Ti125, Ti110, Ti105 Industrial-Commercial and the Ti100 General Use Thermal Imagers Technical Data The lightest, most rugged and easiest-to-use professional thermal imagers around. A Fluke thermal imager can save you time and money by finding potential problems before they become costly failures. With the innovative features and functionality in the Fluke Ti125, Ti110, Ti105 and Ti100 imagers, you can perform infrared inspections faster and more efficiently and thoroughly document problem areas for additional follow-up. Ti125 Ti100 Made in the U.S.A. of U.S. and non U.S. parts Ti110 TM Fluke CNXTM enabled Industrial, mechanical, electromechanical and general building maintenance. Process, refractory insulation, tank and vessel levels, steam systems and traps, pipes and valves, etc. Electrical, unbalanced loads, overloaded systems, wiring problems or component failure, etc. Ti105 Key features * Exclusive IR-OptiFlexTM focus system--ensures that images are in good focus from 1.2 meters (4 feet) and beyond for optimum image clarity and scanning convenience. For shorter distances change to manual mode with the touch of a finger (Ti110 and Ti125). * Always have references handy--IR-PhotoNotesTM annotation system--Quickly identify and keep track of inspection locations by adding digital images of important information and surrounding areas (Ti110 and Ti125). * Find problems faster and easier with Fluke IR-Fusion(R) technology (Ti125, Ti110, Ti105). Accurately identify potential issues by combining digital and IR images. * Capture additional measurements fast and conveniently from up to five wireless modules at once using your Fluke thermal imager and CNXTM wireless modules. * Get further clarification with AutoBlendTM mode--the blending of a digital and partially transparent IR image into a single information-filled image (Ti125 only). * Multi-mode video recording--focus-free video in visible light and infrared with full IR-Fusion. (Ti110 and Ti125 only). * Easily communicate the location of problems with the Electronic 8-Point Cardinal Compass (Ti110 and Ti125 only). Spend less time finding problems and more time solving them with the innovative, rugged and easy to use Ti125, Ti110, Ti105 Industrial-Commercial and Ti100 General Use Thermal Imagers. Patented Fluke IR-Fusion(R) Technology Enjoy the industry's only point-and-shoot IR-Fusion camera. Fluke patented technology provides the user with both a digital and an infrared image in one to precisely document problem areas. IR-OptiFlexTM focus system Scan for issues significantly faster than before with Fluke's revolutionary, ultra-rugged focus system. The IR-OptiFlex focus system gives you optimum focus by combining focus-free, ease-of-use with the flexibility of manual focus on the same camera. Detailed specifications Ti125 Ti110 Ti105 Ti100 Industrial-Commercial IR resolution (FPA size) General use 160 x 120 FPA Uncooled Microbolometer Spectral band 7.5 m to 14 m (long wave) Capture or refresh rate 9 Hz or 30 Hz versions NETD (Thermal sensitivity) 9 Hz 0.10 C at 30 C target temp (100 mK) FOV (Field of view) 22.5 H x 31 V IFOV (Spatial resolution) Temperature measurement range (not calibrated below -10 C) 3.39 mRad -20 C to +350 C (-4 F to +662 F) -20 C to +250 C (-4 F to +482 F) Temperature measurement accuracy 2 C or 2 % (at 25 C nominal, whichever is greater) Focus mechanism IR-OptiFlexTM focus system PIP, FULL IR, FULL VISIBLE, AutoBlendTM IR-Fusion(R) technology Focus-free 1.2 m (4 ft) and beyond CNXTM Wireless enabled Standard palettes Ultra ContrastTM palettes Hot/cold markers High temperature -- Blue-Red, Grayscale, Inverted Grayscale, High-contrast, Hot Metal, Ironbow, Amber, Inverted Amber Blue-Red, Ironbow, Grayscale, Amber Blue-Red, Grayscale, Inverted Grayscale, High-contrast, Blue-Red, Grayscale, Ironbow Hot Metal, Ironbow, Amber, Inverted Amber -- Yes User definable spot markers -- in SmartView(R) only Three on camera and in SmartView(R) Centerpoint Yes Centerbox (MIN/AVG/MAX) Yes -- Level and span control Manual and auto Minimum span in auto mode 5 C Minimum span in manual mode 2.5 C Minimum IR focus distance 15.25 cm (6 