Bel Power Solutions MAP80 Series of power supplies provides reliable, tightly-regulated DC power for commercial and industrial systems which require high peak current capabilities. Wide-range AC input and full international safety, EMI, and ESD compliance ensure worldwide acceptance. All units bear the CE Mark. The MAP80 utilizes a variable frequency design with a thermally efficient U-channel chassis to provide full power operation in convection-cooled applications. Design innovations include metric and SAE mounting inserts on each mounting surface to provide integration flexibility. Dual-mode connectors provide traditional terminal block connections or popular single-row Molex connector mating. Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements. * RoHS Compliant * Wide Range Input for 110/220 VAC Applications * CE marked to Low Voltage Directive * Input Transient and ESD Compliance to EN61000-4-2/-3/-4 * Meets EN55022, Class B Limits * TTL Compatible Power Fail Signal * Greater than 175,000 Hours MTBF * Metric and SAE Mounting Inserts MAP80 Series 2 MODEL7 OUTPUT VOLTAGE ADJUSTMENT RANGE MAX OUTPUT CURRENT PEAK OUTPUT CURRENT1 LINE REGULATION MAP80-1012G6 12V/15V 11.5V to 15.5V 7.5/6.0A3 9.2/7.3A 0.2% MAP80-1024G6 24V/28V 23.0V to 29.0V 3.8/3.2A 4.6/3.9A 0.1% MODEL7 OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT PEAK OUTPUT CURRENT4 LINE REGULATION MAP80-4000G5 MAP80-4001G5 MAP80-4002G5 MAP80-4003G5 MAP80-4004G5 MAP80-4010G5 RIPPLE & NOISE2 INITIAL SETTING ACCURACY 1% 1% 11.76V to 12.15V 0.5% 0.5% 23.8V to 24.2V LOAD REGULATION RIPPLE & NOISE2 INITIAL SETTING ACCURACY LOAD REGULATION +5V 4.8V to 5.5V 14A 16A 0.2% 1% 1% 5.1V to 5.2V +12V 11.52V to 12.48V 4A 7A 0.2% 1% 1% 11.9V to 12.1V -5V Fixed 1A 1A 0.5% 2% 1% -4.8V to -5.4V -12V Fixed 1A 1A 0.5% 2% 1% -11.5V to -12.5V +5V 4.8V to 5.5V 14A 16A 0.2% 1% 1% 5.1V to 5.2V +24V 23.04V to 24.96V 2A 3.5A 0.2% 1% 1% 24.0V to 24.1V -12V Fixed 1A 1A 0.5% 2% 1% -11.5V to -12.5V +12V Fixed 1A 1A 0.5% 2% 1% 11.5V to 12.5V +5V 4.7V to 5.5V 14A 16A 0.2% 1% 1% 5.1V to 5.2V +12V 11.52V to 12.48V 4A 7A 0.2% 1% 1% 12.0V to 12.1V -12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V +12V Fixed 1A 1A 0.5% 2% 1% 11.6V to 12.4V +5V 4.8V to 5.5V 14A 16A 0.2% 1% 1% 5.1V to 5.2V +15V 14.4V to 15.6V 3.5A 6A 0.2% 1% 1% 14.6V to 15.1V -5V Fixed 1A 1A 0.5% 2% 1% -4.8V to -5.4V -15V Fixed 1A 1A 0.5% 2% 1% -14.4V to -15.5V +5V 4.8V to 5.5V 14A 16A 0.2% 1% 1% 5.1V to 5.2V +24V 23.04V to 24.96V 2A 3.5A 0.2% 1% 1% 24.0V to 24.1V -15V Fixed 1A 1A 0.5% 2% 1% -14.4V to -15.5V +15V Fixed 1A 1A 0.5% 2% 1% 14.4V to 15.5V +5V 4.8V to 5.5V 14A 16A 0.2% 1% 1% 5.1V to 5.2V +12V 11.52V to 12.48V 4A 7A 0.2% 1% 1% 12.0V to 12.1V -5V Fixed 1A 1A 0.5% 2% 1% -4.8V to -5.4V -12V Fixed 3A 3A 0.5% 2% 1% -11.5V to -12.5V 1 Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum. Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 3 MAP80-1012 output currents are expressed as 12V/15V operation. MAP80-1024 output currents are expressed as 24V/28V operation. 4 Peak loads up to 90 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 90 Watts. 5 Output rated 65 W max for 50C ambient, convection cooled. 6 Output rated 75 W max for 50C ambient, convection cooled. 7 Non-G models use lead solder exemption and are not recommended for new designs. 2 tech.support@psbel.com MAP80 Series PARAMETER 3 CONDITIONS / DESCRIPTION MIN MAX UNITS Input Voltage - AC Continuous input range 90 175 135 264 VAC Input Frequency AC input 47 63 Hz Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 90 VAC Hold-up Time Nominal AC input voltage (115VAC), full rated load. 20 ms Input Current 90 VAC (80 W load) 110VAC (80W load) Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor, Vin = 264 VAC (one cycle), 25 C Operating Frequency Switching frequency of power supply (varies with load) PARAMETER CONDITIONS / DESCRIPTION Efficiency Minimum Loads NOM 22 MIN Full load @ 115 VAC. Varies with distribution of loads among outputs. MAP80-1012 MAP80-1024 All multiple output models, main channel only NOM 2.5 1.8 ARMS 45 APK 120 kHz MAX UNITS 73% typical 0.42 0.21 1.50 Amps Ripple and Noise Full load, 20 MHz bandwidth. Output Power Continuous output power, all multiple output models. Peak output power (60s maximum, 10% duty cycle), all multiple output models. 