Data Sheet FlatPAC-ENTM EN Compliant, Autoranging Switcher Features * EN 61000-3-2 harmonic current compliance * Low profile package (1.4"/35,6mm) * Output power to 500W (425W for EN compliance) * Up to 4 user specifiable outputs * "Autosense" feature * Compliant to EN 55022, Class A, EN 55022, Class B (may require optional in-line filter), EN 61000-4-4 and EN 61000-4-5 * Rugged: Meets MIL-STD-810E for vibration * Drop-in upgrade to our "2up" FlatPAC * RS-232 microcontroller interface * Safety agency approvals: TUV, cULus, CE 1.4"H x 5.0"W x 9.2"L 35,6 x 127,0 x 233,7 mm Up to 500W 1 to 4 Outputs Overview With a power density greater than 7W/in3, Westcor's FlatPAC-EN is an ultra low profile, compact, EN compliant autoranging AC-DC switcher. It is capable of providing up to 500 Watts from up to 4 isolated outputs. For maximum versatility and flexibility, the FlatPAC-EN can be configured with standard Vicor DC-DC converter modules - full, half and quarter brick sizes. These modules cover the entire range of outputs from 1 to 100Vdc and 25 to 500 Watts, as well as an array of non-standard voltages. The optimum FlatPACEN solution can be factory configured based on your exact voltage and power requirements. For conducted EMI, the FlatPAC-EN conforms with FCC Class A and B, and EN 55022, Class A and B. Some configurations may require our optional external in-line filter to meet EN 55022 Class B. Further, besides meeting the cULus, TUV and CE safety agency approvals, the FlatPAC-EN complies with harmonic current limits per EN 61000-3-2, Electrical Fast Transient/Burst per EN 61000-4-4 and Surge Immunity per EN 61000-4-5. For harmonic current compliance to EN 61000-3-2, do not exceed input current of 3.33 A rms at 230Vac, 50 Hz. Part Numbering FL X1 - X2 X3 - XXX - E Number of 1st Gen modules Product Prefix FL FlatPAC-EN Number of Output Voltages Factory Assigned Number of 2nd Gen modules Extended Temperature Range Version (Optional) Autosense Feature* This is a new feature implemented in all converter slots in the FlatPAC-EN. If remote sense connections are not needed or are inadvertently not made, no local sense connections are necessary. Simply connect the output(s) to the load and the converter(s) will automatically operate in the local sense mode. If remote sense connections are made, the unit will operate in remote sense mode. *Applies to outputs utilizing Maxi or Mini size converters. Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Westcor Division 408-522-5280 FlatPAC-EN Set your site on VICOR at www.vicorpower.com Rev. 1 Page 1 of 8 DC Output Selections The tables below show a sampling of some of the most popular standard outputs that can be configured into the FlatPAC-EN. Available Power (W) per Package Size Output Voltage Maxi 2nd Gen 160 264 400 500 500 500 500 500 2Vdc 3.3Vdc 5Vdc 12Vdc 15Vdc 24Vdc 28Vdc 48Vdc Mini 1st Gen 80 132 200 200 200 200 200 200 60 99 150 150 150 150 150 150 2nd Gen 100 150 200 250 250 250 250 250 Micro 1st Gen 40 66 100 100 100 100 100 100 2nd Gen 50 75 100 150 150 150 150 150 30 50 75 75 75 75 75 75 FlatPAC-EN Configurations Vicor's DC-DC converter modules are used to populate the FlatPAC-EN. There are several configurations available depending on module size, power limitation and location of the MiniHAM*. The two-output FlatPAC-EN contains 1 Maxi and 1 Mini. The three-output FlatPAC-EN contains 3 Minis. The four output FlatPAC-EN contains 1 Mini and 3 