www.clare.com
DS-LBB127-R04 1
LBB127
Dual Single-Pole,
Normally Closed OptoMOS® Relay
RoHS
2002/95/EC e3
Pb
Parameter Ratings Units
Blocking Voltage 250 VP
Load Current 200 mA
Max RON 10
Description
Pin Configuration
Switching Characteristics of
Normally Closed (Form B) Devices
Form-B
I
F
10%
90%
I
LOAD
t
on
t
off
Clare's LBB127 is a 250V, 200mA, 10 dual normally
closed (1-Form-B) Solid State Relay that comprises
two independently controlled, optically coupled
MOSFET switches.
The MOSFET switches and photovoltaic die use
Clare’s patented OptoMOS® architecture to provide
3750 Vrms of input-to-output isolation. The optically
coupled output is controlled by a highly efficient
GaAIAs infrared LED.
This dual single-pole OptoMOS relay provides a more
compact design solution than discrete single-pole
relays in a variety of applications, and saves board
space by incorporating both switches in a single 8-pin
package.
Applications
Features
3750Vrms Input/Output Isolation
Low Drive Power Requirements (TTL/CMOS
Compatible)
High Reliability
Arc-Free With No Snubbing Circuits
FCC Compatible
VDE Compatible
No EMI/RFI Generation
Small 8-Pin Package
Machine Insertable, Wave Solderable
Surface Mount Tape & Reel Versions Available
Telecommunications
Telecom Switching
Tip/Ring Circuits
Modem Switching (Laptop, Notebook, Pocket Size)
Hook Switch
Dial Pulsing
Ground Start
Ringing Injection
Instrumentation
Multiplexers
Data Acquisition
Electronic Switching
I/O Subsystems
Meters (Watt-Hour, Water, Gas)
Medical Equipment-Patient/Equipment Isolation
Security
Aerospace
Industrial Controls
Part # Description
LBB127 8-Pin DIP (50/Tube)
LBB127S 8-Pin Surface Mount (50/Tube)
LBB127STR 8-Pin Surface Mount (1,000/Reel)
LBB127P 8-Pin Flatpack (50/Tube)
LBB127PTR 8-Pin Flatpack (1,000/Reel)
Approvals
Ordering Information
1
2
3
4
8
7
6
5
+ Control - Switch #1
– Control - Switch #1
+ Control - Switch #2
– Control - Switch #2
Load - Switch #1
Load - Switch #1
Load - Switch #2
Load - Switch #2
UL Recognized Component: File E76270
CSA Certified Component: Certificate 1175739
EN/IEC 60950-1 Certified Component:
TUV Certificate B 09 07 49410 004
www.clare.com
2R04
LBB127
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current
Continuous 1-I
L- - 200 mA
Peak t =10ms ILPK - - 400
On-Resistance IL=200mA RON -810
Off-State Leakage Current VL=250VPILEAK --1A
Switching Speeds
Turn-On IF=5mA, VL=10V ton --5
ms
Turn-Off toff --5
Output Capacitance VL=50V, f=1MHz COUT -50-pF
Input Characteristics
Input Control Current IL=200mA IF--5mA
Input Dropout Current - IF0.4 0.7 - mA
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR--10A
Common Characteristics
Input to Output Capacitance - CI/O -3-pF
1 If both poles operate, then the load current must be derated so as not to exceed the package power dissipation value.
Parameter Ratings Units
Blocking Voltage 250 VP
Reverse Input Voltage 5 V
Input Control Current 50 mA
Peak (10ms) 1 A
Input Power Dissipation 1150 mW
Total Power Dissipation 2800 mW
Isolation Voltage, Input to Output 3750 Vrms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate linearly 1.33 mW / °C
2 Derate linearly 6.67 mW / °C
Absolute Maximum Ratings @ 25°C
Electrical Characteristics @ 25°C
LBB127
www.clare.com 3
R04
PERFORMANCE DATA*
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application
department.
