INTEGRATED CIRCUITS DIVISION
www.ixysic.com
2R02
CPC1976YX6
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to the
device. Functional operation of the device at conditions beyond
those indicated in the operational sections of this data sheet is
not implied.
Absolute Maximum Ratings @ 25ºC
Parameter Ratings Units
Blocking Voltage (VDRM) 600 VP
Reverse Input Voltage 5 V
Input Control Current 50 mA
Peak (10ms) 1 A
di/dt Critical Rate of Rise
of On-State Current 40 A/s
Input Power Dissipation 1150 mW
Total Power Dissipation 22400 mW
ESD, Human Body Model 4 kV
i2t for Fusing (1/2 Sine Wave, 60Hz) 3.5 A2s
Isolation Voltage, Input to Output 3750 Vrms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 20 mW / ºC
Electrical Characteristics @ 25ºC
Parameters Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current, Continuous VL=20-240Vrms IL0.070 - 2 Arms
Maximum Surge Current t < 16ms IPK --20 A
Off State Leakage Current VDRM I
LEAK --10 A
On-State Voltage Drop IL=2AP- - 1.1 1.25 VP
Critical Rate of Rise - dv/dt 1000 1200 - V/s
Switching Speeds
Turn-on IF = 5 mA, Resistive
VL=20V, 60Hz
ton - 20 500 s
Turn-off toff - - 0.5 cycle
Holding Current - IH- - 75 mA
Latching Current - IL- - 100 mA
Operating Frequency - 20 - 500 Hz
Input Characteristics
Input Control Current to Activate 160Hz IF--5 mA
Input Drop-out Voltage - - 0.8 - - V
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR--10 A
Common Characteristics
Input to Output Capacitance - CI/O --3 pF
1 For high-noise environments, or for high-frequency operation, use IF > 10mA.