30
13
30
10
Applicable fluid:
Air, Non-corrosive gas, Non-flammable gas
PS1000-R06L
MADE IN JAPAN
G
AIRCHECKER
RoHS
PS1000/PS1100/PS1200 Series
Air Checker: Electronic Pressure Switch
(For Positive Pressure)
(For Vacuum,
Residual Pressure)
(For Vacuum)
Compact/lightweight
electronic pressure switch
Addition of vacuum range (−100 to 0 kPa)
Easy adjustment of pressure setting trimmer
[Option]
Positive pressure
adjustment range
100 kPa
PS1200 (For vacuum)
0 kPa 0.1 MPa
0 MPa
PS1000/1100
0.45 MPa/0.4 MPa
220°
Vacuum
adjustment
range
Easy mounting
Plug-in reducer port for One-touch fittings
High visibility
A large LED display for an easily
visible switch
2-wire type
Applicable to either NPN or PNP output
105
ZSE30
ISE30
ZSE20
ISE20
ZSE40
ISE40
ZSE10
ISE10
ISE70
ZSE80
ISE80
PS
ISA2
ISE35
ISA3
PSE
IS
ISG
ZSM1
PS
How to Order
RoHS
[Option]
QR06 LPS 0010
Output specifications
10
11
12
For positive pressure
For vacuum and residual pressure
For vacuum
Piping specifications
R06
R07
ø6 reducer
1/4" reducer
L3 m
Lead wire length
The PS1200 series is CE-
compliant (with Q) only.
Option (CE-compliant)
Nil
Q
None
CE-compliant
Switch output
Max. operating pressure
Set pressure range
Fluid
Indicator light
Temperature characteristics
Repeatability
Hysteresis
Load voltage
Load current
Leakage current
Internal voltage drop
Operating temperature range
Insulation resistance
Withstand voltage
Weight
Port size
Enclosure
Lead wire
Wetted parts material
Standards
Model PS1200
500 kPa
–100 to 0 kPa
10% F.S. or less
PS1000
Present pres. Setting pres.: ON
–0.1 to 0.45 MPa
PS1100
–0.1 to 0.4 MPa
Air/Non-corrossive gas/Non-flammable gas
ON: When red LED turns on
±3% F.S.
±1% F.S.
12 to 24 VDC ±10%, Ripple (p-p) 10% or less
5 to 40 mA
1 mA or less
5 V or less
0 to 60°C (No condensation)
2 M or more (500 VDC measured via megohmmeter) between terminals and housing
1000 VAC (in 50/60 Hz) for 1 minute between terminals and housing
5 g (Excluding lead wire)
R06: ø6 reducer, R07: 1/4" reducer
IP40
Pressured sensor part: Silicon, Body part: PBT, O-ring: HNBR
CE (Option), RoHS
Specifications
1 MPa
4% F.S. or less
Grommet oilproof heavy-duty vinyl cable 2 cores, ø2.55, 3 m,
Conductor area: 0.18 mm2, Insulator O.D.: 0.96 mm
Present pres. Setting pres.: ON
Refer to pages 11 and 12 for Pressure Switch Precautions. For details about the Specific Product
Precautions, refer to the Operation Manual on the SMC website, http://www.smcworld.com
Air Checker:
Electronic Pressure Switch
PS1000/1100/1200
Series
106
-
+
Use the pressure setting trimmer to
set ON pressure.
Rotate clockwise to increase the set
pressure. For setting vacuum, rotate
counterclockwise.
To set, use a flat head screwdriver
suited for the groove of the trimmer,
and rotate it lightly with finger tip.
Rotation angle of the trimmer is 220°.
There is a stop provided to prevent the trimmer from rotating beyond its
limits. Rotation beyond the limit can damage the trimmer. Adjust the
trimmer gently within the rotation angle.
+
High
pressure
High
vacuum
Pressure setting
trimmer
220°
Left end adjustment limit Right end adjustment limit
Setting of Pressure Switch Trimmer
30
25.5
13
3000
Pressure setting trimmer
LED indicator
PS1000-R06L
MADE IN JAPAN
G
AIRCHECKER
30
A
10
ø6 reducer
1/4" reducer
Internal Circuits and Wiring Examples Dimensions
KQ2H/L/T/S/Y06-M5
KQ2H/L07-M5
Other KQ2/KS series
KJ series
Dimensions
A
16
16
13
16
Applicable One-touch fittings
Switch Specifications
PS1000, PS1100 PS1200
Set pressure
t
MPa
PS1000 ON
OFF
PS1100 ON
OFF
0.4
0.2
0
–0.1
The switch turns ON
when the set pressure
is reached or exceeded.
The switch turns
ON when at the set
pressure or below.
Set pressure
t
kPa
PS1200 ON
OFF
0
–50
–100
The switch turns
ON when at the
set pressure or
below.
+
12 to 24
VDC
Brown OUT (+)
Blue OUT (−)
Main circuit
of switch
U
Load
+
12 to 24
VDC
Brown OUT (+)
Blue OUT (−)
Main circuit
of switch
U
Load
Switch
Input
COM
NPN
Source type
input unit
Brown
Blue
Switch
Input
COM
PNP
Sink type
input unit
Blue
Brown
For source type input unit
For sink type input unit
Example of connection with a PLC (Sequence controller)
PS1000/1100/1200 Series
Air Checker
Electronic Pressure Switch
107
ZSE30
ISE30
ZSE20
ISE20
ZSE40
ISE40
ZSE10
ISE10
ISE70
ZSE80
ISE80
PS
ISA2
ISE35
ISA3
PSE
IS
ISG
ZSM1
PS