100W Single Output with Battery Charger(UPS Function) PSC-100 series .. SPECIFICATION MODEL OUTPUT PSC-100A CH1 CH2 CH1 CH2 DC VOLTAGE 13.8V 13.8V 27.6V 27.6V RATED CURRENT 4.75A 2.5A 2.4A 1.25A CURRENT RANGE 0 ~ 7A -------- 0 ~ 3.5A -------- RATED POWER 100.05W CH1: 12 ~ 15V VOLTAGE TOLERANCE Note.3 1.0% -------- 0.5% -------- LOAD REGULATION 0.5% -------- 0.5% -------- Note.4 2400ms, 30ms/230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE 40ms/230VAC 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz 2400ms, 30ms/115VAC at full load 16ms/115VAC at full load 127 ~ 370VDC 88% EFFICIENCY (Typ.) 86% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2A/115VAC 1.2A/230VAC COLD START 35A/115VAC 70A/230VAC LEAKAGE CURRENT <1mA / 240VAC OVERLOAD 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1:14.49 ~ 18.63V CH1:28.98 ~ 37.26V Protection type : Shut down o/p voltage, re-power on to recover AC OK BATTERY LOW VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF DIMENSION PACKING 201V 100.5V Note.6 Relay contact output, ON : AC OK ; OFF : AC Fail ; Max. rating : 30V / 1A WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT NOTE -------- -------- 0.5% WORKING TEMP. OTHERS -------- LINE REGULATION BATTERY CUT OFF (Note 4) 100mVp-p CH1: 24 ~ 29V 1.0% OVER VOLTAGE EMC -------- VOLTAGE ADJ. RANGE PROTECTION ALARM FUNCTION 100.74W RIPPLE & NOISE (max.) Note.2 100mVp-p SETUP, RISE TIME INPUT PSC-100B OUTPUT NUMBER Relay contact output, OFF : Battery OK ; ON : Battery Low ; Max. rating : 30V / 1A Battery low voltage : < 11V -20 ~ +70 (Refer to "Derating Curve") Battery low voltage : < 22V 20 ~ 90% RH non-condensing -20 ~ +85, 10 ~ 95% RH 0.03%/ (0~50) on CH1 output 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A 417.6K hrs min. MIL-HDBK-217F (25) PCB:127*76.2*31mm (L*W*H) ; Enclosed type:130*85*37mm (L*W*H) PCB:0.23Kg; 63pcs/15.5Kg/1.35CUFT ; Enclosed type:0.44Kg;32pcs/15Kg/0.64CUFT File Name:PSC-100-SPEC 2014-07-03 PSC-100 100W Single Output with Battery Charger(UPS Function) Mechanical Specification series Unit:mm 5.7 Cover: No. 946B-T CN2 64.75 1 2 3 4 5 6 7 8 1 2 3 CN3 4 FS1 3 2 1 CN1 SVR1 HS2 HS3 4 - 115.8 5.6 3.8 Mylar film 18 31max. 127 7.1 2-M3 L=4 115.8 2-M3 37 3max. 76.2 AC FUSE T3.15A/250V 6 -M 3 L=4 8.2 78 AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. 1 2 3 Assignment AC/N No Pin AC/L Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Assignment -V +V Bat+ Bat- 62 6 17 7 85 26 Alarm Output Connector(CN3) : JST B4B-XH or equivalent DC Output Connector (CN2) : JST B8P-VH or equivalent Pin No. 1,2 3,4 5,6 7,8 130 L-Bracket: No. 946A-D 41. 8.6 Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Pin No. Assignment 1 2 Mating Housing Terminal JST XHP or equivalent JST SXH-001T-P0.6 or equivalent AC OK 3 4 Bat. Low Block Diagram RL1 AC OK RL2 Bat. Low ALARM CIRCUIT I/P EMI FILTER & RECTIFIER POWER SWITCHING FG O.L.P. PWM CONTROL RECTIFIERS & FILTER +V -V Bat. + DETECTION CIRCUIT O.V.P. Bat. Battery Charger & Back up Control File Name:PSC-100-SPEC 2014-07-03 100W Single Output with Battery Charger(UPS Function) Output Derating PSC-100 series Output Derating VS Input Voltage 100 100 PCB only 90 80 70 LOAD (%) LOAD (%) 60 50 40 20 -20 PCB only Enclosed type 80 Enclosed tpye 0 10 20 30 40 50 60 60 50 40 70 (HORIZONTAL) 90 95 100 115 AMBIENT TEMPERATURE () 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz Suggested Application 1.Backup connection for AC interruption (1) Please refer to the Fig1.1 for suggested connection. The power supply charges the battery and provides energy to the load at the same time when the AC main is OK. The battery starts to supply power to the load when the AC mains fails. -V +V + Load Bat+ Bat- + - A : 12V B : 24V Battery Fig 1.1 Suggested system connection 2.Alarm signal for AC OK and Battery Low (1) Alarm signal is sent out through " AC OK " & " Battery Low " pins.(relay contact type) (2) An external voltage source is required for this function. The maximum applied voltage is 30V and the maximum sink current is 1A. (3) Table2.1 explains the alarm function built in the power supply Function AC OK Battery Low Output of Alarm Description AC OK (Battery low) CN3 Pin1(Pin3) The signal is "Low" when the power supply turns on Low or short The signal turns to be "High" when the power supply turns OFF High or open(External applied voltage 30V max.) The signal is "Low" when the voltage of battery is under A:11V, B:22V Low or short The signal is "High" when the voltage of battery is above A:11V, B:22V High or open(External applied voltage 30V max.) R V CN3 Pin2(Pin4) Table 2.1 Explanation of Alarm Signal (4) RL1 (AC OK)signal will go into hiccup mode when the overload protection is activating. External voltage source (V) and resistor (R) (The max. Sink is 1A and 30V) Fig 2.2 Internal circuit of AC OK (Battery Low) File Name:PSC-100-SPEC 2014-07-03 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Mean Well: PSC-100B PSC-100A PSC-100A-C