9
WL/WLM
Model Number Structure
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
WL @@-@@@@@@@@
(1) (2) (3) (4) (5) (6) (7) (8) (9)(10)
(6) Hermetic Model Specifications
* Refer to page 4 for applicable models.
(8) Indicator Type
Note: Dimensions are the same for both LE and LD models.
(9) Indicator Wiring
Note: Include the indicator wiring specification only when a (6) hermetic seal
and (8) operation indicator have been selected.
(10) Lever Type
General-purpose and Environment-resistant Switches
(1) Electrical Rating
Note: Dimensions are the same as the standard
models.
(3) Environment-resistant Model
Specifications
Note: Dimensions are the same as the standard
models.
*1. Refer to page 4 for applicable models.
(4) Built-in Switch Type
Note: Dimensions are the same as the standard
models.
*1. Refer to page 4 for applicable models.
(5) Temperature Specifications
Note: Dimensions are the same as the standard
models.
*1. Refer to page 4 for applicab le models.
(7) Conduit Size, Ground Terminal
Specifications *2
Note: Dimensions are the same as the standard
models.
*2. Models with ground terminals are appr oved by
EN/IEC (CE marking).
Blank Standard load
01 Microload
Blank Standard
RP Corrosion-proof *1
P1 Weather-proof *1
Blank Standard
55 Hermetically sealed *1
Blank Standard: –10°C to +80°C
TH Heat-resistant: +5°C to +120°C *1
TC
Low-temperature: –40
°
C to +40
°
C *1
Blank G1/2 without ground terminal
G1 G1/2 with ground terminal
GPg13.5 with ground terminal
YM20 with ground terminal
TS 1/2-14NPT with ground terminal
(2) Actuator and Head Specifications
Symbol Actuator type
Switch without lever
CA2 Roller lever: Standard model R38 WLRCA2
CA2-7 Roller lever: Standard model R50 WLRCA2
CA2-8 Roller lever: Standard model R63 WLRCA2
H2 Roller lever: General-purpose overtravel model, 80°WLRH2
G2 Roller lever: High-sensitivity overtravel, 80°WLRG2
CA2-2 Roller lever: Overtravel, 90°WLRCA2-2
CA2-2N Roller lever: Overtravel, 90°WLRCA2-2N
GCA2 Roller lever: High-precision R38 WLRGCA2
CA12 Adjustable roller lever: Standard WLRCA2
H12 Adjustable roller lever: General-purpose overtravel model, 80°WLRH2
G12 Adjustable roller lever: High-sensitivity overtravel, 80°WLRG2
CA12-2 Adjustable roller lever: Overtravel, 90°WLRCA2-2
CA12-2N Adjustable roller lever: Overtravel, 90°WLRCA2-2N
CL Adjustable rod lever: Standard, 25 to 140 mm WLRCL
HL
Adjustable rod le ver: General-purpose overt ravel model, 80
°
, 25 to 140 mm
WLRH2
HAL4
Adjustable rod le ver: General-purpose overt ravel model, 80
°
, 350 to 380 mm
WLRH2
GL
Adjustable rod lever: High-sensitivity overtravel, 80
°
, 25 to 140 mm
WLRG2
CL-2 Adjustable rod lever: Overtravel, 90°, 25 to 140 mm WLRCA2-2
CL-2N Adjustable rod lever: Overtravel, 90°, 25 to 140 mm WLRCA2-2N
HAL5 Rod spring lever: General-purpose overtravel model, 80°WLRH2
CA32-41 Fork lever lock: Maintained, WL-5A100 WLRCA32
CA32-42 Fork lever lock: Maintained, WL-5A102 WLRCA32
CA32-43 Fork lever lock: Maintained, WL-5A104 WLRCA32
DPlunger: Top plunger —
D2 Plunger: Top-roller plunger —
D28 Plunger: Sealed top-roller plunger —
D3 Plunger: Top-ball plunger —
SD Plunger: Horizontal plunger —
SD2 Plunger: Horizontal-roller plunger —
SD3 Plunger: Horizontal-ball plunger —
NJ Flexible rod: Coil spring —
NJ-30 Flexible rod: Coil spring, multi-wire —
NJ-2 Flexible rod: Coil spring, resin rod —
NJ-S2 Flexible rod: Steel wire —
Blank
No cables or molding
139
General-purpose built-in switch with cables attached and mold-
ed conduit opening and cover (cover cannot be removed). *
140
Airtight built-in switch with cables attached and molded conduit open-
ing, cover, and box interior cover screws (cover cannot be remov ed). *
141
Airtight built-in switch with cables attached and molded con-
duit opening, cover, head, box interior, cover screws, and
head screws (cover cannot be removed, Head direction can-
not be changed). The Head opening is created to protect it
from cutting powder. *
145
Airtight built-in switch with cables attached and molded conduit
opening, cover, box interior, and cover screws (cover cannot be
removed, Head can be mounted in any of 4 directions). The
Head opening is created to protect it from cutting powder. *
RP40
Airtight built-in switch with cables att ached and molded cover and
box interior (cover cannot be removed, Head direction can be
changed). SC Connector can be removed, so it is possible to use
flexible conduits for the cable. *
RP60
Airtight bu ilt-in switch with cables attached, fluo rine rubber used,
and molded conduit opening, cover, and box interior (cover cannot
be removed, Head direction cannot be changed). *
Symbol Element Voltage Leakage current
Blank No indicator
LE Neon lamp 125 to 250 VAC Approx. 0.6 to 1.9 mA
LD LED 115 VAC/VDC Approx. 0.5 mA
10 to 24 VAC/VDC Approx. 0.4 mA
2NC connection: Light-ON when operating
3NO connection: Light-ON when not operating
Blank Standard lever
ADouble nut lever