General-purpose Relay MY New model 1
General-purpose Relay
MY New model
Versatile and Function-filled Miniature Power
Relay for Sequence Control and Power
Switching Applications
Models with lockable test buttons now available.
Many variations possible through a selection of operation indi-
cators (mechanical and LED indicators), lockable test button,
built-in diode and CR (surge suppression), bifurcated contacts,
etc.
Arc barrier standard on 4-pole Relays.
Dielectric strength: 2,000 VAC (coil to contact)
Environment-friendly cadmium-free contacts.
Safety standard approvals obtained.
Wide range of Sockets (PY, PYF Series) and optional parts are
available.
Max. Switching Current: 2-pole: 10 A, 4-pole: 5 A
Provided with nameplate.
LR
Ordering Information
Relays
Standard Coil Polarity
Reverse Coil Polarity
Note: When ordering, add the rated coil voltage and (s) to the model number. Rated coil voltages are given in the coil ratings table.
Type Contact form Plug-in socket/Solder terminals Without LED indicator
Standard with LED indicator With LED indicator and
lockable test button
Standard DPDT MY2N MY2IN MY2
4PDT MY4N MY4IN MY4
4PDT (bifurcated) MY4ZN MY4ZIN MY4Z
With built-in diode
(DC only) DPDT MY2N-D2 MY2IN-D2 ---
4PDT MY4N-D2 MY4IN-D2 ---
4PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 ---
With built-in CR
(220/240 VAC, 110/120 VAC
only)
DPDT MY2N-CR MY2IN-CR ---
4PDT MY4N-CR MY4IN-CR ---
4PDT (bifurcated) MY4ZN-CR MY4ZIN-CR ---
Type Contact form Plug-in socket/Solder terminals
With LED indicator With LED indicator and
lockable test button
Standard (DC only) DPDT MY2N1 MY2IN1
4PDT MY4N1 MY4IN1
4PDT (bifurcated) MY4ZN1 MY4ZIN1
With built-in diode
(DC only) DPDT MY2N1-D2 MY2IN1-D2
4PDT MY4N1-D2 MY4IN1-D2
4PDT (bifurcated) MY4ZN1-D2 MY4ZIN1-D2
Example: MY2 6VAC (S)
Rated coil voltage
New model
2General-purpose Relay MY New model
Accessories (Order Separately)
Sockets
Socket Hold-down Clip Pairing
Mounting Plates for Sockets
Note: PYP-18 and PYP-36 can be cut into any desired length in accordance with the number of Sockets.
Track and Accessories
Specifications
Coil Ratings
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/20% for rated currents and
±15% for DC coil resistance.
2. Performance characteristic data are measured at a coil temperature of 23°C.
3. AC coil resistance and impedance are provided as reference values (at 60 Hz).
4. Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a bleeder
resistor if required.
5. Rated voltage denoted by * will be manufactured upon request. Ask your OMRON representative.
Poles Front Mounting
Socket (DIN-track/
screwless clamp
[SLC])
Front-mounting
Socket (DIN-track/
screw mounting)
Back-mounting Socket
Solder terminals Wire-wrap terminals PCB terminals
Without clip With clip Without clip With clip
2 PYF08S PYF08A-E
PYF08A-N PY08 PY08-Y1 PY08QN
PY08QN2 PY08QN-Y1
PY08QN2-Y1 PY08-02
4 PYF14S PYF14A-E
PYF14A-N
PYF14-ESS
PYF14-ESN
PY14 PY14-Y1 PY14QN
PY14QN2 PY14QN-Y1
PY14QN2-Y1 PY14-02
Relay type Poles Front Mounting Socket
(DIN-track/screwless clamp
[SLC])
Front-connecting Socket (DIN-track/
screw mounting) Back-connecting Socket
Solder/Wire-wrap terminals PCB terminals
Socket Clip Socket Clip Socket Clip
Without 2-pole
test button 2 PYF08S PYCM-08S PYF08A-E
PYF08A-N PYC-A1 PY08(QN) PYC-P
PYC-P2 PY08-02 PYC-P
PYC-P2
4 PYF14S PYCM-14S PYF14A-E
PYF14A-N PY14(QN) PY14-02
PYF14-ESS
PYF14-ESN PYC0 (metal)
PYC35 (plastic)
2-pole
test button 2 PYF08S PYCM-08S PYF08A-E
PYF08A-N PYC-E1 PY08(QN) PYC-P2 PY08-02 PYC-P2
Socket model For 1 Socket For 18 Sockets For 36 Sockets
PY08, PY08QN(2), PY14, PY14QN(2) PYP-1 PYP-18 PYP-36
Supporting Track (length = 500 mm) PFP-50N
Supporting Track (length = 1,000 mm) PFP-100N, PFP-100N2
End Plate PFP-M
Spacer PFP-S
Rated voltage Rated current Coil
resistance Coil inductance
(reference value) Must
operate
voltage
Must
release
voltage
Max.
