NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays FEATURES/BENEFITS * Zero-cross models for resistive loads * Low zero-cross turn-on voltage * Input protection and control LED standard * IP20 touch-proof flaps optional * Connectors for power wiring and heat sinks available * Designed in conformity with EN60947-4-3 (IEC947-4-3) and EN60950/VDE0805 (Reinforced Insulation) With IP20 touch-proof flaps Switch Type STH24D12 12-280 Vac 12A 3-32 Vdc Zero Cross STH24D25 12-280 Vac 25A 3-32 Vdc Zero Cross STH24D35 12-280 Vac 35A 3-32 Vdc Zero Cross STH24D50 12-280 Vac 50A 3-32 Vdc Zero Cross STH48D35 24-600 Vac 35A 3-32 Vdc Zero Cross STH48D50 24-600 Vac 50A 3-32 Vdc Zero Cross STH24D75 24-600 Vac 75A 3-32 Vdc Zero Cross MECHANICAL SPECIFICATION Control Voltage Load Current Load Voltage Part No. Without IP20 touch-proof flaps TYPICAL APPLICATION Figure 2 Figure 1a -- STH relays, up to 25A CONTROL CHARACTERISTICS Figure 1b -- STH relays, 35A and above (c) 2005 TELEDYNE RELAYS (800) 284-7007 * www.teledynerelays.com Figure 3 -- STH relays STH Page 1 STH\032005\Q1 NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays ELECTRICAL SPECIFICATIONS (+25C ambient temperature unless otherwise specified) INPUT (CONTROL) SPECIFICATIONS Min Max Units Input Current Range 10 13 mA Must Turn-Off Voltage 2.0 Vdc Reverse Voltage Protection (R/D) 32 V Clamping Voltage (R/D) 36 V Input Immunity (EN61000-4-4) 2 kV Input Immunity (EN61000-4-5) 2 kV OUTPUT (LOAD) SPECIFICATIONS Min Max Units STH24DXX 600 Vpeak STH48DXX 1200 Vpeak Peak Voltage Load Currrent Range (Resistive) 12 output current .005 12 Arms 25 output current .005 25 Arms 35 output current .005 40 Arms 50 output current .005 60 Arms 75 output current .005 90 Arms Maximum Surge Current Rating (Non-Repetitive) 12 output current 170 A 25 output current 350 A 35 output current 500 A 50 output current 720 A 75 output current 1200 A Zero-Cross Window (Typical) Off-State Leakage Current 35 Vac 1 mA Turn-On Time (60 Hz) 8.3 ms Turn-Off Time (60 Hz) 8.3 ms Off-State dv/dt 500 V/s Maximum di/dt (Non-Repetitive) 50 A/s 800 Hz 12 output current 128 A2s 25 output current 600 A2s 35 output current 1250 A2s 50 output current 2500 A2s 75 output current 7200 A2s 12 output current 2.5 C/W 25 output current 1.7 C/W 35 output current 0.6 C/W 50 output current 0.45 C/W 75 output current 0.4 C/W Operating Frequency 0.1 I2t for fuse matching (<10ms) Junction-Case Thermal Resistance Conducted Immunity Level IEC/EN61000-4-4 (bursts) 2kV criterion B IEC/EN61000-4-5 (surge) 2kV criterion A (with external VDR) On-State Voltage Drop Up to 25 output current 0.85 V Above 35 output current 0.9 V 12 output current 0.9x0.85xI + 0.042xI2 W 25 output current 0.9x0.85xI + 0.016xI2 W 35 output current 0.9x0.9xI + 0.015xI W Output Power Dissipation (Max) 2 50 output current 2 0.9x0.9xI + 0.012xI W 75 output current 0.9x0.9xI + 0.0045xI W STH Page 2 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE (c) 2005 TELEDYNE RELAYS STH\032005\Q1 NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays GENERAL SPECIFICATIONS (+25C ambient temperature unless otherwise specified) SURGE CURRENT Min Max Units Operating Temperature Up to 35 output current -55 +80 C STH24D50 -40 +100 C STH48XXX -40 +80 C ENVIRONMENTAL SPECIFICATIONS Figure 4a -- 12A output current Storage Temperature -55 +125 C STH24D50 -40 +100 C STH48XXX -40 +125 C Up to 35 output current Ambient Humidity 40 to 85 Input-Output Isolation 4000 % Figure 4b -- 25A output current Vrms Up to 25 output current 2500 Vrms Above 35 output current 4000 Vrms Output-Case Isolation 1000 M Rated Impulse