SPECIFICATION
MODEL LPV-20-5 LPV-20-12 LPV-20-15 LPV-20-24
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT
LINEREGULATION
LOADREGULATION
SETUP,RISETIME Note.6
HOLDUP TIME(Typ.)
VOLTAGERANGE Note.4
FREQUENCY RANGE
EFFICIENCY (Typ.)
ACCURRENT (Typ.)
INPUT
INRUSHCURRENT(max.)
LEAKAGECURRENT
SAFETY STANDARDS
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
5V 12V 15V 24V
3A 1.67A 1.33A 0.84A
0~3A 0~1.67A 0~1.33A 0~0.84A
15W 20W 20W 20.2W
80mVp-p 120mVp-p 120mVp-p 150mVp-p
¡Ó
5.0%
¡Ó
1.0%
¡Ó
2.0%
500ms,20ms/230VAC5 atfullload00ms,20ms/115VAC
90~264VAC 127~370VDC
47~63Hz
77% 81% 83% 83%
5.75~6.75V 13.8~16V 17.5~21V 28~32V
0.55A/115VAC0.35A/230VAC
0.25mA /240VAC
110~150%ratedoutputpower
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
CompliancetoEN55022(CISPR22)ClassB, EN61000-3-2Class A,EN61000-3-3
CompliancetoEN61000-4-2,3,4,5,6,8,11,EN55024,lightindustrylevel,criteria A
-30~+70
¢J
(Referto"DeratingCurve")
20~90%RH non-condensing
-40~+80 ,10~95%RH
¢J
¡Ó ¢J ¢J
0.03%/ (0~50 )
10~500Hz,2G10min./1cycle,periodfor 60min.eachalongX, Y,Zaxes
UL879,UL1310,CSA C22.2No.207-M89,CAN/CSA C22.2No.223-M91,IP67approved;designreferto TUVEN60950-1
786.5Khrsmin.MIL-HDBK-217F(25 )
¢J
118*35*26mm(L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute.
¢J
0.22Kg;60pcs/14.2Kg/0.62CUFT
Protectiontype: Shutoffo/pvoltage,clampingbyzenerdiode
20WSingleOutputSwitchingPowerSupply
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
Constant voltage design
Universal AC input / Full range
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
Fully encapsulated with IP67 level
Class 2 power unit
ass LPS
Suitable for LED lighting and moving sign applications
100% full load burn-in test
Low cost, high reliability
2 years warranty
¡E
¢º
Small and compact size
(Note.7)
Fully isolated plastic case
Class power unit, no FG
P
¡½
Features :
LPV-20 serie s
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
50ms/230VAC16ms/115VACatfullload
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVAC
I/P-O/P:>100MOhms/500VDC/25 /70%RH
¢J
FileName:LPV-20-SPEC 2012-12-26
IP67
LPS
EMCIMMUNITY
EMCEMISSION
COLDSTART 70A(t =215smeasuredat50%I )at230VAC
width peak
£g