MIL-PRF-19500/304F
10
4.4.2.2 Quality levels JAN, JANTX and JANTXV.
Subgroup Method Condition
B2 1051 Insulated types -55°C to + 175°C; uninsulated types -55°C to + 175°C.
B2 4066 Condition A, TC = 100°C; VR = rated VR (see 1.3), six surges, one surge per minute
maximum, tp = 8.3 ms.
Non-A version devices, IFS = 150 A; IO = 12 A dc
A version devices, IFS = 225 A; IO = 20 A dc.
B3 1037 0.25 rated IO < IO applied < rated IO (see 4.5.4) 2,000 cycles. For irradiated devices,
include trr as an end-point measurement.
B3 1038 Condition A; 340 hrs (separate samples may be used). For irradiated devices, include
or trr as an end-point measurement.
1049
B5 Not applicable.
B6 1032 TA = 150°C.
4.4.3 Group C inspection. Group C inspection shall be conducted in accordance with the conditions specified for
subgroup testing in appendix E, table E-VII of MIL-PRF-19500 and as follows. Delta electrical measurements shall
be in accordance with table III herein.
Subgroup Method Condition
C2 1056 Test condition B.
C2 2036 Tension, test condition A, t = 15 s.
For 1N3885, A, 1N3886, A, 1N3888, A weight = 5 pounds (2.27 kg).
For 1N3890, A, R, AR, 1N3891, A, R, AR, 1N3893, A, R, AR,
weight = 20 pounds (9.07 kg).
C2 2036 Bending stress, test condition F, method B: t = 15 s.
For 1N3885, A, 1N3886, A, 1N3888, A weight = 1 pounds (0.45 kg).
For 1N3890, A, R, AR, 1N3891, A, R, AR, 1N3893, A, R, AR,
weight = 5 pounds (2.27 kg).
C2 2036 Seal torque, test condition D1, torque = 10 oz-inches (0.07 N-m), t = 15 s.
C5 3101 RθJC = rated RθJC (see 1.4); IM = 50 mA ≤ IM ≤ 250 mA; tH = 30 s minimum;
tMD = 50 to 300 µs.
C6 1037 0.25 rated IO < IO applied < rated IO (see 4.5.4) 6,000 cycles. For irradiated devices,
include trr as an end-point measurement.
4.4.4 Group E inspection. Group E inspection shall be conducted in accordance with the conditions specified for
subgroup testing in appendix E, table E-IX of MIL-PRF-19500, and table II herein. Delta electrical measurements
shall be in accordance with table III herein.