3VA1102-5MG36-0AA0.pdf10 Pages, 7807 KB, Original
3VA1102-5MG36-0AA0
Siemens
MCCB_IEC_FS160_2A_3P_55KA_TM_ FM

Product Details Search Results:

Siemens.com/3VA1010-2ED36-0AA0
Circuit breaker 3VA1 IEC Frame 100 Switching capacity class B Icu=16 kA @ 415 V 3-pole, system protection TM210, FTFM, In=100 A Overload protection Ir=100 A non-adjustable short-circuit protection Ii = 10 x In Terminal connection Model Product brand name SENTRON Product designation Molded case circuit breaker Product version Line protection Design of the overcurrent release TM210 Protective function of the overcurrent release LI Number of poles 3 General technical data Rated insulation voltage Ui 800\u00a0V...
7613 Bytes - 17:20:48, 03 January 2025
Siemens.com/3VA1032-2ED36-0AA0
circuit breaker 3VA1 IEC frame 100 breaking capacity class B Icu=16kA @ 415V 3-pole, line protection TM210, FTFM, In=32A overload protection Ir=32A fixed short-circuit protection Ii=10 x In clamp connection Model Product brand name SENTRON Product designation Molded case circuit breaker Product version Line protection Design of the overcurrent release TM210 Protective function of the overcurrent release LI Number of poles 3 General technical data Rated insulation voltage Ui 800\u00a0V Max. rated operational...
7683 Bytes - 17:20:48, 03 January 2025
Siemens.com/3VA1050-2ED36-0AA0
circuit breaker 3VA1 IEC frame 100 breaking capacity class B Icu=16kA @ 415V 3-pole, line protection TM210, FTFM, In=50A overload protection Ir=50A fixed short-circuit protection Ii=10 x In clamp connection Model Product brand name SENTRON Product designation Molded case circuit breaker Product version Line protection Design of the overcurrent release TM210 Protective function of the overcurrent release LI Number of poles 3 General technical data Rated insulation voltage Ui 800\u00a0V Max. rated operational...
7571 Bytes - 17:20:48, 03 January 2025
Siemens.com/3VA1063-2ED36-0AA0
circuit breaker 3VA1 IEC frame 100 breaking capacity class B Icu=16kA @ 415V 3-pole, line protection TM210, FTFM, In=63A overload protection Ir=63A fixed short-circuit protection Ii=10 x In clamp connection Model Product brand name SENTRON Product designation Molded case circuit breaker Product version Line protection Design of the overcurrent release TM210 Protective function of the overcurrent release LI Number of poles 3 General technical data Rated insulation voltage Ui 800\u00a0V Max. rated operational...
7680 Bytes - 17:20:48, 03 January 2025
Siemens.com/3VA1063-3ED36-0AA0
circuit breaker 3VA1 IEC frame 100 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM210, FTFM, In=63A overload protection Ir=63A fixed short-circuit protection Ii=10 x In clamp connection Model Product brand name SENTRON Product designation Molded case circuit breaker Product version Line protection Design of the overcurrent release TM210 Protective function of the overcurrent release LI Number of poles 3 General technical data Rated insulation voltage Ui 800\u00a0V Max. rated operational...
7543 Bytes - 17:20:48, 03 January 2025
Siemens.com/3VA1080-2ED36-0AA0
circuit breaker 3VA1 IEC frame 100 breaking capacity class B Icu=16kA @ 415V 3-pole, line protection TM210, FTFM, In=80A overload protection Ir=80A fixed short-circuit protection Ii=10 x In clamp connection Model Product brand name SENTRON Product designation Molded case circuit breaker Product version Line protection Design of the overcurrent release TM210 Protective function of the overcurrent release LI Number of poles 3 General technical data Rated insulation voltage Ui 800\u00a0V Max. rated operational...
7572 Bytes - 17:20:48, 03 January 2025
Siemens.com/3VA1080-3ED36-0AA0
circuit breaker 3VA1 IEC frame 100 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM210, FTFM, In=80A overload protection Ir=80A fixed short-circuit protection Ii=10 x In clamp connection Model Product brand name SENTRON Product designation Molded case circuit breaker Product version Line protection Design of the overcurrent release TM210 Protective function of the overcurrent release LI Number of poles 3 General technical data Rated insulation voltage Ui 800\u00a0V Max. rated operational...
7680 Bytes - 17:20:48, 03 January 2025
Siemens.com/3VA1110-1AA36-0AA0
switch disconnector 3VA1 IEC frame 160 3-pole SD100, In=100A without overload protection w/o short-circuit protection clamp connection Model Product brand name SENTRON Product designation Switch disconnector Product version in MCCB design Number of poles 3 Design of the auxiliary release without Auxiliary contact version Without General technical data Rated insulation voltage Ui 800\u00a0V Max. rated operational voltage Ue with AC 50/60Hz 690\u00a0V Max. rated operational voltage Ue with DC 500\u00a0V Power...
4351 Bytes - 17:20:48, 03 January 2025
Siemens.com/3VA1110-5EE36-0AA0
circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM220, ATFM, In=100A overload protection Ir=70A...100A short-circuit protection Ii=10 x In clamp connection Model Product brand name SENTRON Product designation Molded case circuit breaker Product version Line protection Design of the overcurrent release TM220 Protective function of the overcurrent release LI Number of poles 3 General technical data Rated insulation voltage Ui 800\u00a0V Max. rated operation...
7704 Bytes - 17:20:48, 03 January 2025
Siemens.com/3VA1110-5EF36-0AA0
circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=100A overload protection Ir=70A...100A short-circuit protection Ii=5...10 x In clamp connection Model Product brand name SENTRON Product designation Molded case circuit breaker Product version Line protection Design of the overcurrent release TM240 Protective function of the overcurrent release LI Number of poles 3 General technical data Rated insulation voltage Ui 800\u00a0V Max. rated opera...
7701 Bytes - 17:20:48, 03 January 2025
Siemens.com/3VA1112-3EF36-0AA0
circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection Model Product brand name SENTRON Product designation Molded case circuit breaker Product version Line protection Design of the overcurrent release TM240 Protective function of the overcurrent release LI Number of poles 3 General technical data Rated insulation voltage Ui 800\u00a0V Max. rated opera...
7705 Bytes - 17:20:48, 03 January 2025
Siemens.com/3VA1112-5EF36-0AA0
circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=5...10 x In clamp connection Model Product brand name SENTRON Product designation Molded case circuit breaker Product version Line protection Design of the overcurrent release TM240 Protective function of the overcurrent release LI Number of poles 3 General technical data Rated insulation voltage Ui 800\u00a0V Max. rated opera...
7707 Bytes - 17:20:48, 03 January 2025