DC/DC Converter
www.recom-power.com REV.: 4/2019 PB-1
E224736
RPA100H-RUW
Description
The half-brick RPA100H series DC/DC converter is designed for railway rolling stock and high voltage
battery applications. It has a 10:1 input voltage range to cover all input voltages from nominal 24VDC
up to 110VDC in a single product (including EN50155 transients) and offers isolated and regulated
12V, 15V, 24V or 48VDC outputs. The converter has a consistently high efficiency over the entire
input voltage range and comes with a metal baseplate to permit a wide operating temperature range
from -40°C to +97°C (when baseplate cooled). The case is fitted with threaded inserts to allow
secure mounting to the PCB or bulkhead for use in high shock and vibration environments.
The converter is certified to UL/IEC/EN60950 and comes with a three year warranty.
Features
Regulated
Converter
10:1 ultra wide input voltage range
4.242kVDC/1 minute reinforced insulation
UL/IEC/EN60950-1 certified
CE marked, CB report
Efficiency up to 93%
-40°C to +100°C baseplate temperature range
100 Watt
Half Brick
Single Output
Selection Guide
Part Number Input Output Output Efficiency Max. Capacitive
Voltage Range (1) Voltage Current typ.
(2) Load
(3)
[VDC] [VDC] [A] [%] [µF]
RPA100H-11012SRUW(4) 16.5-140 12 8.5 90 2200
RPA100H-11015SRUW(4) 16.5-140 15 6.7 93 2200
RPA100H-11024SRUW(4) 16.5-140 24 4.2 88 1000
RPA100H-11048SRUW(4) 16.5-140 48 2.1 90 100
Ordering Examples
RPA100H-11012SRUW/P = 110V Input, 12V Output, Single, Pos. CTRL function
RPA100H-11012SRUW/N = 110V Input, 12V Output, Single, Neg. CTRL function
Model Numbering
Input Voltage
Output Voltage
Single
RPA100H-__ __ SRUW/_
Notes:
Note4: add suffix “P” for positive logic (1=ON, 0=OFF) or add
suffix “N” instead for negative logic (0=ON, 1=OFF)
BASIC CHARACTERISTICS
Parameter Condition Min. Typ. Max.
Internal Input Filter Pi-Type
Input Voltage Range 16.5VDC 110VDC 140VDC
Input Surge Voltage <1s 156VDC
Under Voltage Lockout (UVLO) (5) DC-DC ON
DC-DC OFF
15.6VDC
13.6VDC
16.0VDC
14.0VDC
16.4VDC
14.4VDC
Over Voltage Lockout (OVLO) DC-DC ON
DC-DC OFF
142VDC
154VDC
146VDC
156VDC
150VDC
160VDC
Input Current Range Vin = 16.5VDC 7A 7.2A 7.5A
continued on next page
Specifications (measured @ Ta = 25°C, nom. Vin (110V), full load and after warm-up unless otherwise stated)
CTRL Logic (4)
Railway Ultra Wide Input
Notes:
Note1: Refer to “Input Voltage Range”
Note2: Efficiency is tested at nominal input (110V) and full load at +25°C ambient
Note3: Max. Cap Load is tested at nominal input and full resistive load
UL60950-1 certified
CAN/CSA No. 60950-1-07 certified
IEC/EN60950-1 certified
EN50155 compliant
CB report
Notes:
Note5: Refer to “UNDER VOLTAGE LOCKOUT ADJUSTABILITY” for detail information
https://www.recom-power.com/pdf/
Powerline_DC-DC/RSPxxx-168.pdf
www.recom-power.com REV.: 4/2019 PB-2
DC/DC Converter
Specifications (measured @ Ta = 25°C, nom. Vin (110V), full load and after warm-up unless otherwise stated)
RPA100H-RUW
Series
BASIC CHARACTERISTICS
Parameter Condition Min. Typ. Max.