Micros. See below. FlatPAC-EN Configurations Maximum Total Output Power = 500W (425W for EN61000-3-2 Compliance) 2 Output** 4 Output 3 Output MiniHAM Mini MiniHAM Mini MiniHAM M3 M4 Maxi Mini M1 M1 M2 M2 Mini Mini M1 M2 M1 M2 M3 Micro Micro Micro M1 M2 M3 M1 M2 M3 M4 Note: The FlatPAC-EN is limited to a maximum output power of 500W regardless of the module capability. For example, if three Mini modules are used, the maximum output power for the FlatPAC-EN is still 500W irrespective of the maximum output power of the modules. For EN 61000-3-2 harmonic current compliance, input current of 3.33 A rms should not be exceeded. * The MiniHAM is a passive harmonic attenuator specifically designed for EN compliance. Unlike active PFC solutions, the MiniHAM generates no EMI, greatly simplifying and reducing system noise filtering requirements. It is also considerably smaller and more efficient than active alternatives and improves the unit's MTBF. It will provide harmonic current compliance at 230Vac input at up to 425W of output power. ** For a single output configuration either M1 or M2 is used. Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Westcor Division 408-522-5280 FlatPAC-EN Set your site on VICOR at www.vicorpower.com Rev. 1 Page 2 of 8 Performance Specifications The following are typical performance specifications at room ambient temperature, nominal line voltage (115/230Vac) and 75% load on all outputs, unless specified otherwise. For detail specifications, consult the FlatPAC-EN Design Guide available online at (vicorpower.com). INPUT CHARACTERISTICS Parameter Typ Units 90-132/180-264 Vac 47-63 Hz 250-380 Vdc 0.2 % @ 115Vac 8 A rms @ 230Vac 8 A rms @ 115Vac 12/15 ms @ 230Vac 16/18 ms 500/400 W Notes AC Input Voltage Frequency DC Input Line Regulation Derates to 260W @ 90Vac, 400W @ 180Vac From low line to high line Inrush Current Ride Through Time @ Load Conducted EMI/RFI FCC Class A, EN 55022 Class A FCC Class B, EN 55022 Class B Power Factor EN 55022 Class B may need external optional in-line filter > 0.70 Harmonic Current Limits EN 61000-3-2/A14 Transient Burst Immunity EN 61000-4-4 Surge Immunity EN 61000-4-5 Voltage Dips EN 61000-4-11 >75% load Input current of 3.33A rms max. at 230Vac, 50Hz Criteria B Dielectric Withstand Primary to Chassis GND 1,500 Vrms Primary to Secondary 3,000 Vrms 500 Vrms Secondary to Chassis GND Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Westcor Division 408-522-5280 FlatPAC-EN Set your site on VICOR at www.vicorpower.com Rev. 1 Page 3 of 8 Performance Specifications Cont. OUTPUT CHARACTERISTICS Parameter Typ Units Setpoint Accuracy 0.5 % Notes Of Vnom Load Regulation 0.2 % No Load to full load Temperature Regulation 0.005 %/C Long Term Drift 0.02 %/khr 10Vout 100 mV 20MHz band width >10Vout 1.0 % 20MHz band width 1st Gen Modules 50-110 %Vout 10% on 10 - 15 Vout 2nd Gen Modules 10-110 %Vout Preload may be required Autosense (See page 1) -20C to +65C Output Ripple & Noise Voltage Trim Range Remote Sense Compensation 0.5 Vdc OVP Set Point 125 %Vout Not available on 1st Gen Minis Current Limit 115 %Imax Autorecovery Typ Units Notes -20 to +100 -40 to +100 C C Standard version Extended range option* -20 to +70 -20 to +90 C C See derating curves in Design Guide 75 for 1st Gen Maxi modules ENVIRONMENTAL CHARACTERISTICS Parameter Storage Temperature Operating Temperature(standard and extended)* Ambient Air Case Temperature Vibration MIL-STD-810E, Category 10 