80 90 Watts Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on, V1, V2. 1 % Regulation Transient Response See Model Selection Chart Varies by output. Total regulation includes: line changes from 90-132 VAC or 175-264, changes in load starting at 20% load and changing to 100% load. Recovery time, to within 1% of initial set point due to a 50-100% load change, 4% max. deviation. (Main output of multiple output units). See Model Selection Chart Turn-on Delay Time required for initial output voltage stabilization. Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. PARAMETER CONDITIONS/DESCRIPTION MIN Provided on the main output of multiple output units. MAP80-1012 MAP80-1024 Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. 5.5 17.5 32 Overvoltage Protection Overload Protection 1 NOM Logic LO (denotes power fail detected). 500 s 5 Sec 20 ms MAX UNITS 6.8 23 37 V 0.7 Logic HI with internal pull-up to output. V k 5.1 Power Fail Warning 8 8 Power Fail trip point, maximum load, decreasing line. 86 Time before regulation dropout, at full load, due to loss of input power. 4 94 VAC ms Power Fail Warning is not available for MAP80-1024. The MAP80-1012 is an open collector output, capable of sinking 35 mA, maximum Europe, Middle East +353 61 225 977 North America +1 408 785 5200 (c) 2018 Bel Power Solutions & Protection BCD.00565_AE Asia-Pacific +86 755 298 85888 MAP80 Series 4 PARAMETER Agency Approvals Dielectric Withstand Voltage Electromagnetic Interference, Conducted Input Transient Protection CONDITIONS / DESCRIPTION Insulation Resistance Input to output Leakage Current Per EN60950, 264 VAC PARAMETER CONDITIONS / DESCRIPTION Altitude Operating Temperature9 MIN Approved to the latest edition of the following standards; UL/CSA60950-1 2nd, IEC60950-1 2nd and EN60950-1 2nd. Input to Chassis Input to Output (tested by manufacturer only) FCC CFR title 47 Part 15 Sub-Part B - conducted & radiated. EN55022 / CISPR 22 conducted. EN55022 / CISPR 22 radiated. Line to Line EN61000-4-5 Level 3 Line to Ground Operating Non-operating Derate linearly above 50C by 2.5% per C to a maximum temperature of 70C NOM MAX 2121 4242 B B B 1 VDC Class kV 2 M 7 MIN At 100% load: At 50% load: Storage Temperature UNITS NOM 500 A MAX UNITS 0 0 10k 40k 50 70 -40 85 C 0.03 %/C 95 %RH C Temperature Coefficient 0C to 70C (after 15 minute warm-up) Relative Humidity Non-condensing Shock Operating, peak acceleration 20 G Vibration Random vibration, 10Hz to 2kHz, 3 axis 6 GRMS 9 0.02 ASL Feet 5 The use of an external cooling fan (100LFM (linear feet per minute), minimum) shall be determined at end use if the 25C ambient is exceeded. PARAMETER CONDITIONS / DESCRIPTION Dimensions Weight Cover (Option) MIN NOM MAX UNITS 182.9 x 106.7 x 45.7 7.2 x 4.2 x 1.8 0.82 1.8 mm in kg lb 182.9 x 106.7 x 50.0 7.20 x 4.20 x 1.97 mm in Add `C' suffix to model number or order part number 412-59585-G separately. For convection cooled applications, derate output power to 65 watts on all multiple output models and MAP80-1005. Derate MAP801012 and MAP80-1024 to 75 watts. Dimensions: tech.support@psbel.com MAP80 Series CONNECTOR Input & Output Connectors 5 CONDITIONS / DESCRIPTION 6-32 screw wire clamps on 0.312" (7.9 mm) centers, 0.045" (1.1 mm) square pins on 0.156" (3.9 mm) centers, mates with Molex series 2139, 6442, or 41695 Matting Connectors J1: 0.035" (0.9 mm) square pins on 0.100" (2.5 mm) centers, mates with Molex series 2695/6471 Chassis 0.090" (2.3 mm) aluminum alloy, with clear finish Figure 1. Mechanical Drawing NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. Europe, Middle East +353 61 225 977 North America +1 408 785 5200 (c) 2018 Bel Power Solutions & Protection BCD.00565_AE Asia-Pacific +86 755 298 85888