Main features
Range of measurement: from 100 N to 1kN
Accuracy class: 0,5%
Corrosion resistant
Internally generated calibration signal
Orientation of the axis of maximum sensitivity for 35°
independently from the position of the fixing holes
Grade of protection: IP65 (DIN 40050)
Integrated protection against overloads
TR series force transducers are used to measure the tension
that plastic films or tapes exert on the guide rollers of the
machinery used to coil them.
Mounted at the ends of a fixed or transmission shaft on the
machine chassis, they perform the function of force sensors
and bearing for the ends of the shaft.
They are used on both fixed and rotating shafts.
TR transducers are supplied with the adaptor flange for fixing,
with 4 M6 screws or with one central M10 or M12 screw.
FLA705 Std Flange
4 seats for M6 fixing screws
of the cover
VPT02A10-6PT2
CONNECTOR
Direction of the axis of max.
sensitivity of the load cell
(Indicated by a red dot on the
bearing support).
N° 4 M6 case screws to
prevent the bearing support
from rotating.
Neoprene
Sleeve
Bearing
35x15 H11
40x17 H12
B
14,5
14,25
øC
35
40
øD
20
30
E
1,6
1,85
TECHNICAL DATA
0,5%
100N...1kN
2mV/V
1% FSO
< ± 0,5% FSO
< ± 0,06% FSO
< ± 1% FSO
< ± 0,005% FSO°C
< ± 0,01% FSO°C
-
350 Ohm
> 10 GOhm
10V
15 V
-10...+50°C
-20...+60°C
-30...+80°C
100% Ln
300% Ln
> 500% Ln
150% Ln
< 0,5 mm
IP65
VPT02A10-6PT2
Anodised aluminium
Anodised aluminium
(Flange and bearing
in AISI 303)
Accuracy
Nominal full scale load (Ln)
Nominal output at FSO
Output tolerance at Ln
Combined errors: Non linearity
Histeresis, Repeatibility
Creep (after 30 min. at Ln)
Zero load out of balance signal
Thermal drift in Sensitivity
compensated Zero
range Calibration
Nominal bridge resistance
Isolation resistance
Nominal supply voltage
Maximum supply voltage
Compensated temperature range
Maximum temperature range
Storage temperature range
Permitted static load
Maximum applicable load
Rupture load
Maximum static lateral load
Maximum elastic deformation at Ln
Grade of protection (DIN40050)
Electr. connections: Connector
Elastic element material
Case material
FLA705 Std Flange
4 seats for M6 fixing screws
of the cover
VPT02A10-6PT2
CONNECTOR
Moving Half-shell Fixed Half-shell
Direction of the axis of max.
sensitivity of the load cell
(Indicated by a red dot on the
bearing support).
N° 4 M6x20 screws for
tightenning the half shells
of the fixed hub support.
N° 4 M6 case screws to
prevent the bearing support
from rotating.
Neoprene
Sleeve
Model for
rollers with
revolving hub.
Model for
rollers with
fixed hub.
øA
37
42,5
Dimensions mm. (± 0,1)
Recommended torque for M6 fixing screws: 7Nm
LEADER Electronic Co., Ltd
116, Jianghuali, Jianghua Road, Jiangmen City, GD, PRC
Tel: + 86 750 3101711, 3379183
Fax: + 86 750 3388669
Website: www.leadersensors.com
E-mail: leader@leadersensors.com cod. 84723 - 10/99
GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice.
UNI EN 29001 - ISO 9001
Certificato nr. 9115.GEF1
ELECTRICAL CONNECTIONS
CONVERSION TABLE
ORDER CODE
If the transducer is
supplied complete with
prewired connection
cable, the colour code is
that indicated in the table.
VPT02A10-6PT2
CONNECTOR
Ex.: TR-N3.5C-C40-1
TR force transducer, measurement range 350N,
external bearing diameter of 40mm with normal
mounting and standard flange.
FLANGE
FLA 705 (standard) 1
EXTERNAL DIAMETER
40 mm bearing C40
If request, it is possible to sup-
ply models with non-standard
mechanical and/or electrical
features.
Force transducer TR
0 - 500 N5C
0 - 350 N3.5C
MEASUREMENT RANGE (N)
0 - 100
0 - 200 N1C
N2C
0 - 750 N7.5C
30 mm shaft spindle P30
35 mm bearing
Cells connected in parallel
In systems that use several cells, the parallel
connection automatically sums the loads on each
individual cell.
Using this method of measurement, the maximum load
will be the sum of the loads on the individual cells and
the sensitivity will be the average value of these cells.
It is important that the user ensures that no cell is
stessed beyond its maximum rating under any load
condition.
Kg
1
0.102
0.454
N
9.807
1
4.448
Lb
2.205
0.225
1
FLANGE
SIGNAL
EXCITATION
CABLE
OUTPUT CABLE
CONNECTION
Red
Yellow or Black
White
Green
SIGNAL
EXCITATION
Standard adaptor flange (see mechanical
dimensions drawing) FLA705
Central fixing FLA711
Central fixing FLA715
*Recommended torque 75Nm
OPTIONAL ACCESSORIES
Radial bearing with stop ring (UNI7437-75)
and spacer 35 mm PKIT 602
40 mm PKIT 600
Female cable connector
Grade of protection IP65 CON 300
TR application manual DOC467
0 - 1000 N1M
C35
FLA711 2
FLA715 3
SEAT FOR M10* FIXING
SCREW OF THE COVER
4 SEATS FOR M6 FIXING
SCREW OF THE SUPPORT
SEAT FOR M12* FIXING
SCREW OF THE LOAD CELL TO CARTER
4 SEATS FOR M6 FIXING
SCREW OF THE SUPPORT
Red
Yellow or Black
White
Green
Yellow-Green
Red
Yellow or Black
White
Green
Yellow-Green
SHUNT BOX
FLA711 FLA715