Minimum Integrity Test see note Safety Approvals cULus, TUV, CE *Extended temperature range option includes module burn-in and temperature cycling. MECHANICAL CHARACTERISTICS Parameter Typ Units Weight 3.4 1.5 lbs kg Overall Dimensions Notes 9.2 x 5.0 x 1.4 in LxWxH 233,7 x 127,0 x 35,6 mm LxWxH Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Westcor Division 408-522-5280 FlatPAC-EN Set your site on VICOR at www.vicorpower.com Rev. 1 Page 4 of 8 Mechanical Diagram 9.20 233,69 MBJ1 A/C INPUT 2 3 MATING CONNECTOR: HOUSING: MOLEX (39-01-4051) SOCKET CRIMP 16 AWG: MOLEX (39-00-0090) CRIMP TOOL: MOLEX (11-01-0199) 1.40 35,59 MBJ1 1 GN 0.03 0,77 N/C L2/N N/C MOUNTING HOLES 4X #8-32 x 0.250 OR M4 x 6mm MAX LG FROM OUTSIDE OF POWER SUPPLY MOUNTING HOLES 4X #8-32 x 0.125 OR M4 x 3mm MAX LG FROM OUTSIDE OF POWER SUPPLY L1 OUTPUTS J2 M1 & M2 4.000 101,60 4.563 115,89 OUTPUTS J3 M3 & M4 0.50 12,70 QUADRUPLE OUTPUT See page 6 and 7 for detailed output connection information. 0.219 5,56 5.825 147,96 PIN 1 1 CBJ1 (12 PIN) AIR FLOW 5.450 138,43 8.500 215,90 0.38 9,53 PIN REF DESCRIPTION CBJ1 CBJ2 CBJ3 CBJ4 CBJ5 CBJ6 CBJ7 CBJ8 CBJ9 CBJ10 CBJ11 CBJ12 SGND N/C ACOK TX RX E/D-4 E/D-3 E/D-2 E/D-1 GSD N/C +5VS SIGNAL GROUND N/C AC POWER OK TRANSMIT 4 RECEIVE ENABLE/DISABLE ENABLE/DISABLE ENABLE/DISABLE ENABLE/DISABLE GENERAL SHUTDOWN N/C +5V @ 300mA CBJ1 E/D INTERFACE CONNECTOR 3 2 MATING CONNECTOR: HOUSING: MOLEX (50-57-9412) SOCKET CRIMP 24-30 AWG: MOLEX (16-02-0097) CRIMP TOOL: MOLEX (11-01-0209) NOTES: UNLESS OTHERWISE SPECIFIED 1 REFERENCE DESIGNATION MB CB MOTHER BOARD CONTROL BOARD 2 CONNECTOR PART NUMBERS SPECIFIED ARE MOLEX OR EQUIVALENT 3 A COMPLETE SET OF MATING CONNECTORS CAN BE PURCHASED FROM WESTCOR BY SPECIFYING CONNECTOR KIT P/N 19-130044 4 CBJ4 AND CBJ5 ARE PART OF THE RS-232 MICROCONTROLLER FUNCTIONS. SEE FLATPAC-EN DESIGN GUIDE (AVAILABLE ONLINE AT VICORPOWER.COM) FOR DETAILED INFORMATION. Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Westcor Division 408-522-5280 FlatPAC-EN Set your site on VICOR at www.vicorpower.com Rev. 1 Page 5 of 8 FlatPAC-EN OUTPUT CONNECTORS A. SINGLE OR DUAL OUTPUT J1/J2 SENSE/TRIM PIN CONNECTOR -V OUT 10-32 OUTPUT STUDS 1 2 3 TRIM + SENSE - SENSE MATING CONNECTOR: HOUSING: MOLEX P/N 50-57-9403 TERMINALS: MOLEX P/N 16-02-0103 USE CRIMP TOOL: MOLEX P/N 11-01-0208 10-32 STUDS OUTPUT M1 OUTPUT M2 J1 - + - M1 M1 J2 + +V OUT M2 M2 SINGLE OR DUAL OUTPUT B. TRIPLE OUTPUT Output M1 (Using 1 Mini) J2 J2 (18 PIN OUTPUT, SENSE AND TRIM PIN CONNECTOR) 9 18 8 17 PIN 7 16 1 2 3 4 5 6 7 8 9 6 15 5 14 4 13 3 12 2 11 1 10 DESCRIPTION PIN DESCRIPTION N/C N/C N/C N/C N/C TRIM M1 +V OUT M1 +V OUT M1 -V OUT M1 10 11 12 13 14 15 16 17 18 N/C N/C N/C + SENSE M1 N/C - SENSE M1 +V OUT M1 - V OUT M1 - V OUT M1 MATING CONNECTOR: 18 PIN HOUSING: MOLEX (39-01-2180) TERMINAL FEM CRIMP 18-24 AWG: MOLEX (39-00-0039) USE CRIMP TOOL: MOLEX (11-01-0197) OUTPUTS M2 & M3 OUTPUT M1 18 9 J2 10 18 1 9 10 J3 1 TRIPLE OUTPUT Outputs M2 and M3 (Using 2 Minis) J3 J3 (18 PIN OUTPUT, SENSE AND TRIM PIN CONNECTOR) 9 18 8 17 PIN 7 16 1 2 3 4 5 6 7 8 9 6 15 5 14 4 13 3 12 2 11 1 10 DESCRIPTION PIN DESCRIPTION +V OUT M3 -V OUT M3 -V OUT M3 + SENSE M3 - SENSE M3 TRIM M2 +V OUT M2 +V OUT M2 -V OUT M2 10 11 12 13 14 15 16 17 18 +V OUT M3 +V OUT M3 -V OUT M3 + SENSE M2 TRIM M3 - SENSE M2 +V OUT M2 - V OUT M2 - V OUT M2 Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Westcor Division 408-522-5280 FlatPAC-EN