Approx. 400mW
Features
110 77.0 11.0
HONGFA RELAY
Coil power
25200 x (1 15%)
VDE
Shock resistance *
Dielectric
strength
Plastic sealed,
Flux proofed
ISO9001, ISO/TS16949 , ISO14001, OHSAS18001, IECQ QC 080000 CERTIFIED 2018 Rev. 1.00
190
16A 250VAC at 85°C
Incandescent lamp 3000W 230VAC
TV-8 120VAC
Incandescent lamp 1200W 120VAC at 50°C
Incandescent lamp 1200W 277VAC at 50°C
Standard ballast 2.2A 277VAC at 50°C
Electronic ballast 16A 277/120VAC 85°C
Electronic ballast 12A 277/120VAC 85°C
Electronic ballast 8A 277/347VAC 85°C
Electronic ballast 15A 120VAC 85°C3)
Electronic ballast 8A 277/347VAC 85°C3)
File No.:116934
File No.:CQC17002168381
File No.:E134517
UL/CUL
HF115F-S
1A
100m max.(at 1A 6VDC)
W+AgSnO2
Resistive:16A 250VAC
Contact arrangement
Contact resistance
Contact material
5000VAC 1min
1250VAC 1min
10kV (1.2 / 50µs)
10ms max.
5ms max.
55K max.
98m/s2
980m/s2
10Hz to 150Hz 10g
5% to 85% RH
-40 to 85
PCB
Approx. 13.5g
MINIATURE HIGH POWER RELAY
CONTACT DATA
CHARACTERISTICS
COIL
Nominal
Voltage
VDC
Coil
Resistance
Pick-up
Voltage
VDC
max.
Drop-out
Voltage
VDC
min.
COIL DATA
5
6
12
24
48
60
3.50
4.20
8.40
16.8
33.6
42.0
0.5
0.6
1.2
2.4
4.8
6.0
SAFETY APPROVAL RATINGS
Insulation resistance
Between coil & contacts
Between open contacts
Surge voltage (between coil & contacts)
Operate time (at nomi. volt.)
Release time (at nomi. volt.)
Temperature rise (at nomi. volt.)
Functional
Destructive
62 x (1 10%)
90 x (1 10%)
360 x (1 10%)
1440 x (1 10%)
5760 x (1 15%)
7500 x (1 15%)
96.30 0.9 202 x (1 10%)
18 12.6 1.8 810 x (1 10%)
7.5
9.0
18
36
72
90
165
13.5
27
Max.
Voltage
VDC
● Special contact struction
● Incandescent lamp load: 3000W 230VAC
● 5kV dielectric strength (between coil and contacts)
● Creepage distance: 11mm
● Low height: 15.7 mm
● Meeting reinforce insulation
● Product in accordance to IEC 60335-1 available
● Plastic sealed and flux proofed types available
● UL insulation system:Class F available
● Environmental friendly product (RoHS compliant)
● Outline Dimensions: 29.0mm x 12.7mm x 15.7mm
1000M (at 500VDC)
Construction
at 23
2) Maximum voltage refers to the maximum voltage which relay
coil could endure in a short period of time.
Contact rating
Notes:1) This contact resistance value is tested under the norminal
voltage.
2) * Index is not that of relay length direction.
3) The data shown above are initial values.
4) UL insulation system: Class F, Class B.
V
DE
Notes:1) The data shown above are initial values.
Notes:1) The data shown above are initial values.
Vibration resistance *
Humidity
Ambient temperature
Termination
Unit weight
Electrical endurance
Notes: 1) All values unspecified are at room temperature.
2) Only typical loads are listed above. Other load specifications
can be available upon request.
3) Zero crossing control cooperative.
1.2 x 104OPS (3000W 230VAC,
Incand escentlamp load, Room temp.,
1s on 11s off)
Incandescent Lamp: 3000W 230VAC
Inrush current: 165A / 20ms
LED(Electronic ballast): 492A/1.5ms
Max. switching power
Mechanical endurance
Max. switching voltage
Max. switching current 440VAC
16A
4000VA
5 x 106OPS
3) For products with rated voltage ≥ 48V, measures should be
taken to prevent coil overvoltage in order to protect coil in test
and application (eg. Connect diodes in parallel).
3)
3)
2)
3)
16A 250VAC at 85°C
1)
1) 1)