voltage Power
consumption
(approx.)
50 Hz 60 Hz Arm. OFF Arm. ON % of rated voltage
AC 6 V* 214.1 mA 183 mA 12.2 0.04 H 0.08 H 80% max. 30% min. 110% 1.0 to 1.2 VA
(60 Hz)
12 V 106.5 mA 91 mA 46 0.17 H 0.33 H
24 V 53.8 mA 46 mA 180 0.69 H 1.30 H
48/50 V* 24.7/
25.7 mA 21.1/
22.0 mA 788 3.22 H 5.66 H
110/120 V 9.9/10.8 mA 8.4/9.2 mA 4,430 19.20 H 32.1 H 0.9 to 1.1 VA
(60 Hz)
220/240 V 4.8/5.3 mA 4.2/4.6 mA 18,790 83.50 H 136.4 H
DC 6 V* 151 mA 39.8 0.17 H 0.33 H 10% min. 0.9 W
12 V 75 mA 160 0.73 H 1.37 H
24 V 37.7 mA 636 3.20 H 5.72 H
48 V* 18.8 mA 2,560 10.60 H 21.0 H
100/110 V 9.0/9.9 mA 11,100 45.60 H 86.2 H
General-purpose Relay MY New model 3
Contact Ratings
Note: Dont exceed the carry current of a Socket in use. Please see page 10.
Characteristics
Note: The values given above are initial values.
Endurance Characteristics
Item 2-pole 4-pole 4-pole (bifurcated)
Resistive load
(cosφ = 1) Inductive load
(cosφ = 0.4, L/R = 7 ms) Resistive load
(cosφ = 1) Inductive load
(cosφ = 0.4, L/R = 7 ms) Resistive load
(cosφ = 1) Inductive load
(cosφ = 0.4, L/R = 7 ms)
Rated load 5A, 250 VAC
5A, 30 VDC 2A, 250 VAC
2 A, 30 VDC 3 A, 250 VAC
3 A, 30 VDC 0.8 A, 250 VAC
1.5 A, 30 VDC 3 A, 250 VAC
3 A, 30 VDC 0.8 A, 250 VAC
1.5 A, 30 VDC
Carry current 10 A (see note) 5 A (see note)
Max. switching
voltage 250 VAC
125 VDC 250 VAC
125 VDC
Max. switching
current 10 A 5 A
Max. switching
power 2,500 VA
300 W 1,250 VA
300 W 1,250 VA
150 W 500 VA
150 W 1,250 VA
150 W 500 VA
150 W
Failure rate
(reference value) 5 VDC, 1 mA 1 VDC, 1 mA 1 VDC, 100 µA
Item All Relays
Contact resistance 100 m max.
Operate time 20 ms max.
Release time 20 ms max.
Max. operating frequency Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance 1,000 M min. (at 500 VDC)
Dielectric strength 2,000 VAC, 50/60 Hz for 1.0 min (1,000 VAC between contacts of same polarity)
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
Shock resistance Destruction: 1,000 m/s2
Malfunction: 200 m/s2
Endurance See the following table.
Ambient temperature Operating: 55°C to 70°C (with no icing)
Ambient humidity Operating: 5% to 85%
Weight Approx. 35 g
Pole Mechanical life (at 18,000 operations/hr) Electrical life
(at 1,800 operations/hr under rated load)
2-pole AC:50,000,000 operations min.
DC:100,000,000 operations min. 500,000 operations min.
4-pole 200,000 operations min.
4-pole (bifurcated) 20,000,000 operations min. 100,000 operations min.