Quiescent Current Vin = 110VDC 12, 15, 24Vout
48Vout
30mA
50mA
60mA
80mA
90mA
150mA
Output Voltage Trimming refer to “OUTPUT VOLTAGE TRIMMING” -20% +10%
Minimum Load 0%
Start-up Time 200ms 460ms
Rise Time Vout from 10% to 90% 50ms 100ms
ON/OFF Control (6)
Positive Logic DC-DC ON
DC-DC OFF
Open or 3 < Vr < 5VDC
Short or 0 < Vr < 0.4VDC
Negative Logic DC-DC ON
DC-DC OFF
Short or 0 < Vr < 0.4VDC
Open or 3 < Vr < 5VDC
Input Current of CTRL pin DC-DC ON
DC-DC OFF
0.1mA
0.1mA
0.2mA
0.1mA
Standby Current 20mA
Internal Operating Frequency 140kHz
Output Ripple & Noise 20MHz BW limited 250mVp-p
Remote Sense (6) ±10%
continued on next page
Efficiency vs. Output Current
Efficiency vs. Output Current
RPA100H-11012SRUW
RPA100H-11015SRUW
16.5V
24V
36V
48V
72V
110V
140V
Efficiency [%]
Output Current [%]
00
10
10
20
20
30
30
40
40
50
50
60
60
70
70
80
80
90
90
100
100
Dissipated Power [W]
Output Current [A]
0
0
2
2 3
4
4 5
6
6 7
8
8 8.5
10
12
14
16
18
20
1
16.5V
24V
36V
48V
72V
110V
140V
Dissipated Power [W]
Output Current [A]
0
0
4
2
6
10
8
12
14
16
42 6 6.7
16.5V
24V
36V
48V
72V
110V
140V
16.5V
24V
36V
48V
72V
110V
140V
Efficiency [%]
Output Current [%]
00
10
10
20
20
30
30
40
40
50
50
60
60
70
70
80
80
90
90
100
100
Notes:
Note6: For detail information refer to “ON/OFF CONTROL” or “REMOTE SENSE”
Power Dissipation vs. Output Current
Power Dissipation vs. Output Current
www.recom-power.com REV.: 4/2019 PB-3
DC/DC Converter
Specifications (measured @ Ta = 25°C, nom. Vin (110V), full load and after warm-up unless otherwise stated)
RPA100H-RUW
Series
UNDER VOLTAGE LOCKOUT ADJUSTABILITY
RPA100H-11024SRUW
RPA100H-11048SRUW
Efficiency vs. Output Current
Efficiency vs. Output Current
Power Dissipation vs. Output Current
Power Dissipation vs. Output Current
16.5V
24V
36V
48V
72V
110V
140V
Efficiency [%]
Output Current [%]
00
10
10
20
20
30
30
40
40
50
50
60
60
70
70
80
80
90
90
100
100
Dissipated Power [W]
Output Current [A]
0
0
10
8
6
4
2
20
18
16
14
12
4 4.22 31
16.5V
24V
36V
48V
72V
110V
140V
16.5V
72V
110V
140V
Efficiency [%]
Output Current [%]
00
10
10
20
20
30
30
40
40
50
50
60
60
70
70
80
80
90
90
100
100
Dissipated Power [W]
Output Current [A]
0 2 2.11 1.50.5
0
2
10
12
14
16
18
6
4
20
8
16.5V
24V
36V
48V
72V
110V
140V
Input Voltage [VDC]
Output Power [%]
100
0
0.1s continuous operation 1s
14.4 16.5 140 156
CTRL
Q1
R1
R1
ext. Cap
Hold Up Circuit
D1
C1
C1
C2
+Vin
+Vin
+Vout
-Vout
+Vout
-Vout
+Vout
-Vout
UVLO
-Vin
-Vin
-Vin
R1
Input Voltage Range
The RPA100H series has an adjustable under voltage lockout which will shut down the
converter according to following settings.
Continuous full power operation is rated between 16.5V and 140V,
including full load start-up.
