www.clare.com
2R05
LCC110
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Absolute Maximum Ratings @ 25ºC
Parameter Min Max Unit
Blocking Voltage - 350 VP
Reverse Input Voltage - 5 V
Input control Current - 50 mA
Peak (10ms) - 1 A
Input Power Dissipation 1- 150 mW
Total Power Dissipation 2- 800 mW
Isolation Voltage, Input to Output 3750 - Vrms
Operating Temperature -40 +85 ºC
Storage Temperature -40 +125 ºC
1 Derate linearly 1.33mW / ºC.
2 Derate linearly 6.67mW / ºC.
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current
Continuous, AC/DC Confi guration - IL- - 120 mA
Peak t=10ms ILPK - - 350
On-Resistance, AC/DC Confi guration IL=120mA RON -2335
Ω
Off-State Leakage Current VL=350VPILEAK --1µA
Switching Speeds
Turn-On IF=8mA, VL=10V ton --4
ms
Turn-Off toff --4
Output Capacitance VL=50V, f=1MHz COUT -25-pF
Input Characteristics
Input Control Current IL=120mA IF--8mA
Input Dropout Current - IF0.4 0.7 - mA
Input Voltage Drop IF=8mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR--10μA
Common Characteristics
Capacitance, Input to Output - CI/O -3-pF
Note: If both poles operate simultaneously, then load current must be derated so as not to exceed package power dissipation value.
Electrical Characteristics @ 25ºC