SPECIFICATION CONTROL DRAWING TITLE 44AM112X Date TWO CONDUCTOR CABLE, SHIELDED, JACKETED, GENERAL PURPOSE, 600 VOLT Revision D 11-21-05 This specification sheet forms a part of the latest issue of Raychem Specification 44 and MIL-DTL-27500 as applicable. COMPONENT WIRES - 44A011X SHIELD - COPPER, COATED AS ON CONDUCTOR EXCEPT TIN COATED SHIELD WITH SILVER COATED HIGH STRENGTH ALLOY CONDUCTOR JACKET - RADIATION-CROSSLINKED, MODIFIED PVF2 TABLE I. CABLE CONSTRUCTION DETAILS PART NUMBER 1/ CONDUCTOR SIZE (AWG) SHIELD SIZE (AWG) 44AM112X-26-* 44AM112X-24-* 44AM112X-22-* 44AM112X-20-* 44AM112X-18-* 44AM112X-16-* 44AM112X-14-* 44AM112X-12-* 26 24 22 20 18 16 14 12 38 38 38 38 38 38 38 38 JACKET THICKNESS (in.) MINIMUM .005 .005 .005 .005 .005 .006 .006 .007 MAXIMUM .010 .010 .010 .010 .010 .012 .012 .014 OUTSIDE DIAMETER (in.) NOMINAL .101 .113 .127 .143 .163 .179 .213 .251 MAXIMUM WEIGHT (lbs/1000 ft.) MAXIMUM .108 .120 .134 .150 .171 .187 .222 .262 8.2 10.4 13.3 17.2 23.3 28.5 40.8 58.9 TABLE II. CABLE PERFORMANCE DETAILS BEND TESTING MANDREL DIAMETER (inch) ( 3%) PART NUMBER 1/ 44AM112X-26-* 44AM112X-24-* 44AM112X-22-* 44AM112X-20-* 44AM112X-18-* 44AM112X-16-* 44AM112X-14-* 44AM112X-12-* IMMERSION AND CROSSLINKED VERIFICATION 3.00 3.00 6.00 6.00 6.00 6.00 6.00 10.00 COLD BEND 3.00 3.00 6.00 6.00 6.00 6.00 6.00 10.00 WEIGHT (lb) ( 3%) IMMERSION AND CROSSLINKED VERIFICATION .250 .375 .375 .375 .500 .500 1.00 1.00 COLD BEND 1.50 1.50 3.00 3.00 3.00 3.00 9.00 9.00 NOTE: Nominal values are for information only. Nominal values are not requirements. Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER, AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: "901/902..." MAY BE REPLACED BY "Axxx".) OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL. Page 1 of 2 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. R Wire & Cable 501 Oakside Avenue Redwood City, CA 94063-3800 Phone: 1-800-227-8816 Fax: 1-650-361-6297 (c) 2005 Tyco Electronics Corporation. All rights reserved. Revision SPECIFICATION CONTROL DRAWING Page 2 of 2 D SCD Number 44AM112X CABLE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 150C Maximum continuous conductor temperature VOLTAGE RATING: 600 volts (rms) at sea level BLOCKING: 150 3C for 6 hours CROSSLINKED VERIFICATION: 200 5C for 6 hours DIELECTRIC WITHSTAND: 1500 volts (rms), 60 Hz, 15 seconds (minimum), 30 seconds (maximum) FLAMMABILITY: 30 seconds (maximum); 3 in. (maximum); no flaming of facial tissue IMMERSION: Diameter increase 5% (maximum); no cracking, no dielectric breakdown JACKET COLOR: White preferred JACKET CONCENTRICITY: 70% (minimum) JACKET ELONGATION AND TENSILE STRENGTH: Elongation, 200% (minimum) Tensile Strength, 4000 lbf/in (minimum) JACKET FLAWS: Spark Test, 1.5 kV (rms) Impulse Dielectric Test, 6.0 kV (peak) LOW TEMPERATURE-COLD BEND: -55 5C for 4 hours SHIELD COVERAGE: 85% (minimum) VOLTAGE WITHSTAND TEST (POST ENVIRONMENTAL): 1000 volts (rms), 60 Hz, 1 minute PART NUMBER: The "X" in the part numbers on page 1 shall be replaced by the applicable conductor material designators as follow: 1 tin coated copper 2 silver coated copper 3 nickel coated copper 4 silver coated high strength copper alloy (AWG's 26-16 only) 6 nickel coated high strength copper alloy (AWG's 26-20 only) The "*" in the part numbers on page 1 shall be replaced by color code designators with a slash separating the component wire colors and a dash separating the component wire colors from the jacket color. 1/ Example: AWG 24, tin-coated copper, black and brown component wires; white jacket: 44AM1121-24-0/1-9 1/ See footer section on page 1.