TQ SMD
SPECIFICATIONS
LOW-PROFILE
SURFACE-MOUNT RELAY
TQ SMD RELAYS
TESTING
mm inch
RoHS Directive compatibility information
http://www.nais-e.com/
FEATURES
•Low-profile: 6 mm .236 inch
(Tape height: max. 6.5 mm .256 inch)
•Tape and reel package is available as standard packing style
• Surge withstand between contacts and coil: 2,500 V
• Breakdown voltage between contacts and coil: 1,500 V
• Capacity: 2 A
• High sensitivity:
2 Form C; 140 mW power consumption (Single side stable type)
Contact
Note:
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load. (SX relays are available for low level load switching [10V DC, 10mA
max. level])
Remarks
* Specifications will vary with foreign standards certification ratings.
*1Measurement at same location as “Initial breakdown voltage” section.
*2By resistive method, nominal voltage applied to the coil; contact carrying current:
2 A.
*3Nominal voltage applied to the coil, excluding contact bounce time.
*4Nominal voltage applied to the coil, excluding contact bounce time without diode.
*5Half-wave pulse of sine wave: 6 ms; detection time: 10 µs
*6Half-wave pulse of sine wave: 6 ms
*7Detection time: 10 µs
*8Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT .
Characteristics
Arrangement 2 Form C
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A) 75 mΩ
Contact material Au-clad AgNi type
Rating
Nominal switching capacity
(resistive load)
2 A 30 V DC,
0.5 A 125 V AC
Max. switching power
(resistive load) 60 W, 62.5 VA
Max. switching voltage 220 V DC, 125 V AC
Max. switching current 2 A
Min. switching capacity
(Reference value)#1 10 µA 10 mV DC
Nominal
operating
power
Single side stable
140 mW (1.5 to 12 V DC)
200 mW (24 V DC)
300 mW (48 V DC)
1 coil latching 70 mW (1.5 to 12 V DC)
100 mW (24 V DC)
2 coil latching 140 mW (1.5 to 12 V DC)
200 mW (24 V DC)
Expected
life (min.
operations)
Mechanical (at 180 cpm) 108
Electrical
(at 20 cpm)
2 A 30 V DC
resistive 105
1 A 30 V DC
resistive 2×105
0.5 A 125 V AC
resistive 105
Initial insulation resistance*1Min. 1,000 MΩ (at 500 V DC)
Initial
breakdown
voltage
Between open
contacts
1,000 Vrms for 1 min.
(Detection current: 10 mA)
Between contact sets 1,500 Vrms for 1 min.
(Detection current: 10 mA)
Between contact and
coil
1,500 Vrms for 1 min.
(Detection current: 10 mA)
Initial surge
voltage
Between open
contacts
(10×160 µs)
1,500 V (FCC Part 68)
Between contacts and
coil (2×10 µs) 2,500 V (Telcordia)
Temperature rise*2 (at 20°C) Max. 50°C
Operate time [Set time]*3 (at 20°C) Max. 4 ms [Max. 4 ms]
Release time [Reset time]*4
(at 20°C) Max. 4 ms [Max. 4 ms]
Shock resistance Functional*5Min. 750 m/s2 {75 G}
Destructive*6Min. 1,000 m/s2 {100 G}
Vibration resistance
Functional*7200 m/s2 {20G}, 10 to 55 Hz
at double amplitude of 3.3 mm
Destructive 294 m/s2 {30G}, 10 to 55 Hz
at double amplitude of 5 mm
Conditions for
operation, transport
and storage*8
(Not freezing and
condensing at low
temperature)
Ambient
temperature
–40°C to +85°C*3
–40°F to +185°F
Humidity 5 to 85% R.H.
Unit weight Approx. 2 g .071 oz
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.