Once running, the converter will operate for short periods of time over
an extended input voltage range down to 14.4V and up to 156V, thus
covering all EN50155 under-voltage and over-voltage transient
conditions.
Nom. Input Voltage [VDC] 24 36 48 72 110
Turn Off Threshold [VDC] 14±0.4V 20.6±1V 27.5±1V 40±1V 64±2V
Turn On Threshold [VDC] 16±0.4V 24±1V 32±1V 46.5±1V 74±2V
Resistor R1 [k] open 24.9 12.4 6.19 3.48
www.recom-power.com REV.: 4/2019 PB-4
DC/DC Converter
Specifications (measured @ Ta = 25°C, nom. Vin (110V), full load and after warm-up unless otherwise stated)
RPA100H-RUW
Series
OUTPUT VOLTAGE TRIMMING
continued on next page
TRIM UP TRIM DOWN
Rup
Trim
+Sense
-Sense
Trim
Rdown
Output Voltage Trimming
RPA100H-RUW converters offer the feature of trimming the output voltage over a certain range around the nominal value by using external trim resistors.
The values for trim resistors shown in trim tables below are according to standard E96 values; therefore, the specified voltage may slightly vary; they also
can be calculated with below shown equation.
Practical Example RPA100H-12SRUW trim up +10% Practical Example RPA100H-12SRUW trim down -8%
Calculation:
Rdown =Vref - R1
DVout
Rup =R2 - R3
DVout
Rup according to E96 487kRdown according to E96 53k6
Voutnom = nominal output voltage [VDC]
DVout = output voltage change [%]
Vref = reference voltage [VDC]
Rup = trim up resistor []
Rdown = trim down resistor []
R1 - R3 = internal resistors []
Voutnom R1R2R3Vref
12VDC
10k2
45k40k
5.11VDC
15VDC 57k452k3
24VDC 95k90k
48VDC 195k190k
Rup =45k + 40k = 490k
0.1 Rdown =5.11 - 10k2 = 53k6
0.08
RPA100H-11015SRUW
RPA100H-11048SRUW
RPA100H-11012SRUW
RPA100H-11024SRUW
Trim up 1 2 3 4 5 6 7 8 9 10 [%]
Voutset = 15.15 15.30 15.45 15.60 15.75 15.90 16.05 16.20 16.35 16.50 [VDC]
Rup (E96) 5M76 2M94 1M96 1M50 1M21 1M01 866k 768k 681k 619k []
Trim up 1 2 3 4 5 6 7 8 9 10 [%]
Voutset = 48.48 48.96 49.44 49.92 50.40 50.88 51.36 51.84 52.32 52.80 [VDC]
Rup (E96) 19M60 9M88 6M65 5M11 4M12 3M48 3M10 2M61 2M37 2M15 []
Trim up 1 2 3 4 5 6 7 8 9 10 [%]
Voutset = 12.12 12.24 12.36 12.48 12.60 12.72 12.84 12.96 13.08 13.20 [VDC]
Rup (E96) 4M53 2M32 1M54 1M15 931k 787k 681k 604 536k 487k []
Trim up 1 2 3 4 5 6 7 8 9 10 [%]
Voutset = 24.24 24.48 24.72 24.96 25.20 25.44 25.68 25.92 26.16 26.40 [VDC]
Rup (E96) 9M53 4M87 3M24 2M49 2M 1M69 1M43 1M27 1M15 1M50 []
www.recom-power.com REV.: 4/2019 PB-5
DC/DC Converter
Specifications (measured @ Ta = 25°C, nom. Vin (110V), full load and after warm-up unless otherwise stated)
RPA100H-RUW
Series
REGULATION
Parameter Condition Value
Output Accuracy ±1.0% max.
Line Regulation Vin = 16.5VDC to 140VDC, Io = full load ±0.01% typ. to ±0.2% max.
Load Regulation 10 - 90% load 0.05% typ. to 0.2% max.
