SPECIFICATION
480W Three Phase Industrial DIN RAIL with PFC Function TDR-480 series
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.4
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
SAFETY STANDARDS
WORKING TEMP. Note.5
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
1200ms, 60ms/400VAC 800ms, 60ms/500VAC at full load
20ms / 400VAC 20ms / 500VAC at full load
Three-Phase 340 ~ 550VAC (Dual phase operation possible) 480 ~ 780VDC
47 ~ 63Hz
92.5%
0.85A/400VAC 0.7A/500VAC
56 ~ 65V
93%
COLD START 50A
<3.5mA / 530VAC
29 ~ 33V
Protection type : Constant current limiting, unit will shut down after 3 sec. ,re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
UL508, IEC60950-1 CB approved by UL approved
,EAC TP TC 004
-30 ~ +70 (Refer to "Derating Curve")℃
20 ~ 95% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 50 )
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
391.7K hrs min. Telcordia SR-332(Bellcore) ; 108.2K hrs min. MIL-HDBK-217F (25 )℃
85.5*125.2*128.5mm (W*H*D)
1.51Kg ; 8pcs/13Kg/1.16CUFT
TDR-480-48
48V
10A
0 ~ 10A
480W
150mVp-p
48 ~ 55V
±1.0%
±0.5%
±1.0%
TDR-480-24
24V
20A
0 ~ 20A
480W
150mVp-p
24 ~ 28V
±1.0%
±0.5%
±1.0%
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC O/P-DC OK(optional):0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25 / 70% RH℃
ENVIRONMENT
SAFETY &
EMC
(Note 4)
PROTECTION
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
1. All parameters NOT specially mentioned are measured at 400VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Dual phase operation is allowed under certain derating to output load.
Please refer to derating curves for details.
5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power.
In case the adjacent device is a heat source, 15mm clearance is recommended.
6. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
7. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
(as available on http://www.meanwell.com)
105 ~ 130% rated output power
POWER FACTOR (Typ.) PF 0.9/400VAC PF 0.88/500VAC at full load≧≧
File Name:TDR-480-SPEC 2020-01-04
Parameter
Parameter
ESD
Radiated Field
EFT / Burst
Surge
Conducted
Magnetic Field
Voltage Dips and Interruptions
Conducted
Radiated
Harmonic Current
Voltage Flicker
Standard
Standard
EN55032(CISPR32) / EN61204-3
EN61000-3-2
EN61000-3-3
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
Test Level / Note
Test Level / Note
Class B
Class B
Class A
-----
EMC IMMUNITY
EMC EMISSION
EN55024 , EN61204-3
Level 4, 15KV air ; Level 4, 8KV contact
Level 3
Level 3
Level 3
Level 4
>95% dip 0.5 periods, 30% dip 25
periods 95% interruptions 250 periods>
Level 4, 2KV / Line-Line, Level 4, 4KV/ Line-Earth
EN55032(CISPR32) / EN61204-3