FG
Derating Curve Output Derating VS Input Voltage
INPUT VOLTAGE (V) 60Hz
85 100 125 135 155 264
100
90
80
70
60
50
40
LOAD(%)
AMBIENT TEMPERATURE ( )
LOAD (%)
-40010203040506070
20
50
80
100
125
(HORIZONTAL)
PWM fosc : 70KHz
Block Diagram
Pin No. Pin No.
5
3
2
1
6
4
7
8
Assignment
-S
+S
DC-OK
GND
Assignment
AUXG
AUX
RC-
RC+
Mating Housing Terminal
or equivalent or equivalent
Connector Pin No. Assignment(CN100) : HRS DF11-8DP-2DS or equivalent
HRS DF11-8DS
HRS DF11-**SC
O.L.P.
O.T.P.
EMI INRUSH
ACTIVE
FILTER CURRENT
LIMITING
RECTIFIERS
&
PFC
I/P
FG
PWM
PFC
CIRCUIT
DETECTION
POWER
AUX
SWITCHING
POWER
FILTER
FILTER
&
&
RECTIFIERS
RECTIFIERS
CONTROL
CONTROL
O.V.P.
O.T.P.
REMOTE
CONTROL
3
2
1
119.2
1
2
3
4
5
6
+V
+S
AUX
-V
-S
AUXG
RC+
DC OK
RC-
450W Single Output Medical Type
File Name:MSP-450-SPEC 01-152018-
MSP-450 series
32.8152.4
Air flow
direction FAN
12max.
I/P
20.75
8.2
10
41
CN100
LED
(Vo ADJ.)SVR1
8
7
2
1
152.4
218
O/P
105
4-M4 L=5
63.5
18
8-M4 L=4 (Both Sides)
32.8
18max.
12.5
The remote sensing compensates voltage drop on
the load wiring up to 0.5V.
8
8
7
7
CN100
AUX
AUX
AUX
GND
GND
GND
-S
-S
-S
AUXG
AUXG
AUXG
DC-OK
DC-OK
DC-OK
+S
+S
+S
2
2
1
1
1.Remote Sense
Sense lines should
be twisted in pairs
LOAD
-
+
+S -S
(Pin7) (Pin8)
Fig 1.1
Between DC-OK(pin5) and GND(pin6)
3.3 ~ 5.6V
0 ~ 1V
Output Status
ON
OFF
DC-OK signal is a TTL level signal. High when PSU turns on.
CN100
2.DC-OK Signal
Fig 2.1
Fig 3.1
5DC-OK DC-OK Signal is a TTL level signal, referenced to pin6(DC-OK GND). High when PSU turns on.
7+S
Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
8-S
Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
6GND This pin connects to the negative terminal(-V). Return for DC-OK signal output.
RC-
RC-
RC-
RC+
RC+
RC+
CN100
CN100
CN100
8
8
8
7
7
7
2
2
2
1
1
1
450W Single Output Medical Type
File Name:MSP-450-SPEC 01-152018-
MSP-450 series
Function Description of CN100
Pin No. Function Description
Function Manual
1
2
RC+
RC- Remote control ground.
Turns the output on and off by electrical or dry contact between pin 2 (RC-), Short: Power OFF, Open: Power ON.
3
4
AUX
AUXG Auxiliary voltage output ground. The signal return is isolated from the output terminals (+V & -V).
87
21
Between RC+(pin1) and RC-(pin2)
SW ON (Short)
SW OFF (Open)
Output Status
OFF
ON
The PSU can be turned ON/OFF by using the
"Remote Control" function.
SW
CN100
3.Remote Control
Auxiliary voltage output, 4.75~5.25V, referenced to pin 4(AUXG). The maximum load current is 0.3A. This output is not controlled by the
"remote ON/OFF control".