Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
NC
ASCTB12E 201203-T
2) Single side stable (DC)
* At 20°C 68°F (Amber type)
2. Specifications
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. 100V DC: 740mW
*3. For the AC type, the operate and release time differs depending on the phase of the input and cutoff times.
*4. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*5. 100V DC: –40°C to +40°C –40°F to +104°F
No. of
poles
Nominal
coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal operating
current [±10%]
(at 20°C 68°F)
Coil resistance
[±10%]
(at 20°C 68°F)
Nominal operating
power
Coil inductance Max. applied
voltage
(at 50°C 122°F)*
N.C.
condition
N.O.
condition
2 Form C
3V DC
80%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
120mA 25Ω360mW 24.2mH 30.0mH
135%V of
nominal voltage
5V DC 72mA 69.4Ω360mW 69.5mH 86.0mH
6V DC 60mA 100Ω360mW 99.4mH 123mH
12V DC 30mA 400Ω360mW 388mH 480mH
24V DC 15mA 1,600Ω360mW 1,590mH 1,970mH
48V DC 7.5mA 6,400Ω360mW 6,270mH 7,680mH
100V DC 7.4mA 13,500Ω740mW 9,470mH 11,700mH 110%V of
nominal voltage
4 Form C
3V DC
80%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
240mA 12.5Ω720mW 12.8mH 15.8mH
110%V of
nominal voltage
5V DC 144mA 34.7Ω720mW 34.3mH 42.4mH
6V DC 120mA 50Ω720mW 50.7mH 62.7mH
12V DC 60mA 200Ω720mW 203mH 252mH
24V DC 30mA 800Ω720mW 812mH 1,000mH
48V DC 15mA 3,200Ω720mW 2,820mH 3,480mH
100V DC 7.4mA 13,500Ω740mW 14,100mH 17,400mH
Characteristics Item
Specifications
DC AC DC AC
Single side stable Single side stable Single side stable Single side stable
Contact
Arrangement 2 Form C 4 Form C
Contact resistance (Initial) Max. 50 mΩ (By voltage drop 6 V DC 1A) Max. 50 mΩ (By voltage drop 6 V DC 1A)
Contact material Au-clad AgNi type Au-clad AgNi type
Rating
Nominal switching capacity
(resistive load)
Standard: 5A 250V AC, 5A 30V DC
Amber: 3A 250V AC, 5A 30V DC
Standard: 4A 250V AC, 5A 30V DC
Amber: 2A 250V AC, 5A 30V DC
Max. switching power
(resistive load)
Standard: 1,250VA, 150W
Amber: 750VA, 150W
Standard: 1,000VA, 150W
Amber: 500VA, 150W
Max. switching voltage 250 V AC
Max. switching current Standard: 5A
Amber: 3A (AC), 5A (DC)
Standard: 4A
Amber: 2A (AC), 5A (DC)
Nominal operating power 360mW (740mW: 100V DC) 0.50VA to 1.05VA 720mW*21.08VA to 1.30VA
Min. switching capacity
(Reference value)*1100µA 1V DC 100µA 1VDC
Electrical
characteristics
Insulation resistance (Initial) Min. 100MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown
voltage
(Initial)
Between open
contacts 1,000 Vrms for 1min. (Detection current: 10mA.)
Between
contact sets 1,000 Vrms for 1min. (Detection current: 10mA.)
Between
contact and coil 2,000 Vrms for 1min. (Detection current: 10mA.)
Temperature rise (coil) Max. 65°C [Max. 85°C (100V AC)] (By resistive method, nominal coil voltage)
Operate time (at 20°C 68°F) Max. 20ms Max. 30ms*3Max. 20ms Max. 30ms*3
Release time (at 20°C 68°F) Max. 10ms Max. 40ms*3Max. 10ms Max. 40ms*3
Mechanical
characteristics
Shock
resistance
Functional Min. 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Destructive Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Vibration
resistance
Functional 10 to 55 Hz at double amplitude of 1 mm (Detection time: 10µs.)
Destructive 10 to 55 Hz at double amplitude of 2 mm
Expected life
Mechanical Min. 5×107Min. 107Min. 5×107Min. 107
Electrical (resistive load) Standard: Min. 105 (5A 250V AC), Min. 5×105 (5A 30V DC)
Amber: Min. 105 (3A 250V AC), Min. 5×105 (5A 30V DC)
Standard: Min. 105 (4A 250V AC), Min. 5×105 (5A 30V DC)
Amber: Min. 105 (2A 250V AC), Min. 5×105 (5A 30V DC)
Conditions
Conditions for operation,
transport and storage*4
(Not freezing and condensing
at low temperature)
–40°C to +70°C
–40°F to +158°F
(Max.48V DC),
–40°C to +55°C
–40°F to +131°F (100V DC)
–40°C to +60°C
–40°F to +140°F*5
–40°C to +55°C
–40°F to +131°F
–40°C to +40°C
–40°F to +104°F
Max. Operating speed 50 cps