4General-purpose Relay MY New model
Approved Standards
VDE Recognitions (File No. 112467UG, IEC 255, VDE 0435)
UL508 Recognitions (File No. 41515)
CSA C22.2 No. 14 Listings (File No. LR31928)
IMQ (File No. EN013 to 016)
LR Recognitions (File No. 98/10014)
SEV Listings (File No. 99.5 50902.01)
No. of poles Coil ratings Contact ratings Operations
2 6, 12, 24, 48/50, 100/110
110/120, 200/220,
220/240 VAC
6, 12, 24, 48, 100/110,
125 VDC
10 A, 250 VAC (cosφ=1)
10 A, 30 VDC (L/R=0 ms) 10 x 103
4 5 A, 250 VAC (cosφ=1)
5 A, 30 VDC (L/R=0 ms) 100 x 103
MY4Z AC; 50 x 103
No. of poles Coil ratings Contact ratings Operations
2 6 to 240 VAC
6 to 125 VDC 10 A, 30 VDC (General purpose)
10 A, 250 VAC (General purpose) 6 x 103
4 5 A, 250 VAC (General purpose)
5 A, 30 VDC (General purpose)
No. of poles Coil ratings Contact ratings Operations
2 6 to 240 VAC
6 to 125 VDC 10 A, 30 VDC
10 A, 250 VAC 6 x 103
4 5 A, 250 VAC (Same polarity)
5 A, 30 VDC (Same polarity)
No. of poles Coil ratings Contact ratings Operations
2 6, 12, 24, 48/50, 100/110
110/120, 200/220,
220/240 VAC
6, 12, 24, 48, 100/110,
125 VDC
10 A, 30 VDC
10 A, 250 VAC 10 x 103
4 5 A, 250 VAC
5 A, 30 VDC 100 x 103
MY4Z AC; 50 x 103
No. of poles Coil ratings Contact ratings Operations
2 6 to 240 VAC
6 to 125 VDC 10 A, 250 VAC (Resistive)
2 A, 250 VAC (PF0.4)
10 A, 30 VDC (Resistive)
2 A, 30 VDC (L/R=7 ms)
50 x 103
4 5 A, 250 VAC (Resistive)
0.8 A, 250 VAC (PF0.4)
5 A, 30 VDC (Resistive)
1.5 A, 30 VDC (L/R=7 ms)
50 x 103
No. of poles Coil ratings Contact ratings Operations
2 6 to 240 VAC
6 to 125 VDC 10 A, 250 VAC
10 A, 30 VDC 10 x 103
4 5 A, 250 VAC
5 A, 30 VDC 100 x 103
MY4Z AC; 50 x 103
General-purpose Relay MY New model 5
Engineering Data
Maximum Switching Power
Endurance
MY2 MY4, MY4Z
Switching current (A)
AC resistive load
DC resistive load
AC resistive load
DC resistive load
Switching current (A)
Switching voltage (V) Switching voltage (V)
AC inductive load
(cosφ=0.4)
DC inductive load
(L/R=7 ms)
AC inductive load
(cosφ=0.4)
DC inductive load
(L/R=7 ms)
10000
5000
3000
1000
500
300
100
50
30
10
10000
5000
3000
1000
500
300
100
50
30
10
MY2 (Resistive Loads) MY2 (Inductive Loads)
Endurance (x10 operations)
3
Switching current (A)
250 VAC
30 VDC 30 VDC
250 VAC
Endurance (x10 operations)
3
Switchin
g
current
(
A
)
30 VDC
250 VAC
250 VAC
30 VDC
10000
5000
3000
1000
500
300
100
50
30
10
10000
5000
3000
1000
500
300
100
50
30
10
MY4 (Resistive Loads) MY4 (Inductive Loads)
Endurance (x10 operations)
3
Switching current (A)
250 VAC
30 VDC
30 VDC
250 VAC
Endurance (x10 operations)
3
Switchin
g
current
(
A
)
30 VDC
250 VAC
250 VAC
30 VDC
6General-purpose Relay MY New model
Technical and Environmental Properties
2-Pole model 4-Pole model
Tracking Resistance 600 CTI (base) 600 CTI (base)
Environmental Protection RT1 RT1
Flammability Class Base, Insulator, Spool ul 94V-0
Case, Indicator, Nameplate, Push Button ul 94V-2
Pollution Degree 21
Creepage Distance 4.0 mm 3.2 mm
Clearance Distance 3.0 mm 3.0 mm
Contact Material Ag AgNi + Au
10000
5000
3000
1000
500
300
100
50
30
10
10000
5000
3000
1000
500
300
100
50
30
10
MY4Z (Resistive Loads) MY4Z (Inductive Loads)
Endurance (x10 operations)
3
Switching Current (A)
250 VAC
30 VDC
250 VAC
30 VDC
250 VAC
250 VAC
30 VDC
30 VDC
Endurance (x10 operations)
3
Switching Current (A)
General-purpose Relay MY New model 7
Typical information for reference only
The following data is provided as experimental and/or calculated data for reference only. These figures fall under the category of typical behaviour
and the operation of individual relays will vary according to the exact operating conditions.
