General Purpose Relays SCHRACK
1
Power Relay RM 8
n2 pole 25 A, 2 CO contacts
nDC- or AC-coil
nMechanical indicator
nPush-to-test button
nChassis- or DIN-rail mount
Applications
Cleaning equipment, heating and cooling equipment
F0165-B
Approvals
VREG.-Nr. 40003144, ZE214025
Technical data of approved types on request
Contact data RM8
Contact configuration 2 CO contacts
Contact set single contact
Type of interruption micro disconnection
Rated voltage / max. switching voltage AC 400 VAC
Rated current 25 A
Maximum breaking capacity AC 6000 VA
Limiting making capacity, max 20 ms 60 A
Contact material AgCdO
Rated frequency of operation with / without load 16/100 min-1
Operate- / release time DC coil max 15/10 ms
Bounce time DC coil NO / NC contact max 4/6 ms
Contact ratings
Type Contact Load Ambient Cycles
temp. [°C]
IEC 61810
RM80 CO 25 A, 250 VAC, cosϕ=1 35°C 10x103
UL 508
RM80 NO / NC 25 A, 240 VAC, 1 phase per pole, general purpose 40°C 6x103
RM80 NO / NC 25 A, 415 VAC, resisitive 50°C 10x103
Coil data
Rated coil voltage range DC coil 6...220 VDC
AC coil 6...400 VAC
Operative range to IEC 61810 2
Coil versions, DC-coil
Coil code Rated Operate Release Coil Rated coil
STD LED PD* LED+ voltage voltage voltage resistance power
bipolar PD* VDC VDC VDC Ohm W
006 L06 0A6 LA6 6 4.5 0.6 32+10% 1.1
012 L12 0B2 LB2 12 9.0 1.2 110+10% 1.3
024 L24 0C4 LC4 24 18.0 2.4 475+10% 1.2
048 L48 0E8 LE8 48 36.0 4.8 2000+10% 1.2
060 L60 0G0 LG0 60 45.0 6.0 2850+10% 1.3
110 M10 1B0 MB0 110 82.5 11.0 10000+12% 1.2
221 N21 2C1 NC1 220 165.0 22.0 40000+15% 1.2
All figures are given for coil without preenergization, at ambient temperature +23°C
*) Protection diode PD; standard polarity: +A1 / -A2