Typical LED Forward Voltage Drop
(N=50, IF=5mA, TA=25ºC)
35
30
25
20
15
10
5
0
1.17 1.19 1.21 1.23 1.25
LED Forward Voltage Drop (V)
Device Count (N)
Typical Turn-On Time
(N=50, IF=5mA, IL=200mA, TA=25ºC)
0.05 0.09 0.130.03 0.07 0.11
Turn
-
On (ms)
Device Count (N)
25
20
15
10
5
0
Typical Turn-Off Time
(N=50, IF=5mA, IL=200mA, TA=25ºC)
0.75 1.35 1.950.45 1.05 1.60
Turn
-
Off (ms)
Device Count (N)
25
20
15
10
5
0
Typical IF for Switch Operation
(N=50, IL=200mA, TA=25ºC)
1.4 1.8 2.6 3.42.2 3.0
LED Current (mA)
Device Count (N)
25
20
15
10
5
0
Typical IF for Switch Dropout
(N=50, IL=200mA, TA=25ºC)
25
20
15
10
5
0
1.4 2.2 3.01.0 1.8 2.6
LED Current (mA)
Device Count (N)
Typical On-Resistance Distribution
(N=50, IF=5mA, IL=200mA, TA=25ºC)
25
20
15
10
5
0
5.325 5.495 5.665 6.0055.835 6.175
On
-
Resistance (:)
Device Count (N)
Typical Blocking Voltage Distribution
(N=50, IF=5mA, TA=25ºC)
25
20
15
10
5
0
310 314 318 322 326 330
Blocking Voltage (V)
Device Count (N)
Typical LED Forward Voltage Drop
vs. Temperature
Temperature (ºC)
LED Forward Voltage Drop (V)
1.8
1.6
1.4
1.2
1.0
0.8
-40 -20 0 20 40 60 80 120100
I
F
=50mA
I
F
=30mA
I
F
=20mA
I
F
=10mA
I
F
=5mA
Typical Turn-On
vs. LED Forward Current
(IL=200mA)
LED Forward Current (mA)
Turn-On (ms)
05 1015202530354045
0.060
0.050
0.040
0.030
0.020
0.010
0
50
Typical Turn-Off
vs. LED Forward Current
(IL=200mA)
LED Forward Current (mA)
Turn-Off (ms)
05 1015202530354045
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
50
www.clare.com
4R04
LBB127
PERFORMANCE DATA*
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application
department.
Typical Turn-On vs. Temperature
(IF=5mA, IL=200mA)
Temperature (ºC)
Turn-On (ms)
-40
0.12
0.10
0.08
0.06
0.04
0.02
0
-20 0 20 40 60 80 100
Typical Turn-Off vs. Temperature
(IL=200mA)
Temperature (ºC)
Turn-Off (ms)
-40
2.5
2.0
1.5
1.0
0.5
0
-20 0 20 40 60 80 100
IF=5mA
IF=10mA
IF=20mA
Typical IF for Switch Operation
vs. Temperature
(IL=200mA)
Temperature (ºC)
LED Current (mA)
-40
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0
-20 0 20 40 60 80 100
Typical IF for Switch Dropout
vs. Temperature
(IL=200mA)
Temperature (ºC)
LED Current (mA)
-40
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0
-20 0 20 40 60 80 100
Typical Load Current
vs. Temperature
Temperature (ºC)
Load Current (mA)
250
200
150
100
50
0
-40 -20 0 20 40 60 80 120100
Typical On-Resistance
vs. Temperature
(IF=5mA, IL=200mA)
Temperature (ºC)
On-Resistance (:)
-40
8.0
7.0
6.0
5.0
4.0
3.0
2.0
1.0
0
-20 0 20 40 60 80 100
Typical Load Current
vs. Load Voltage
(TA=25ºC)
Load Voltage (V)
Load Current (mA)
200
150
100
50
0
-50
-100
-150
-200
-1.2 -0.8 -0.4 0 0.4 0.8 1.2
Typical Blocking Voltage
vs. Temperature
(IF=5mA)
Temperature (ºC)
Blocking Voltage (VRMS)
-40
400
350
300
250
200
150
100
50
0
-20 0 20 40 60 80 100
Typical Leakage vs. Temperature
Measured across Pins 5 & 6 or 7 & 8
Temperature (ºC)
Leakage (A)
-40
0.045
0.040
0.035
0.030
0.025
0.020
0.015
0.010
0.005
0
-20 0 20 40 60 80 100
Energy Rating Curve
Time
Load Current (A)
1.2
1.0
0.8
0.6
0.4
0.2
0
10Ps 1ms 100ms 10s100Ps 10ms 1s 100s
LBB127
www.clare.com 5
R04
Manufacturing Information
Moisture Sensitivity
All plastic encapsulated semiconductor packages are susceptible to moisture ingression. Clare classified all
of its plastic encapsulated devices for moisture sensitivity according to the latest version of the joint industry
standard, IPC/JEDEC J-STD-020, in force at the time of product evaluation. We test all of our products to the
maximum conditions set forth in the standard, and guarantee proper operation of our devices when handled according
to the limitations and information in that standard as well as to any limitations set forth in the information or standards
referenced below.
Failure to adhere to the warnings or limitations as established by the listed specifications could result in reduced
product performance, reduction of operable life, and/or reduction of overall reliability.
This product carries a Moisture Sensitivity Level (MSL) rating as shown below, and should be handled according to
the requirements of the latest version of the joint industry standard IPC/JEDEC J-STD-033.
Device Moisture Sensitivity Level (MSL) Rating
LBB127 / LBB127S / LBB127P MSL 1
ESD Sensitivity
This product is ESD Sensitive, and should be handled according to the industry standard JESD-625.
Reflow Profile
This product has a maximum body temperature and time rating as shown below. All other guidelines of J-STD-020
must be observed.
Device Maximum Temperature x Time
LBB127 / LBB127S 250ºC for 30 seconds
LBB127P 260ºC for 30 seconds
Board Wash
Clare recommends the use of no-clean flux formulations. However, board washing to remove flux residue is acceptable.
