110 WATTS REL-110 SINGLE/MULTI OUTPUT AC-DC OUTPUT SPECIFICATIONS Total Output Power at 50C(1) (See Derating Chart) Output Voltage Centering FEATURES: * * * * * * Compact 3" x 5" x 1.3" Size 2 Year Warranty Universal 85-264V Input One to Four Outputs High Efficiency 0-70C Operating Temperature CHASSIS/COVER * * * * * * IEC 60601-1 3rd ed. Medical Cert. IEC 60950-1 2nd ed. ITE Certification IEC 60601-1-2 4th ed. EMC Class B Emissions per EN55011/32 RoHS Compliant Optional Chassis/Cover OPEN FRAME SAFETY SPECIFICATIONS Underwriters Laboratories File E137708/E140259 UL Recognition Mark for Canada File E137708/E140259 UL 60950-1:2007, 2nd Edition AAMI/ANSI ES60601-1:2005/(R) 2012 CB Reports/Certificates (including all National and Group Deviations) IEC 62368-1:2014, 2nd Edition IEC 60601-1:2005/A1:2012 CAN/CSA-C22.2 No. 60950-1-07, 2nd Edition CAN/CSA-C22.2 No. 60601-1:2014 2nd TUV EN 62368-1:2014, Edition EN 60601-1:2006/A1:2013 Low Voltage Directive RoHS Directive (Recast) (2014/35/EU of February 2014) (2011/65/EU of June 2011) MODEL LISTING MODEL OUTPUT 1(21) OUTPUT 2(21) OUTPUT 3(20) OUTPUT 4(20) REL-110-4001 REL-110-4002 REL-110-4003 REL-110-4004 REL-110-4005 REL-110-4006 REL-110-4007 REL-110-4009 REL-110-3001 REL-110-3002 REL-110-3003 REL-110-3004 REL-110-2001 REL-110-2002 REL-110-2003 REL-110-2004 REL-110-2005 REL-110-2006 REL-110-1001 REL-110-1002 REL-110-1003 REL-110-1004 REL-110-1005 REL-110-1006 REL-110-1007 REL-110-1008 +3.3V/10A(22) +5V/10A(22) +5V/10A(22) +5V/10A(22) +5V/10A(22) +5V/10A(22) +5V/10A(22) +5V/10A(22) +5V/10A(22) +5V/10A(22) +8V/6A +9V/3A +3.3V/10A(22) +5V/10A(22) +5V/10A(22) +12V/5A +15V/4A +18V/4A 2.5V/22A(23) 3.3V/22A(23) 5V/22A(23) 12V/9.2A 15V/7.3A 24V/4.6A 28V/3.9A 48V/2.3A +5V/6A +3.3V/6A +3.3V/6A -5V/6A -5V/6A +24V/2A +24V/2A +24V/2A +12V/3A +15V/2A -8V/1A -24V/3A +5V/6A +12V/5A +24V/3A -12V/4A -15V/3A -18V/3A +12V/2A +12V/2A +15V/2A +12V/2A +15V/2A +12V/2A +15V/2A +7V/2.5A +13V/2A ORDERING INFORMATION Consult factory for alternate output configurations. Consult factory for positive, negative or floating outputs. Please specify the following optional features when ordering: CH - Chassis CO - Cover I/O - Isolated Outputs TS - Terminal Strip -12V/2A -12V/2A -15V/2A -12V/2A -15V/2A -12V/2A -15V/2A -7V/2.5A -12V/3A -15V/2A +30V/1A Output Voltage Adjust Range Load Regulation Source Regulation Cross Regulation Output Noise Turn on Overshoot Transient Response Voltage Deviation Recovery Time Load Change Output Overvoltage Protection Output Overpower Protection Hold Up Time Start Up Time 80W Convection Cooled(16)(18) 110W 300LFM Forced-Air Cooled(15)(17)(19) Output 1: 0.5% (All outputs Output 2: at 50% load) 5.0% Output 3: 5.0% Output 4: 5.0% Output 1: 95-105% Output 1: 0.5% (10-100% load change) Output 2: 5.0% (4001-5 Models) 8.0% (2001 Model) 6.0% Output 3: 5.0% Output 4: 5.0% Outputs 1 - 4: 0.5% Outputs 2 - 4: 5.0% Outputs 1 - 4: 1.0% None Outputs 1 - 4 5.0% 500S 50% to 100% Output 1: 110% to 150% 110-160% rated Pout, cycle on/off, auto recovery 16mS min., Full Power, 85V Input 4 Seconds, 120V Input INPUT SPECIFICATIONS Protection Class Source Voltage Frequency Range Peak Inrush Current Efficiency Power Factor I 85 - 264 Volts AC 47 - 63 Hz 40A 82% Typ., Full Power, 230V, varies by model 0.95 (Full Power, 230V) ENVIRONMENTAL SPECIFICATIONS Ambient Operating Temperature Range Ambient Storage Temp. Range Temperature Coefficient 0C to + 70C Derating: See Power Rating Chart - 40C to + 85C Outputs 1 - 4: 0.02%/C GENERAL SPECIFICATIONS