Typical Operate / Release Times 2-Pole model 4-Pole model
AC Type (operate / release time) 8 ms/8 ms 10 ms/10 ms
DC Type (operate / release time) 14 ms/4 ms 14 ms/6 ms
Load reduction Factor
For AC inductive loads (such as solenoids, contactors coils, etc.) the re-
duction factor corresponding to cos(p.f.) (cosine of the power factor) is
multiplied by the rated current in order to identify the maximum allowable
current. This approximation is not valid for loads with high inrush cur-
rents such as electric motors or fluorescent lamps.
Multiple Contact DC Switching Capacity Effect of temperature on coil voltages
Switching capacity of DC resistive load MY2/4 Operating range (DC and AC type) vs ambient temperature
This graph can be used to estimate the number of contacts that can be
used to switch DC resistive loads This graph shows the typical relationship between the maximum / mini-
mum coil and pick-up voltage and ambient temperature
Reduction factor
cos(p.f.)
1
0.8
0.6
0.4
1 0.8 0.6 0.4 0.2
0,1
1
10
100
20 40 60 80 100 120 140 160 180 200 220
Switching Voltage (Vdc)
Switching Current (A)
4 contacts
3 contacts
2 contacts
in series MY2
MY4
2
1
0 1020304050607080
Ambient temperature (˚C)
0.5
1.0
1.5
2
U/Un
1: Max coil voltage permitted.
2: Min pick-up voltage with coil
at ambient temperature
8General-purpose Relay MY New model
Dimensions
Note: All units are in millimeters unless otherwise indicated.
2-Pole Models
4-Pole Models
Models with Test Button
0.5
6.4
MY2N
21.5 max.
36 max.
28 max.
2.6
Eight, 1.2 dia. × 2.2 long holes
0.5
21.5 max.
36 max. 6.4
MY4N
28 max.
2.6
Eight, 1.2 dia. × 2.2 long holes
36 max.
MY2IN
8
14.2
5
80.5 6.3
2.6
Eight, 1.2 dia. × 2.2 long holes
21.5 max.
28 max.
MY4IN
36 max.
<1.417>
Fourteen, 1.2 dia. × 2.2 long holes
0.5
80.5 6.3
5
6.4
14.2
8
2.6
21.5 max.
28 max.
General-purpose Relay MY New model 9
Terminal Arrangement/Internal Connections (Bottom View)
Note: The DC models have polarity.
1
5
9
13
4
8
12
14
1
5
9
13
4
8
12
14
1
5
9
13
4
8
12
14
1
5
9
13
4
8
12
14
1
5
9
13
4
8
12
14
1
5
9
13
4
8
12
14
1
5
9
13
4
8
12
14
1
5
9
13
4
8
12
14
2
6
10
3
7
11
1
5
9
4
8
12
2
6
10
3
7
11
1
5
4
8
2
6
3
7
1
5
4
8
2
6
3
7
1
5
9
4
8
12
2
6
10
3
7
11
1
5
4
8
2
6
3
7
1
5
4
8
2
6
3
7
13 14 13 14 13 14
13 14 13 14 13 14
MY2 MY2N/MY2IN
(AC Models) MY2N/MY2IN
(DC Models) MY2N-D2/MY2IN-D2
(DC Models Only)
MY2N-CR/MY2IN-CR
(AC Models Only) MY2N1/MY2IN1
(DC Models Only) MY2N1-D2/MY2IN1-D2
(DC Models Only)
MY4(Z) MY4(Z)N/MY4(Z)IN
(AC Models) MY4(Z)N/MY4(Z)IN
(DC Models) MY4(Z)N-D/MY4(Z)IN-D2
(DC Models Only)
MY4(Z)N-CR/MY4(Z)IN-CR
(AC Models Only) MY4(Z)N1/MY4(Z)IN1
(DC Models Only) MY4(Z)N1-D2/MY4(Z)IN1-D2
(DC Models Only)
+− +−
−+ −+
+− +−
−+ −+
10 General-purpose Relay MY New model
Socket for MY
Track-mounted (DIN Track) Socket
Conforms to VDE 0106, Part 100
Snap into position along continuous sections of any mount-
ing track.
