INTEGRATED CIRCUITS DIVISION
www.ixysic.com
DS-LAA125-R06 1
LAA125
Dual Single-Pole, Normally Open
OptoMOS® Relays
e3
Pb
Part # Description
LAA125 8 Pin DIP (50/Tube)
LAA125S 8 Pin Surface Mount (50/Tube)
LAA125STR 8 Pin Surface Mount (1,000/Reel)
LAA125P 8 Pin Flat Pack (50/Tube)
LAA125PTR 8 Pin Flat Pack (1,000/Reel)
Parameter Ratings Units
Blocking Voltage 350 VP
Load Current 170 mArms / mADC
On-Resistance (max) 16
Applications
Features
Description
Approvals
Ordering Information
Pin Configuration
Switching Characteristics of
Normally Open (Form A) Devices
• 3750Vrms Input/Output Isolation
• Low Drive Power Requirements (TTL/CMOS
Compatible)
• No Moving Parts
• High Reliability
• Arc-Free With No Snubbing Circuits
• FCC Compatible
• VDE Compatible
• No EMI/RFI Generation
• Small 8-Pin Packages
• Machine Insertable, Wave Solderable
• Surface Mount and Tape & Reel Versions Available
• Telecommunications
• Telecom Switching
• Tip/Ring Circuits
• Modem Switching (Laptop, Notebook,
Pocket Size)
• Hook Switch
• Dial Pulsing
• Ground Start
• Ringing Injection
• Instrumentation
• Multiplexers
• Data Acquisition
• Electronic Switching
• I/O Subsystems
• Meters (Watt-Hour, Water, Gas)
• Medical Equipment-Patient/Equipment Isolation
• Security
• Aerospace
• Industrial Controls
LAA125 is a 350V, 170mA, 16 dual normally open
(1-Form-A) relay. It combines enhanced peak load
current capability with low on-resistance. Its MOSFET
switches and photovoltaic die provide 3750Vrms of
input to output isolation.
The optically coupled outputs, that use patented
OptoMOS architecture, are controlled by a highly
efficient GaAIAs infrared LED.
This dual switch OptoMOS relay provides a more
compact design solution than discrete single-pole
relays in a variety of applications, and saves board
space by incorporating two switches in a single 8-pin
package.
• UL Recognized Component: File E76270
• CSA Certified Component: Certificate 1175739
• EN/IEC 60950-1 Certified Component:
TUV Certificate B 09 07 49410 004
1
2
3
4
8
7
6
5
+ Control - Switch #1
- Control - Switch #1
+ Control - Switch #2
- Control - Switch #2
Load - Switch #1
Load - Switch #1
Load - Switch #2
Load - Switch #2
Form-A
IF
ILOAD
10%
90%
ton toff