Transient Response 25% load step change
12Vout 450mV/40µs typ.
15Vout 450mV/30µs typ.
24Vout 500mV/20µs typ.
48Vout 600mV/10µs typ.
EXTERNAL CAPACITOR
ON/OFF CONTROL
REMOTE SENSE
CTRL
Q1
R1
R1
ext. Cap
Hold Up Circuit
D1
C1
C1
C2
+Vin
+Vin
+Vout
-Vout
+Vout
-Vout
+Vout
-Vout
UVLO
-Vin
-Vin
-Vin
R1
C1 24Vin 36Vin 48Vin 72Vin 96Vin 110Vin
For 10ms 1600µF 1600µF 1600µF 1600µF 820µF 560µF
For 30ms 4800µF 4800µF 4800µF 4800µF 2460µF 1680µF
A 240µF/200V capacitor (C2) is required for normal operation.
To meet power supply interruptions, an external circuit comprised of a capacitor (C1),
a 100Ω/1W resistor (R1) and a 200V/3A diode (D1) is required.
+Vout
+Vin
-Vin -Vout
(GND)
+Sense
RW2
RW2
R1
R2
-Sense
Trim
Load
RW1 ... wire losses +
RW2 ... wire losses -
R1 ... trim up resistor
R2 ... trim down resistor
The output voltage can be adjusted by both trim and remote sense. The
maximum combined adjustment range is ±10%. Derate the maximum
output power if using the trim or sense function to increase the output
voltage.
CTRL
Q1
R1
R1
ext. Cap
Hold Up Circuit
D1
C1
C1
C2
+Vin
+Vin
+Vout
-Vout
+Vout
-Vout
+Vout
-Vout
UVLO
-Vin
-Vin
-Vin
R1
For negative logic, if the remote on/off feature is not used, short the on/off pin to -Vin.
For positive logic, if the remote on/off feature is not used, leave the on/off pin floating.
Trim down RPA100H series
Trim down 1 2 3 4 5 6 7 8 9 10 [%]
Rdown (E96) 499k 243k 162k 118k 90k9 75k 63k4 53k6 46k4 41k2 []
Trim down 11 12 13 14 15 16 17 18 19 20 [%]
Rdown (E96) 36k5 32k4 28k7 26k1 23k7 22k1 20k 18k2 16k5 15k4 []
www.recom-power.com REV.: 4/2019 PB-6
DC/DC Converter
Specifications (measured @ Ta = 25°C, nom. Vin (110V), full load and after warm-up unless otherwise stated)
RPA100H-RUW
Series
PROTECTION
Parameter Condition Value
Over Voltage Protection (OVP) 110-130%, automatic recovery
Over Current Protection (OCP) hiccup mode, automatic recovery
Over Temperature Protection (OTP) @ tc point +105°C, automatic recovery after cooling down
Isolation Voltage (7) I/P to O/P,
O/P to baseplate rated for 1 minute 4.242kVDC
4.242kVDC
Isolation Resistance 10M typ.