Means of Protection Primary to Secondary Primary to Ground Secondary to Ground Dielectric Strength(8, 9) Reinforced Insulation Basic Insulation Operational Insulation Leakage Current Earth Leakage Touch Current Power Fail Signal(14) Remote Sense (singles only)(10) Mean-Time Between Failures Weight 2MOPP (Means of Patient Protection) 1MOPP (Means of Patient Protection) Operational Insulation(Consult factory for 1MOOP or 1MOPP) 5656 VDC, Primary to Secondary 2121 VDC, Primary to Ground 707 VDC, Secondary to Ground <300A NC, <1000A SFC <100A NC, <500A SFC Logic low with input power failure 10 ms minimum prior to Output 1 dropping 1% 250mV compensation of output cable losses 100,000 Hours min., MIL-HDBK-217F, 25 C, GB 0.80 Lbs. Open Frame/ 1.28 Lbs. Chassis and Cover EMC SPECIFICATIONS (IEC 60601-1-2:2014, 4TH ed./IEC 61000-6-2:2005) Electrostatic Discharge Radiated Electromagnetic Field Electrical Fast Transients/Bursts Surge Immunity Conducted Immunity Magnetic Field Immunity Voltage Dips EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-8 EN 61000-4-11 Voltage Interruptions Radiated Emissions Conducted Emissions Harmonic Current Emissions Voltage Fluctuations/Flicker EN 61000-4-11 EN 55011/32 EN 55011/32 EN 61000-3-2 EN 61000-3-3 8KV contact / 15KV air discharge A 80MHz-2.7GHz, 10V/m, 80% AM A 2 KV, 5KHz/100KHz A 2 KV line to earth / 1 KV line to line A 0.15 to 80MHz, 10V, 80% AM A 30A/m, 60 Hz. A 0% UT, 0.5 cycles, 0-315 100/240V A/A 0% UT, 1 cycles, 0 100/240V A/A 40% UT, 10/12 cycles, 0 100/240V B/A 70% UT, 25/30 cycles, 0 100/240V B/A 0% UT, 300 cycles, 0 100/240V B/B Class B Class B Class A Compliant All specifications are maximum at 25 C, 110W unless otherwise stated, may vary by model and are subject to change without notice. INTEGRATED POWER DESIGNS 300 Stewart Road Wilkes-Barre, PA 18706 Phone: (570) 824-4666 Fax: (570) 824-4843 Email: sales@ipdpower.com Web: www.ipdpower.com REL-110 SERIES MECHANICAL SPECIFICATIONS APPLICATIONS INFORMATION 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. Each output can deliver its rated current but Total Output Power must not exceed 110W, as determined by the cooling method. Generally, adequate cooling is provided when semiconductor case temperatures do not exceed 70C rise and transformer temperature does not exceed 60C rise at any specified ambient temperature. Sufficient area must be provided around power supply to allow natural movement of air to develop in convection-cooled applications. This product is intended for use as a professionally-installed component within information technology, industrial, and medical equipment and is not intended for stand-alone operation. A minimum load of 10% is required on Output 1 to ensure proper regulation of remaining outputs. This product includes only one fuse in the input circuit. In consideration of Clause 8.11.5 of IEC 60601-1:2005, a second fuse may be required in neutral conductor of the end product. Peak-to-Peak Output Ripple and Noise is measured directly at the output terminals of the power supply, without the use of the probe ground lead or retractable tip (tip-and-barrel method), 20 MHz bandwidth. This product was type-tested and safety-certified using the dielectric strength test voltages listed in Table 6 of IEC 60601-1:2005. In consideration of Clause 8.8.3, care must be taken to insure that the voltage applied to a reinforced insulation does not overstress different types and levels of insulation. Primary and secondary-to-ground capacitors may