Subject to changes. Please also observe the further product documentation!
WAGO Kontakttechnik GmbH & Co. KG
Hansastr. 27
We are always happy to take your call at +49 (571) 887-44222.
Assemble terminal blocks without pole loss
Available in tape-and-reel packaging for automated assembly
Note:
Application notes:
Suitable for lead-free, reflow-soldering profiles per DIN EN 61760-1 and IEC 60068-2-58 up to max. 260°C peak temperature. Due to application-
specific variables (component configuration and orientation, type of soldering machine, solder paste), trial runs are recommended to ensure
product and process compatibility under actual manufacturing conditions.
Note:
Depending on reflow soldering temperatures and times, color deviations may occur. These deviations will have no impact on functionality.
Recommendation:
Recommendation for stencil:
Material thickness: 150 µm; Pattern layout identical to solder pad layout
Data
Electrical data
Ratings per IEC/EN 60664-1
Ratings per IEC/EN 60664-1
Nominal voltage (III/3) 63 V
Rated surge voltage (III/3) 2.5 kV
Rated voltage (III/2) 160 V
Rated surge voltage (III/2) 2.5 kV
Nominal voltage (II/2) 320 V
Rated surge voltage (II/2) 2.5 kV
Rated current 3 A
Legend (ratings) (III / 2) ≙ Overvoltage category III / Pollution degree 2
Ratings per UL 1059
Approvals per UL 1059
Ratings per UL 1977
Rated voltage UL 1977 250 V
Rated current UL 1977 3 A