Since Clare employs the use of silicone coating as an optical waveguide in many of its optically isolated products,
the use of a short drying bake may be necessary if a wash is used after solder reflow processes. Chlorine-based or
Fluorine-based solvents or fluxes should not be used. Cleaning methods that employ ultrasonic energy should not be
used.
RoHS
2002/95/EC e3
Pb
www.clare.com
6R04
LBB127
MECHANICAL DIMENSIONS
LBB127
LBB127S
LBB127P
Dimensions
mm
(inches)
PCB Hole Pattern
2.540 ± 0.127
(0.100 ± 0.005)
6.350 ± 0.127
(0.250 ± 0.005)
9.144 ± 0.508
(0.360 ± 0.020)
0.457 ± 0.076
(0.018 ± 0.003)
9.652 ± 0.381
(0.380 ± 0.015)
7.239 TYP.
(0.285)
7.620 ± 0.254
(0.300 ± 0.010)
4.064 TYP
(0.160)
0.889 ± 0.102
(0.035 ± 0.004)
8-0.800 DIA.
(8-0.031 DIA.) 2.540 ± 0.127
(0.100 ± 0.005)
7.620 ± 0.127
(0.300 ± 0.005)
7.620 ± 0.127
(0.300 ± 0.005)
6.350 ± 0.127
(0.250 ± 0.005)
3.302 ± 0.051
(0.130 ± 0.002)
0.254 TYP
(0.01)
Dimensions
mm
(inches)
PCB Land Pattern
9.398 ± 0.127
(0.370 ± 0.005)
6.350 ± 0.127
(0.250 ± 0.005)
2.540 ± 0.127
(0.100 ± 0.005)
7.620 ± 0.254
(0.300 ± 0.010)
0 MIN / 0.102 MAX
(0 MIN / 0.004 MAX)
2.286 MAX.
(0.090 MAX.)
0.203 ± 0.013
(0.008 ± 0.0005)
0.635 ± 0.127
(0.025 ± 0.005)
9.652 ± 0.381
(0.380 ± 0.015)
0.457 ± 0.076
(0.018 ± 0.003)
2.159 ± 0.025
(0.085 ± 0.001)
2.54
(0.10)
8.70
(0.3425)
1.55
(0.0610)
0.65
(0.0255)
0.864 ± 0.120
(0.034 ± 0.004)
Dimensions
mm
(inches)
PCB Land Pattern
2.540 ± 0.127
(0.100 ± 0.005)
9.652 ± 0.381
(0.380 ± 0.015)
6.350 ± 0.127
(0.250 ± 0.005)
9.525 ± 0.254
(0.375 ± 0.010)
0.457 ± 0.076
(0.018 ± 0.003)
0.813 ± 0.120
(0.032 ± 0.004)
4.445 ± 0.127
(0.175 ± 0.005)
7.620 ± 0.254
(0.300 ± 0.010)
0.635 ± 0.127
(0.025 ± 0.005)
0.254 ± 0.127
(0.010 ± 0.0005)
2.54
(0.10)
8.90
(0.3503)
1.65
(0.0649)
0.65
(0.0255)
3.302 ± 0.051
(0.130 ± 0.002)
Clare, Inc. makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications and
product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in Clare’s Standard Terms and Conditions of Sale,
Clare, Inc. assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability, fitness for
a particular purpose, or infringement of any intellectual property right.
The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other applications
intended to support or sustain life, or where malfunction of Clare’s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. Clare,
Inc. reserves the right to discontinue or make changes to its products at any time without notice.
Specification: DS-LBB127-R04
©Copyright 2011, Clare, Inc.
OptoMOS® is a registered trademark of Clare, Inc.
All rights reserved. Printed in USA.
5/25/2011
For additional information please visit our website at: www.clare.com
7
LBB127
MECHANICAL DIMENSIONS
LBB127S Tape & Reel
LBB127P Tape & Reel
Dimensions
mm
(inches)
User Direction of Feed
NOTES:
1. Dimensions carry tolerances of EIA Standard 481-2
2. Tape complies with all “Notes” for constant dimensions listed on page 5 of EIA-481-2
Embossment
Embossed Carrier
Top Cover
Tape Thickness
0.102 MAX.
(0.004 MAX.)
330.2 DIA.
(13.00 DIA.)
K1
=4.20
(0.165)
0
K =4.90
(0.193)
P=12.00
(0.472)
W=16.00
(0.63)
Bo=10.30
(0.406)
Ao=10.30
(0.406)
Dimensions
mm
(inches)
NOTES:
1. All dimensions carry tolerances of EIA Standard 481-2
2. The tape complies with all “Notes” for constant dimensions listed on page 5 of EIA-481-2
Embossment
Embossed Carrier
Top Cover
Tape Thickness
0.102 MAX.
(0.004 MAX.)
330.2 DIA.
(13.00 DIA.)
User Direction of Feed
P = 12.00
(0.472)
W = 16.00
(0.63)
Bo = 10.30
(0.406)
Ao = 10.30
(0.406)
K1 = 2.00
(0.079)
K0 = 2.70
(0.106)