Voltage 4000 Protection Level (CEI529) IP20 Vibration (10-55 Hz according to CE168) 1.5 Shock (according to CD168) Housing Material Baseplate 30/50 V mm g Figure 4c -- 35A output current Insulation Resistance @500Vdc PA6 UL94VO Aluminum, nickel-plated Figure 4d -- 50A output current Figure 4e -- 75A output current (c) 2005 TELEDYNE RELAYS (800) 284-7007 * www.teledynerelays.com STH Page 3 STH\032005\Q1 NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays THERMAL CURVES Figure 5c -- 35A output power Figure 5d -- 50A output power Figure 5b -- 25A output power Figure 5a -- 12A output power Figure 5e -- 75A output power 12C/W corresponds to a relay without heat sink 6C/W corresponds to a relay mounted on a DIN-rail adaptor (Teledyne P/N DL12) STH Page 4 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE (c) 2005 TELEDYNE RELAYS STH\032005\Q1 NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays OPTIONAL CONNECTIONS Directly with wires, with or without ferrules With tips (ring terminals) CONTROL WIRING Number of Wires 1 Solid (no ferrule) Screwdriver Type 2 Fine Stranded (with ferrule) Solid (no ferrule) Fine Stranded (with ferrule) Recommended Torque N.m AWG18...AWG14 AWG18...AWG14 AWG18...AWG14 AWG18...AWG14 Pozidriv 2 0.8 Screwdriver Type Recommended Torque POWER WIRING Number of Wires 1 Solid (no ferrule) 2 Fine Stranded (with ferrule) Solid (no ferrule) Fine Stranded (with ferrule) N.m AWG16...AWG8 AWG16...AWG10 AWG16...AWG8 AWG16...AWG10 Power with tips AWG6 16mm2 AWG4 16mm2 W max = 13mm AWG0 50mm2 for high current (c) 2005 TELEDYNE RELAYS Pozidriv 2 1.2 Options TF100 Flap reference without mounting P/N + -16 1 flap (on output) + 1 Teledyne mounting P/N + -17 2 flaps (input & output) + 2 Teledyne mounting Fastons: Call us * Connectors for power wiring and heat sinks available * Designed in conformity with EN60947-4-3 (IEC947-4-3) and EN60950/VDE0805 (Reinforced Insulation) (800) 284-7007 * www.teledynerelays.com STH Page 5 STH\032005\Q1 NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays 2-2.5C/W Teledyne P/N FW151 1.1C/W Teledyne P/N FW108 0.3C/W Teledyne P/N FW031 Mounting HIPpak SSRs must be mounted on heat sinks. A large range of heat sinks is available. For heat-sink mounting, use thermal grease or a thermal pad with high conductibility specified by Teledyne. DIN Rail Adapter Teledyne P/N DL12 Thermal Pad Teledyne P/N -12 Typical Loads STH relays are designed for AC-51 resistive loads (heating). For other loads, consult our selection guide. Protection * To protect the SSR against a short-circuit of the load, use a fuse with a I2t value = 1/2 I2t value specified. EMC Immunity: * Our data sheets list the immunity level of our SSRs according to the main standards for these of products: IEC/EN61000-4-4 and IEC/EN61000-4-5. You can compare the high immunity level with other products on the market. Emission: * Teledyne SSRs are designed in compliance with standards for class A equipment (Industry). * Use of this product in domestic environments may cause radio interference. In this case the user may be required to employ additional devices to reduce noise. SSRs are complex devices that must be interconnected with other equipment (loads, cables, etc.) to form a system. Because the other equipment or interconnections may not be under Teledyne's control, it shall be the responsibility of the system integrator to ensure that systems containing SSRs comply with the requirement of any rules and regulations applicable at the system level. STH Page 6 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE (c) 2005 TELEDYNE RELAYS STH\032005\Q1