Facilitates sheet metal design by standardized mounting di-
mensions.
Design with sufficient dielectric separation between termi-
nals eliminates the need of any insulating sheet.
Safety Standards for Sockets
Back-connecting Sockets
Specifications
Note: 1. The values given above are initial values.
2. The values for insulation resistance were measured at 500 V at the same place as the dielectric strength.
3. The maximum operating ambient temperature for the PYF08A-N and PYF14A-N is 55°C.
4. When using the PYF08A-N or PYF14A-N at an operating ambient temperature exceeding 40°C, reduce the current to 60%.
5. The MY2(S) can be used at 70°C with a carry current of 7 A.
Model Standards File No.
PYF08A-E, PYF08A-N
PYF14A-E, PYF14A-N UL508 E87929
CSA22.2 LR31928
PYF14-ESN,
PYF14-ESS UL508 E244189
CSA22.2 LR225761
Item Pole Model Carry current Dielectric withstand
voltage Insulation resistance
(see note 2)
Screwless Clamp
Terminal Socket 2 PYF08S 10 A 2,000 VAC, 1 min Less than 1,000 M
4 PYF14S 5 A
Track-mounted
Socket 2 PYF08A-E 7 A 2,000 VAC, 1 min 1,000 M min.
PYF08A-N (see note 3) 7 A (see note 4)
4 PYF14A-E 5 A
PYF14A-N (see note 3) 5 A (see note 4)
4 PYF14-ESN/-ESS 12 A > 3 kV > 5 M
Back-connecting
Socket 2 PY08(-Y1) 7 A 1,500 VAC, 1 min 100 M min.
PY08QN(-Y1)
PY08-02
4 PY14(-Y1) 3 A
PY14QN(-Y1)
PY14-02
General-purpose Relay MY New model 11
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Socket Dimensions Terminal arrangement/
Internal connections
(top view)
Mounting holes
---
PYF08S
(5.3)
85 max.
38.2 max.
36.5 max.
23.2 max.
PYF08A-E
31 max.
23 max.
72 max.
Two, 4.2 x 5
mounting
holes
Eight, M3 x 8
sems screws
(TOP VIEW)
Two, M3, M4, or 4.5-dia. holes
Note: Track mounting is also
possible. Refer to page
12 for supporting tracks.
PYF08A-N
4
42
8
44
1
12
5
14
41
12
A2
14
11
9
A1
13
A2
14
PYF-08A-N 73
22 max.
67 max.
30 max.
4
42
1
85
12 9
14 14 13
44
12
14
41 11
A2 A2 A1
18.7
3.0 dia.
3.5 dia. or M3
Note: Track mounting is also
possible. Refer to page
12 for supporting tracks.
12 General-purpose Relay MY New model
---
Socket Dimensions Terminal arrangement/
Internal connections
(top view)
Mounting holes
PYF14S 36.5 max.
31 max.
85 max.
PYF14A-E
31 max.
29.5 max.
72 max.
Two, 4.2 x 5
mounting
holes Fourteen, M3 x 8
sems screws
(TOP VIEW)
Two, M3, M4, or 4.5-dia. holes
Note: Track mounting is also
possible. Refer to page
12 for supportin
g
tracks.
PYF14A-N 4
42
3
32
2
22
1
12
8
44
7
34
6
24
5
14
41
12
31
11
21
10
11
9
A1
13
A2
14
A2
14
PYF-14A-N
73
30 max.
67 max.
29.5 max.