Isolation Capacitance 500pF
Leakage Current 0.42mA
Insulation Grade reinforced
Notes:
Note7: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note8: Refer to local safety regulations if input over-current protection is also required. Recommended fuse T20A slow blow type
RPA100H-11048SRUW
Accuracy vs. Load
Normalized Accuracy [%]
Output Current [A]
0
0
2
1
-1
0.8
0.2
-0.2
0.4
-0.4
-0.6
-0.8
0.6
4 6 8 8.5
72V
110V
140V
16.5V
24V
36V
48V
Normalized Accuracy [%]
Output Current [A]
0 2 4 6 6.7
0
1
-1
0.8
0.2
-0.2
0.4
-0.4
-0.6
-0.8
0.6
72V
110V
140V
16.5V
24V
36V
48V
Normalized Accuracy [%]
Output Current [A]
0 21 3 4 4.2
0
1
-1
0.8
0.2
-0.2
0.4
-0.4
-0.6
-0.8
0.6
72V
110V
140V
16.5V
24V
36V
48V
Normalized Accuracy [%]
Output Current [A]
0 10.5 1.5 2 2.1
0
1
-1
0.8
0.2
-0.2
0.4
-0.4
-0.6
-0.8
0.6
72V
110V
140V
16.5V
24V
36V
48V
RPA100H-11024SRUW
RPA100H-11015SRUWRPA100H-11012SRUW
www.recom-power.com REV.: 4/2019 PB-7
DC/DC Converter
Specifications (measured @ Ta = 25°C, nom. Vin (110V), full load and after warm-up unless otherwise stated)
RPA100H-RUW
Series
ENVIRONMENTAL
Parameter Condition
Value
Operating Temperature Range refer to derating graphs
Maximum Baseplate Temperature measured @ tc point +100°C
Temperature Coefficient 0.007%/°C
Thermal Impedance refer to Rth tables
Operating Altitude 5000m
Operating Humidity 5%-95% RH
Pollution Degree (PD) PD2
Fire protection on Railway Vehicles refer to page 9 according to EN45545-2 standard
MTBF according to Telcordia SR332 Issue 2 Method I, 25°C 1480 x 103 hours
continued on next page
-40 -20 0
0
20
20
40
40
50
60
74
60
80
80
100
100
120
120
Output Power [%]
Ambient Temperature [°C]
without PCB, fitted Heat-sink:
Natural Convection (0.1m/s)
with PCB and Heat-sink:
Natural Convection (0.1m/s)
0.2m/s
0.5m/s
0.8m/s
1.0m/s
1.5m/s
63.1
20.0
6.4
3.2
3.5
3.4 +0.0/-0.3
60.6
48.3
50.8
Ø
Ø
Thermal Impedance
airflow
[m/s]
Rth
[°C/W]
0.1 3.3
0.2 2.62
0.5 2.0
0.8 1.57
1.0 1.22
1.5 0.75
Iout = 50%
Rth = 3.3°C/W
PDISS = 7.87W
TICmax = 100°C
Thermal Calculation Example
TAMBmax = TICmax - TOVER = 100°C - 26°C = +74°C
TOVER = Rth x PDiss = 3.3°C/W x 7.87W = +26°C
Notes:
Note9: Following calculations are made with RPA100H-11012SRUW/P.
Test PCB: Eurocard 160x100mm 105µm copper, double layer
Thermal Derating with Fan Cooling, Double Layer PCB and Heat-sink
Dimension Drawing Heat-sink (mm)
www.recom-power.com REV.: 4/2019 PB-8
DC/DC Converter
Specifications (measured @ Ta = 25°C, nom. Vin (110V), full load and after warm-up unless otherwise stated)
RPA100H-RUW
Series
-40 -20 0
0
20
20
40
40
60
60
50
80
80
100
100
120
120
Output Power [%]
Ambient Temperature [°C]
Natural Convection (0.1m/s w/o PCB)
with PCB:
Natural Convection (0.1m/s)
0.2m/s
0.5m/s
0.8m/s
1.0m/s
1.5m/s
-40 -20 0
0
20
20
40
40
60
60
80
97
80
100
100
120
120
Output Power [%]
Ambient Temperature [°C]
2.3l/min
Thermal Impedance
airflow
[m/s]
Rth
[°C/W]
0.1 3.8
0.2 3.12
0.5 2.5
0.8 2.07
1.0 1.72
1.5 1.25
Thermal Impedance
liquid flow
[l/min]
Rth
[°C/W]
2.3 0.31
Iout = 50%
Rth = 2.5°C/W
PDISS = 7.87W
TICmax = 100°C
Iout = 100%
Rth = 0.31°C/W
PDISS = 10.94W
TICmax = 100°C
Thermal Calculation Example
Thermal Calculation Example
TAMBmax = TICmax - TOVER = 100°C -20°C = +80°C
TAMBmax = TICmax - TOVER = 100°C - 3.4°C = +97°C
