Nominal
Fuse Voltage
Rating (kV)
Current
Rating
(Amps)
Fuse
Catalog
Number
Rated
Maximum
Voltage (kV)
Maximum Continuous
Current (in Oil @ 60°C)
(5)
Peak Arc
Voltage
(6) (kV)
Minimum
Melt I2t
(AMP2
-SEC)
Maximum
Melt I2t (3) (4)
(AMP2
-SEC)
5.5
100 HTSX320100
5.5
114.0
15
22,100 110,000
150 HTSX320150 147.0 56,700 280,000
175 HTSX320175 172.0 78,300 380,000
225 HTSX320225 230.0 176,000 860,000
250 HTSX320250 253.0 259,000 1,270,000
8.3
5 HTSX230005
10.0
5.0 30 100 350
10 HTSX230010 11.5 32 620 2,700
12 HTSX230012 14.0 28 800 4,000
15 HTSX230015 17.0 28 800 4,000
20 HTSX230020 22.5 26 920 8,000
25 HTSX230025 25.0 26 1,310 9,500
30 HTSX230030 30.0 26 1,620 11,000
40 HTSX230040 43.0 26 3,660 22,000
50 HTSX230050 53.0 26 5,250 30,000
65 HTSX230065 65.0 26 8,700 50,000
75 HTSX230075 75.0 26 12,800 70,000
90 HTSX330090
8.3
92.0
25
25,200 100,000
100 HTSX330100 105.0 47,500 185,000
150 HTSX330150 150.0 78,300 330,000
160 HTSX330160 163.0 115,150 480,000
15.5
5 HTSX240005
17.2
5.0 51 100 510
10 HTSX240010 11.5 54 620 2,600
12 HTSX240012 14.0 46 800 3,700
15 HTSX240015 17.0 46 800 3,700
20 HTSX240020 22.5 43 920 6,500
25 HTSX240025 25.0 45 1,310 8,000
30 HTSX240030 30.0 45 1,620 10,000
40 HTSX240040 43.0 45 3,660 22,000
50 HTSX240050 53.0 45 5,250 30,000
65 HTSX240065 65.0 45 8,700 50,000
75 HTSX240075 75.0 45 12,800 70,000
90 HTSX340090
15.5
98.0
40
25,200 110,000
100 HTSX340100 117.0 39,400 185,000
150 HTSX340150 150.0 80,000 380,000
23.0
10 HTSX250010
23.0
11.5 67 620 3,100
12 HTSX250012 14.0 61 800 4,800
15 HTSX250015 17.0 61 800 4,800
20 HTSX250020 22.5 60 920 8,300
25 HTSX250025 25.0 60 1,310 11,200
30 HTSX250030 30.0 60 1,620 13,000
40 HTSX250040 42.0 60 3,660 28,000
50 HTSX250050 51.0 60 5,250 38,000
65 HTSX250065 65.0 60 8,700 61,000
TABLE 22 – ELECTRICAL CHARACTERISTICS OF TRANS-GUARD™ SX FUSES
NOTES:
1. Designs have a 50,000 Amps rms. Symmetrical Rating (except 5A 17.2kV which was tested at 44kA maximum).
2. Fuses rated 75A and below are 2.25” in diameter. Higher ratings are 3.3” in diameter.
3. Tabulated Maximum Total I
2
t values are for currents of 50,000 amperes at the nominal voltage of the fuse. Fuses which have a Rated Maximum Voltage higher
than their Nominal Voltage Rating will have a higher I
2
t let-through when applied at voltages up to these higher values. For example, Maximum Total I
2
t values are
increased by approximately 30% when 8.3kV fuses are applied at 10 kV and approximately 25% when 15.5kV fuses are used at 17.2 kV.
4. Maximum total I
2
t values are reduced for currents below 50,000 A. For example, at 10,000 A, I
2
t values are approximately 15% less than the published values.
5. Maximum continuous currents at different ambient temperatures: These may be determined by derating the fuses by 0.2% per degree C over 60°C (for example at
80°C the derating would be 20 x .2 = 4%, making the maximum continuous current of a 20 A fuse 22.5 x .96 = 21.6A) or rerating the fuses by .2 % per degree C under
60°C (for example at 40°C the rerating would be 20 x .2 = 4 %, making the maximum continuous current of a 20 A fuse 22.5 / .96 = 23.4A). The long time melting
current of the fuses (approximately one hour and longer) due to different ambient temperatures is the same as described above for “maximum continuous currents”.
See time current characteristics for melting characteristics in this time region.
6. Peak arc voltages quoted are for 50,000 A currents at the rated maximum voltage listed.
Reduced currents and voltages will reduce the peak arc voltage. Consult the factory for further information.
PROTECTION AND CONTROL
24
Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utility
SX Full-Range
CL Fuses
PG-PC-H-0307
Trans-Guard™ SX Fuses