WICKMANN USA, INC.• 4100 Shirley Dr. • Atlanta, GA 30336 • Tel: (404) 699-7820 • Fax: (404) 699-9176
• FaxBack: (800) 251-5490 • W• FaxBack: (800) 251-5490 • W
• FaxBack: (800) 251-5490 • W• FaxBack: (800) 251-5490 • W
• FaxBack: (800) 251-5490 • Web: http://wwweb: http://www
eb: http://wwweb: http://www
eb: http://www.wickmannusa.com.wickmannusa.com
.wickmannusa.com.wickmannusa.com
.wickmannusa.com
WICKMANN
000204
MINIATURE FUSE-LINKS
Rated Current 150% 210% 275% 400% 1000%
32 ... 100mA > 1h < 2min 200ms ... 10s 40ms ... 3s 10 ... 300ms
125mA ... 6.30A > 1h < 2min 600ms ... 10s 150ms ... 3s 20 ... 300ms
8.00 ... 16.00A > 30min < 10min - - 20 ... 300ms
Permissible continuous operating current is ≤≤
≤≤
≤ 100% at ambient temperature of 23ºC (73.4ºF).
IEC 60127-2/SS 3
• FaxBack Document # 202
• Glass tube
Brass caps, nickel-plated
• Approvals:
VDE: File No. 43285
SEMKO: File No. 8734099
BSI: File No. KM7850
IMQ: File No. E3267
cULus Recognized: File No. E 67006
CCEE: File No. CH0026528-98
MITI: 1.00A-5.00A: contact WICKMANN
• Packaging:
00: Bulk (1000 pcs. per Box)
02: Pack (10 pcs. per Pack)
40: Axial Leads/Bulk
43: Axial Leads/Tape & Reel
(1000 pcs. per Reel)
• Limits for Pre-ar cing Time
Series 195
5x20
mm
Time-Lag
1 values according to IEC 60127; WICKMANN values may be lower
2 not mentioned in the IEC 60127 standard; ratings are WICKMANN values
3 depending on application and mounting, the heating at the maximum ambient temperature in a closed fuseholder should be taken into consideration
4 please specify if CCEE is required when ordering
Note: Contact WICKMANN for individual I-t curves
IFault/IRated
→
Time in seconds
→
Rated Current / Amp Breaking Voltage Drop (max)1Power Dissipation (max)1Melting Integral (min) Approvals
Rated Voltage Code Capacity 100% x IRated 150% x IRated 1000% x IRated
(mV) (W) (A2s)
L ≅ 35A at
250VAC
cos ϕ = 1.0
L ≅ 40A ~
L ≅ 50A ~
2,3
2,3 L ≅ 63A ~
2,3
MINIATURE FUSES
32mA / 250V 0032 5000 1.6 0.01
40mA / • 0040 4000 1.6 0.011
50mA / • 0050 3500 1.6 0.02
63mA / • 0063 3000 1.6 0.026
80mA / • 0080 3000 1.6 0.052
100mA / • 0100 2500 1.6 0.073
125mA / • 0125 2000 1.6 0.13
160mA / • 0160 1900 1.6 0.22
200mA / • 0200 1500 1.6 0.3
250mA / • 0250 1300 1.6 0.32
315mA / • 0315 1100 1.6 1.1
400mA / • 0400 1000 1.6 2.4
500mA / • 0500 900 1.6 3.8
630mA / • 0630 300 1.6 7.5
800mA / • 0800 250 1.6 10
1.00A / • 1100 150 1.6 11
1.25A / • 1125 150 1.6 20
1.60A / • 1160 150 1.6 36
2.00A / • 1200 150 1.6 10
2.50A / • 1250 120 1.6 14
3.15A / • 1315 100 1.6 25
4.00A / • 1400 100 1.6 42
5.00A / • 1500 100 1.6 70
6.30A / • 1630 100 1.6 120
8.00A / • 1800 120 2.6 240
10.00A / • 2100 120 3.0 400
12.50A / • 2125 120 3.5 650
••••••
••••••
••••••
••••••
••••••
••••••
••••••
••••••
••••••
••••••
••••••
••••••
••••••
••••••
••••••
••••••
••••••
••••••
••••••
••••••
••••••
••••••
••••••
••••••
•
•
•
•Order Qty. Order- Series Amp Code Packaging
Information Number
1 9 5 0
23456789110
0.001
0.01
0.1
1
10
100
1,000
10,000
100,000
151.5
IE C 60127- 2/SS 3
(3 2 .. . 10 0 mA)
IE C 60 127 -2 /SS 3
( 12 5 m A ... 6.3 0 A )
Time -c u rre n t cha rac te ristic s
(Min -Max Lim it s)
VDE
SEMKO
BSI
IMQ
cURus
CCEE
4