TOVER = Rth x PDiss = 2.5°C/W x 7.87W = +20°C
TOVER = Rth x PDiss = 0.31°C/W x 10.94W = +3.4°C
Notes:
Note10: For further details please contact our Tech Support Team techsupportAT@recom-power.com
Thermal Derating with Fan Cooling and Double Layer PCB
Thermal Derating with Water Cooling
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
Information Technology Equipment, General Requirements for Safety E224736-A54-UL and
E224736-A57-UL
UL60950-1, 2nd Edition: 2014
CAN/CSA-C22.2 No. 60950-1-07, 2nd Edition: 2014
IEC/EN Information Technology Equipment - General Requirments for
Safety (CB Scheme) E224736-A54-CB-1 and
E224736-A57-CB-1
IEC60950-1: 2005, 2nd Edition + AM2: 2013
IEC/EN Information Technology Equipment - General Requirments for
Safety EN60950-1: 2006 + A2: 2013
continued on next page
www.recom-power.com REV.: 4/2019 PB-9
DC/DC Converter
Specifications (measured @ Ta = 25°C, nom. Vin (110V), full load and after warm-up unless otherwise stated)
RPA100H-RUW
Series
Fire hazard testing - Part 11-10: Test flames - 50W horizontal and vertical
flame test methods Vertical Flame Test
EN60695-11-10: 2013, HL1, HL2, HL3, V-0
Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods;
Glow-wire flammability test method for end-products
Glow-Wire Flammability Test
30s ta, 850°C EN60695-2-11:2000, HL1, HL2, HL3
Plastics - Determination of burning behaviour by oxygen index -
Part 2: Ambient-temperature test
OI% (min) 42.6%
OI% (min) 36.8%
EN ISO 4589-2:2006, HL1, HL2, HL3
EN ISO 4589-2:1999 + A1:2006, HL1, HL2, HL3
Railway Applications - Electrical Equipment used on rolling stock EN50155:2007
Railway applications - Fire protection on railway vehicles
Part 2: Requirements for fire behaviour of materials and components EN45545-2:2013 + A1:2015
EAC RU-AT.49.09571 TP TC 004/2011
RoHS2 RoHS 2011/65/EU + AM2015/863
EMC Compliance Condition Standard / Criterion
Railway applications - Electromagnetic compatibility -
Part 3-2: Rolling stock - Apparatus with external components EN50121-3-2:2015
ESD Electrostatic discharge immunity test Air ±8kV, Contact ±6kV EN61000-4-2, Criteria B
Radiated, radio-frequency, electromagnetic field immunity test
80-1000MHz, 20V/m
800-1000MHz, 20V/m
1400-2100MHz, 10V/m
2100-2500MHz, 5V/m
EN61000-4-3, Criteria A
Fast Transient and Burst Immunity ±2kV EN61000-4-4, Criteria A
Surge Immunity ±1kV (diff), ±2kV (com) EN61000-4-5, Criteria B
Immunity to conducted disturbances, induced by radio-frequency fields 10V EN61000-4-6, Criteria A
Electromagnetic compatibility of multimedia equipment - Emission
requirements with external components EN55032, Class B
continued on next page
EMC Filtering according to EN50121-3-2
Fuse
C2
C1 C6 C7 C8
C10
C9
4
5 6
7
8
9
10
3
2
1
C3
MOV
C4
C5
+VIN
-VIN
LOAD
MOV C1 C2, C3, C4, C5 L1 C6, C7 C8 C9, C10
EPCOS
B72207S0131K101
100nF
275VAC 1000pF, 300VAC 1mH
CMC
0.47µF
250V
100µF
200V
120µF
200V
www.recom-power.com REV.: 4/2019 PB-10
DC/DC Converter
Specifications (measured @ Ta = 25°C, nom. Vin (110V), full load and after warm-up unless otherwise stated)
RPA100H-RUW
Series
DIMENSIONS and PHYSICAL CHARACTERISTICS
Parameter Type Value
Material
baseplate
case
potting
aluminum
plastic (UL94V-2)
low smoke silicone (UL94V-0)
Package Dimensions (LxWxH) 60.6 x 63.1 x 13.0mm
Package Weight 125.0g typ.