4 3 2 1
8 7 6 5
12 11 10 9
14 14 13
42 32 22 12
44 34 24 14
41 31 21 11
A2 A2 A1
26
Two, 4.5 dia. or M4
Note: Track mounting is also
possible. Refer to page
12 for supporting tracks.
General-purpose Relay MY New model 13
Socket Dimensions Terminal arrangement/
internal connections (top view)/
mounting holes
PYF14-ESN
PYF14-ESS
27 42.5
27
Relay
Module
80
53
24
22.5
9
3.2
82
Label
75
4.45 4.45 4.45
4.1
6.3
6.4
NO
NC
COIL
COM.
27
61
82
55
29
22.5
9
3.2
83 75
4.45 4.45 4.45
4.1
6.3
6.4
COM.
NC
NO
COIL
14 General-purpose Relay MY New model
Note: Use a panel with plate thickness of 1 to 2 mm for mounting the Sockets.
Socket Dimensions Terminal arrangement/
Internal connections
(bottom view)
Mounting holes
PY08/PY08-Y1
(See note) Eight, 3 x 1.2 elliptical holes
25.5 max.
29.5 max.
24 max.
42 max.
Note: The PY08-Y1 includes sections indicated by
dotted lines.
20 max.
PY08QN/
PY08QN-Y1
(See note) 29.5 max.
22 max.
24 max.
41.5 max.
42 max.
Note: The PY08QN-Y1 includes sections
indicated b
y
dotted lines.
PY08-02
16.5 max.
22 max.
25.5 max.
29.5 max.
Eight, 1.3-dia.
holes
PY14/PY14-Y1
(See note) Fourteen, 3 x 1.2 elliptical holes
25.5 max.
29.5 max.
24 max.
42 max.
Note: The PY14-Y1 includes sections indicated by
dotted lines.
20 max.
PY14QN/
PY14QN-Y1
(See note)
29.5 max.
22 max.
24 max.
41.5 max.
42 max.
Note: The PY14QN-Y1 includes sections
indicated b
y
dotted lines.
PY14-02
16.5 max.
22 max.
25.5 max.
29.5 max.
Fourteen, 1.3-dia.
holes
General-purpose Relay MY New model 15
Hold-down Clips
Mounting Plates for Back-connecting Sockets
Tracks and Accessories
Supporting Tracks
PFP-50N/PFP-100N
4.5
1.2
36.3
4.5
36.3
5.75 4.25
4.5±0.1
5
3.3
38.5
10
28
PYC-P PYC-P2
29 max.
PYC-A1
(2 pcs per set) PYC-E1
(2 pcs per set)
For sockets PYF14-ESN/-ESS
Note: For total dimensions with plastic
clip please refer to drawings of
the sockets.
Model Description
PYC 0 Metal spring clip (Used with
Relay only)
PYC 35 Plastic holding clip (Used with
Relay only)
PYC TR1 Thermoplastic writeable label
PYP-1 PYP-36
PYP-18
t=1.6
Two, 3.4-dia. holes
72 elliptical holes
72 elliptical holes
4.5
15 25 25
10 25
1000 (500) *
25
10 15 (5) 1
35±0.3
7.3±0.15
27±0.15
Note: The figure in the parentheses is for PFP-50N.
16
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.Cat. No. J03E-EN-01A
OMRON EUROPE B.V.
Wegalaan 67-69,
NL-2132 JD, Hoofddorp,
The Netherlands
Phone: +31 23 568 13 00
Fax: +31 23 568 13 88
www.eu.omron.com
PFP-100N2
End Plate
PFP-M
Spacer
PFP-S
Precautions
Refer to General Precautions on page 11 of the General-purpose Relays and Power Relays Group Catalog (X034).
Connections
Do not reverse polarity when connecting DC-operated Relays with
built-in diodes or indicators or high-sensitivity DC-operated Relays.
Mounting
Whenever possible, mount Relays so that it is not subject to vibra-
tion or shock in the same direction as that of contact movement.
29.2
1.5
27 24
16
1
4.5
15 25 25
10 25
1000 25
10 15
35±0.3
50
11.5
10
10
6.2
1.8
1
35.5 35.3
1.8
1.3
4.8
M4 x 8 pan head screw
M4 spring washer
5
16
12
44.3
16.5
34.8