need to be disconnected prior to performing a dielectric strength test on the power supply or the end product. It is highly recommended that the DC test voltages listed in DVB.1, Annex DVB of UL 60601-1 1st Edition are not exceeded during a production-line dielectric strength test of the assembled end product. Please consult factory for further information. This power supply has been safety-approved and final-tested using a DC dielectric strength test. Please consult factory before performing an AC dielectric strength test. Remote-Sense terminals may be used to compensate for cable losses up to 250mV (single-output models only). The use of a twisted pair, decoupling capacitors and an appropriately-rated low-impedance capacitor connected across the load will increase noise immunity. Maximum screw penetration into bottom chassis mounting holes is 0.100 inches. Maximum screw penetration into side chassis mounting holes is 0.250 inches. To comply with emissions specifications, all four mounting hole pads must be electrically connected to a common metal chassis. Chassis/Cover option is recommended. Refer to Operating Instructions for additional information. Common RF shielding precautions may need to be taken to assure emissions compliance. Refer to Operating Instructions for additional information. Power-Fail (AC-Good) feature provides a logic-low warning signal from an open collector transistor output 10ms prior to loss of output from AC failure, 5V/10mA. 300LFM minimum of airflow must be maintained one inch above all points of top-side components or cover when forced-air cooling is required. Total power must not exceed 80W with convection cooling on open-frame models except where noted. Total power must not exceed 110W with 300LFM forced-air cooling on open-frame models. Total power must not exceed 65W with convection cooling and Chassis/Cover option. Total power must not exceed 110W with 300LFM forced-air cooling and Chassis/Cover option. Total current from Outputs 3 & 4 must not exceed 3A with convection cooling. Total current from Outputs 1 & 2 must not exceed 12A with convection cooling. Rated 8A maximum with convection cooling. Rated 16A maximum with convection cooling. Output Power (Watts) MAXIMUM OUTPUT POWER vs. AMBIENT TEMPERATURE 110 100 90 80 70 60 50 40 30 20 10 0 F O R C E D AI R C O N V E C T I O N C O O L I N G C O O L I N G CO NV E CTI ON CO O L I NG W I TH CHAS S I S / CO V ER 0 10 20 30 40 50 60 70 Ambient Temperature (C) CONNECTOR SPECIFICATIONS AC Input P2 DC Output (Single) P2 DC Output (Multiple) G P3 Ground P.F./Sense (Single) P3 P.F. (Multiple) 0.156 friction lock header mates with Tyco 640250-3 or equivalent crimp terminal housing with Tyco 3-640706-1 or equivalent crimp terminal. 0.156 friction lock header mates with Tyco 770849-8 or equivalent crimp terminal housing with Tyco 3-640707-1 or equivalent crimp terminal. 0.156 friction lock header mates with Tyco 1-770849-0 or equivalent crimp terminal housing with Tyco 3-640707-1 or equivalent crimp terminal. 0.187 quick disconnect terminal. 0.100 breakaway header mates with Molex 50-57-9006 or equivalent crimp terminal housing with Molex type 71851 or equivalent crimp terminal. 0.100 breakaway header mates with Molex 50-57-9002 or equivalent crimp terminal housing with Molex type 71851 or equivalent crimp terminal. INTEGRATED POWER DESIGNS 300 Stewart Road Wilkes-Barre, PA 18706 Phone: (570) 824-4666 Fax: (570) 824-4843 Email: sales@ipdpower.com Web: www.ipdpower.com REV.Q 03/20/2019 P1