Set your site on VICOR at www.vicorpower.com Rev. 1 Page 6 of 8 FLATPAC-EN OUTPUT CONNECTORS (continued) C. QUADRUPLE OUTPUT Outputs M1 and M2 (Using 2 Micros) J2 J2 (18 PIN OUTPUT, SENSE AND TRIM PIN CONNECTOR) 9 18 8 17 7 16 6 15 5 14 4 13 3 12 2 11 1 10 PIN 1 2 3 4 5 6 7 8 9 DESCRIPTION PIN DESCRIPTION +V OUT M2 -V OUT M2 -V OUT M2 +V OUT M2 - V OUT M2 TRIM M1 +V OUT M1 +V OUT M1 -V OUT M1 10 11 12 13 14 15 16 17 18 +V OUT M2 +V OUT M2 -V OUT M2 + V OUT M1 TRIM M2 - V OUT M1 +V OUT M1 - V OUT M1 - V OUT M1 MATING CONNECTOR: 18 PIN HOUSING: MOLEX (39-01-2180) TERMINAL FEM CRIMP 18-24 AWG: MOLEX (39-00-0039) USE CRIMP TOOL: MOLEX (11-01-0197) 18 J2 9 10 1 OUTPUTS M1 & M2 18 9 J3 10 1 OUTPUTS M3 & M4 QUADRUPLE OUTPUT Outputs M3 and M4 (Using 1 Micro and 1 Mini) J3 J3 (18 PIN OUTPUT, SENSE AND TRIM PIN CONNECTOR) 9 18 8 17 PIN DESCRIPTION 7 16 1 2 3 4 5 6 7 8 9 +V OUT M4 -V OUT M4 -V OUT M4 + SENSE M4 - SENSE M4 TRIM M3 +V OUT M3 +V OUT M3 -V OUT M3 6 15 5 14 4 13 3 12 2 11 1 10 PIN DESCRIPTION 10 11 12 13 14 15 16 17 18 +V OUT M4 +V OUT M4 -V OUT M4 + V OUT M3 TRIM M4 - V OUT M3 +V OUT M3 - V OUT M3 - V OUT M3 Note: Additional technical information including temperature derating curves, installation instructions, mounting holes, in-line filter, RS-232 microcontroller features covered in the FlatPAC-EN Design Guide available online at vicorpower.com. FLATPAC-EN ACCESSORIES The following accessories are available for the FlatPAC-EN: Connector Kits FlatPAC-EN 19-130044 Current Share Boards Used for increased output power or redundancy FlatPAC-ENs with 1st Gen Modules FlatPAC-ENs with 2nd Gen Modules CSB01 CSB02 In-line Filter In-line Filter IF1232 Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Westcor Division 408-522-5280 FlatPAC-EN Set your site on VICOR at www.vicorpower.com Rev. 1 Page 7 of 8 Vicor's comprehensive line of power solutions includes high density AC-DC and DC-DC modules and accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems. Information furnished is believed to be accurate and reliable. However, no responsibility is assumed for its use. No license is granted by implication or otherwise under any patent or patent rights. Products are not designed to be used in applications, such as life support systems, wherein a failure or malfunction could result in injury or death. All sales are subject to our standard Terms and Conditions of Sale, which are available upon request. Specifications are subject to change without notice. The latest data is available on the Vicor website at vicorpower.com. Westcor, a division of Vicor, designs and builds configurable power supplies incorporating Vicor's high density DC-DC converters and accessory components. Westcor's product line includes: * * * * * * PFC Mini PFC Micro PFC MicroS Autoranging MegaPAC Mini MegaPAC PFC MegaPAC * * * * * PFC MegaPAC-EL (/Low Noise) 3 Phase/4kW MegaPAC 3 Phase/4kW MegaPAC-EL (Low Noise) ConverterPACs FlatPAC-EN See Design Guides for detailed information about all Westcor products. They can be downloaded in PDF format from the website. Vicor Corporation 25 Frontage Road, Andover, MA, 01810 978-470-2900, Fax: 978-475-6715 Westcor Division of Vicor 560 Oakmead Parkway, Sunnyvale, CA 94085 800-735-6200, 408-522-5280, Fax: 408-774-5555 vicorpower.com Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Westcor Division 408-522-5280 FlatPAC-EN Set your site on VICOR at www.vicorpower.com P/N 26318 Rev. 1 3/03/10M