continued on next page
C1 C4 C11 C12
C13 C14
4
5 6
7
8
9
10
3
2
1
C2
C3
+V
IN
-V
IN
LOAD
L1
EN55022
C5 C7
C8 C10
C9
C6
L2
C15
C16
C19
C20
C17
C18
C21
C22
Fuse
C2
C1 C6 C7 C8
C10
C9
4
5 6
7
8
9
10
3
2
1
C3
MOV
C4
C5
+VIN
-VIN
LOAD
L1
EN50155
EMC Filtering according to EN55032 Class B
C1, C4, C11 L1, L2 C2, C3, C5, C6,
C7, C8, C9, C10 C12 C13
C14
C15, C16, C17
C18, C19, C20
0.47µF, 250V
MLCC
1mH
CMC 1.5nF, 3kV 100µF
200V
120µF
200V 6.8nF, 2kV
www.recom-power.com REV.: 4/2019 PB-11
DC/DC Converter
Specifications (measured @ Ta = 25°C, nom. Vin (110V), full load and after warm-up unless otherwise stated)
RPA100H-RUW
Series
Dimension Drawing (mm)
60.60
63.1
1
6
7
8
9
10
2
3
4
5
4.30
35.56
7.62 10.16
17.78
25.40
13.0
48.30
Bottom View
5
4
3
2
1
6
7
8
9
10
Top View
FC 50.80
M3
1.0
+0.15/-0.05
Ø
2.0
+0.15/-0.05
Ø
2.54
2.54
FC 48.30
30.3
31.5
tc
Pin Connections
Pin # Single
1 +Vin
2 UVLO
3 CTRL
4 Ext. Cap.
5 -Vin
6 -Vout
7 -Sense
8 Trim
9 +Sense
10 +Vout
XX.X ± 0.5mm
XX.XX ± 0.25mm
FC= fixing center
Recommended Footprint Details
Pin1 identification
9
RECOM Power GmbH
Münzfeld 35
4810 Gmunden, AUSTRIA
www.recom-power.com
CRTL
UVLO
-Vout
-Sense
Trim
+Sense
+Vout
R1
Ext. Cap.
-Vin
Hold Up Circuit
D1
C1
240µF
200V
Connect Sense to Vout if not used
-Vin
Ext.
Cap
+Vin
(Pin1)
+Vout
-Vout
(GND)
+Sense
R1
R2
-Sense
Trim
Load
I/P: 16.8-137.5V , 7.5A
O/P: 24V , 4.2A
RPA100H-11024SRUW/P
XXXX
EXXXXXX
R
DT
Pin1
Pin1
www.recom-power.com REV.: 4/2019 PB-12
DC/DC Converter
Specifications (measured @ Ta = 25°C, nom. Vin (110V), full load and after warm-up unless otherwise stated)
RPA100H-RUW
Series
BLOCK DIAGRAMM
The
product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer.
The
products
are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or
cause
loss
of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the
unauthorized
use of RECOM products in such safety-critical applications.
PACKAGING INFORMATION
Parameter Type Value
Packaging Dimensions (LxWxH) tube 355.0 x 63.5 x 20.6mm
Packaging Quantity 5pcs
Storage Temperature Range -55°C to +125°C
Storage Humidity 95% RH
Input Filter
PWM Controller
PWM
Controller
Feedback
and Isolation
+Vin
-Vin
CTRL
+Vout
-Vout
+Sense
-Sense
Trim
Rectifier and
Output Filter
TransformerBoost
Half
Bridge
µ Controller
UVLO
ext.
Cap