1-134
Part Minimum
Number Intensity Color
HLMP- Application (mcd) at 10 mA (Material)
1300 General Purpose 1.3 High Efficiency
1301 General Purpose 2.1
1302 High Ambient 3.4
1385 Premium Lamp 8.6
K400 General Purpose 1.3 Orange
K401 High Ambient 2.1
K402 Premium Lamp 3.4
1400 General Purpose 1.4 Yellow
1401 General Purpose 2.2
1402 High Ambient 3.6
1485 Premium Lamp 5.7
1503 General Purpose 1.0 Green
1523 High Ambient 2.6
1585 Premium Lamp 4.2
K600[1] General Purpose 1.0 Emerald Green
(GaP)
Note:
1. Please refer to Application Note 1061 for information comparing standard green and
emerald green light output degradation.
H
T-1 (3 mm) Diffused
LED Lamps
Technical Data
Features
• High Intensity
• Choice of 4 Bright Colors
High Efficiency Red
Orange
Yellow
High Performance Green
• Popular T-1 Diameter
Package
• Selected Minimum
Intensities
• Wide Viewing Angle
• General Purpose Leads
• Reliable and Rugged
• Available on Tape and Reel
Description
This family of T-1 lamps is widely
used in general purpose indicator
applications. Diffusants, tints, and
optical design are balanced to
yield superior light output and
wide viewing angles. Several
intensity choices are available in
each color for increased design
flexibility.
Package Dimensions
HLMP-130X Series
HLMP-1385
HLMP-140X Series
HLMP-1485
HLMP-1503
HLMP-1523
HLMP-1585
HLMP-K40X Series
HLMP-K600
Red
(GaAsP on
GaP)
(GaAsP on
GaP)
(GaAsP on
GaP)
(GaP)
5964-9374E
1-135
Absolute Maximum Ratings at TA = 25°C
Parameter HER/Orange Yellow Green Units
Peak Forward Current 90 60 90 mA
Average Forward Current[1] 25 20 25 mA
DC Current[2] 30 20 30 mA
Reverse Voltage (IR = 100 µA) 5 5 5 V
Transient Forward Current[4] 500 500 500 mA
(10 µsec Pulse)
LED Junction Temperature 110 110 110 °C
Operating Temperature Range -55 to +100 -55 to +100 -20 to +100 °C
Storage Temperature Range -55 to +100
Lead Soldering Temperature 260°C for 5 seconds
[1.6 mm (0.063 in.) from body]
Notes:
1. See Figure 5 (HER/Orange), 10 (Yellow), or 15 (Green/Emerald Green) to establish pulsed operating conditions.
2. For Red, Orange, and Green series derate linearly from 50°C at 0.5 mA/°C. For Yellow series derate linearly from 50°C at 0.2 mA/°C.
3. For Red, Orange, and Green series derate power linearly from 25°C at 1.8 mW/°C. For Yellow series derate power linearly from 50°C at
1.6 mW/°C.
4. The transient peak current is the maximum non-recurring peak current that can be applied to the device without damaging the LED
die and wirebond. It is not recommended that the device be operated at peak currents beyond the peak forward current listed in the
Absolute Maximum Ratings.
Electrical Characteristics at TA = 25°C
Device Test
Symbol Description HLMP- Min. Typ. Max. Units Conditions
IVLuminous Intensity High Efficiency Red
1300 1.3 5.0 mcd IF = 10 mA
1301 2.1 5.5
1302 3.4 7.0
1385 8.6 11.0
Orange
K400 1.3 5.0
K401 2.1 5.5
K402 3.4 7.0
Yellow
1400 1.4 5.0
1401 2.2 6.0
1402 3.6 7.0
1485 5.7 10.0
Green
1503 1.0 5.0
1523 2.6 7.0
1585 4.2 8.5
Emerald Green
K600 1.0 4.5
1-136
Electrical Characteristics at TA = 25°C (cont.)
Device Test
Symbol Description HLMP- Min. Typ. Max. Units Conditions
2θ1/2Included Angle Between All 60 Deg. IF = 10 mA
Half Luminous Intensity See Note 1
Points
λPEAK Peak Wavelength High Efficiency Red 635 nm Measurement
Orange 600 at Peak
Yellow 583
Green 565
Emerald Green 558
λdDominant Wavelength High Efficiency Red 626 nm See Note 2
Orange 602
Yellow 585
Green 569
Emerald Green 560
∆λ1/2 Spectral Line Halfwidth High Efficiency Red 40 nm
Yellow 36
Green 28
Emerald Green 24
τsSpeed of Response High Efficiency Red 90 ns
Orange 280
Yellow 90
Green 500
Emerald Green 3100
C Capacitance High Efficiency Red 11 pF VF = 0;
Orange 4 f = 1 MHz
Yellow 15
Green 18
Emerald Green 35
RθJ-PIN Thermal Resistance All 290 °C/W Junction to
Cathode Lead
V
FForward Voltage HER/Orange 1.5 1.9 2.4 V IF = 10 mA
Yellow 1.5 2.0 2.4
Green 1.5 2.1 2.7
Emerald Green 2.1 2.7
VRReverse Breakdown All 5.0 V IR = 100 µA
Voltage
ηVLuminous Efficacy High Efficiency Red 145 lumens See Note 3
Orange 380 Watt
Yellow 500
Green 595
Emerald Green 655
Notes:
1. θ1/2 is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
2. The dominant wavelength, λd, is derived from the CIE chromaticity diagram and represents the single wavelength which defines the
color of the device.
3. Radiant intensity, Ie, in watts/steradian, may be found from the equation Ie= Iv/ηv, where Iv is the luminous intensity in candelas and ηv
is the luminous efficacy in lumens/watt.
1-137
Figure 5. Maximum Tolerable Peak
Current vs. Pulse Duration. (IDC MAX
as per MAX Ratings).
Figure 6. Relative Luminous Intensity vs. Angular Displacement.
Figure 3. Relative Luminous Intensity
vs. DC Forward Current.
Figure 2. Forward Current vs.
Forward Voltage Characteristics. Figure 4. Relative Efficiency
(Luminous Intensity per Unit Current)
vs. Peak LED Current.
T-1 High Efficiency Red, Orange Diffused Lamps
Figure 1. Relative Intensity vs. Wavelength.
ORANGE AlGaAs RED
HIGH EFFICIENCY RED
WAVELENGTH – nm
RELATIVE INTENSITY
1.0
0.5
0
500 550 600 650 700 750
YELLOW
EMERALD GREEN
HIGH
PERFORMANCE
GREEN
T = 25° C
A
1-138
T-1 Yellow Diffused Lamps
Figure 10. Maximum Tolerable Peak
Current vs. Pulse Duration. (IDC MAX
as per MAX Ratings).
Figure 11. Relative Luminous Intensity vs. Angular Displacement.
Figure 7. Forward Current vs.
Forward Voltage Characteristics. Figure 8. Relative Luminous Intensity
vs. Forward Current. Figure 9. Relative Efficiency
(Luminous Intensity per Unit Current)
vs. Peak Current.
1-139
T-1 Green/Emerald Green Diffused Lamps
Figure 13. Relative Luminous
Intensity vs. Forward Current.
Figure 12. Forward Current vs.
Forward Voltage Characteristics. Figure 14. Relative Efficiency
(Luminous Intensity per Unit Current)
vs. Peak LED Current.
Figure 15. Maximum Tolerable Peak
Current vs. Pulse Duration. (IDC MAX
as per MAX Ratings).
Figure 16. Relative Luminous Intensity vs. Angular Displacement.