in) 122 cm (48 in) Weight 0.726 kg (1.6 lb) Size 28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in) LCD display 3.5 inch diagonal (portrait format) Visible camera 2 megapixel industrial-grade Minimum parallax ~45.7 - 55.9 cm (~ 18 in - 22 in) IR-PhotoNotesTM annotation system N/A ~122 cm (48 in) Yes (3 images) N/A -- Laser pointer Yes Torch Yes Electronic (cardinal) compass -- Yes -- Emissivity correction Yes Transmission correction Yes -- Background (reflected) compensation Yes Voice annotation (audio) Multi-mode video output Multi-mode video recording (standard avi w/ mpeg encoding) Multi-mode video recording (radiometric .is3) Yes (60 seconds) per image -- Streaming USB video output (infrared, visible and IR-Fusion modes) -- Yes (AVI with MPEG encoding, up to 5 minutes) -- Yes, radiometric .is3 for approx. 2.5 to 5 minutes depending upon thermal scene Memory review -- thumbnail review Battery (field-replaceable, rechargeable) Two Battery life One 4+ hours (each)* External battery charging base Charging power supply Yes Optional (accessory) Yes *Assumes 50 % brightness of LCD 2 Fluke Corporation No, full IR only Yes High temperature, low temperature, isotherm Color alarms PIP (1.2 m (4 ft) to 4.6 m (15 ft)), FULL IR, FULL VISIBLE PIP, FULL IR, FULL VISIBLE Ti125, Ti110, Ti105 Industrial/Electrical and Ti100 General Use Thermal Imagers Ti125 Ti110 Ti105 Industrial-Commercial Drop test Ti100 General use 2 meter (6.5 feet) Ingress protection (IP) rating (IEC 60529) IP 54 Recommended Calibration cycle Multifunction card reader Two-years Included -- Memory storage 2 GB SD memory card Direct download capability mini USB download direct to PC Operating temperature range -10 C to +50 C (14 F to 122 F) Storage temperature range Operating humidity -20 C to +50 C (-4 F to 122 F) Operating and storage 10 % to 95 %, Non-condensing Vibration and shock 2G, IEC 68-2-26 and 25G, IEC 68-2-29 Safety standards CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01 C Tick IEC/EN 61326-1 EMI, RFI, EMC EN61326-1; FCC Part 5 User manuals Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish, Dutch, and Hungarian Standard warranty period Extended warranty and service plans Two-years Yes Ordering information FLK-Ti125 30HZ FLK-Ti125 9HZ FLK-Ti110 30HZ FLK-Ti110 9HZ FLK-Ti105 30Hz FLK-Ti105 9HZ FLK-Ti100 9HZ Industrial-Commercial Thermal Imager Industrial-Commercial Thermal Imager Industrial-Commercial Thermal Imager Industrial-Commercial Thermal Imager Industrial-Commercial Thermal Imager Industrial-Commercial Thermal Imager General Use Thermal Imager CNX wireless modules FLK-CNX i3000 iFlexTM AC Current Clamp Module FLK-CNX a3000 AC Current Clamp Module FLK-CNX v3000 AC Voltage Module FLK-CNX t3000 K-Type Temperature Module Included with product Thermal imagers are shipped with ac power adapter, lithium ion smart battery (Ti125 includes 2 each--other models 1 each), USB cable, SD memory card, hard carrying case, soft transport bag, adjustable hand strap (left- or right-handed use), printed users manual in English, Spanish, French, German and Simplified Chinese, others on CD, SmartView(R) software and warranty registration card. Ti125 model also include a two-bay charging base and a multi-format USB memory card reader. Optional FLK-TI-VISOR2 FLK-TI-TRIPOD2 BOOK-ITP FLK-TI-SBC3 FLK-TI-SBP3 TI-CAR CHARGER TM Sun visor Tripod mounting accessory Introduction to Thermography Principles Book External charging base and power supply Extra lithium-ion rechargeable smart battery Thermal imager vehicle charger Not available in all countries. For more information on CNXTM wireless thermal imagers and other CNXTM solutions go to www.fluke.com/cnx 3 Fluke Corporation Ti125, Ti110, Ti105 Industrial/Electrical and Ti100 General Use Thermal Imagers Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A. Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com (c)2012-2013 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 3/2013 4026524D_EN Modification of this document is not permitted without written permission from Fluke Corporation. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Fluke: FLK-TI105 30HZ