T
F
E
W
11
frame
transformount
mers
Finish Options
Voltage Output
Style
Output Power
Part Numbering System
Example - L 030 F 15 I
030 = 30VA
040 = 40VA
050 = 50VA
080 = 80VA
100 = 100VA
* Available for certain sizes - please call for details.
06 = 2x6V*
09 = 2x9V*
12 = 2x12V*
15 = 2x15V
18 = 2x18V
20 = 2x20V
24 = 2x24V
T = Thermal cutout*
L = Flying leads*
I = Vacuum impregnation
E = Additional Enveloping*
S = Single 230V Input
F = Frame
Example L030F15I = Frame mounted 115V/230V input, 2x15V output, 30VA transformer
with vacuum impregnated varnish finish and solder tag termination.
Frame Mount Transformers
*Recommended fixing centres
E
16 Slots 'G'
D
B
F
A
C
30 0.64 20 70 59 45 51 45 35 7 x 4
40 0.68 15 70 59 45 60 45 45 7 x 4
50 1 10 79 67 54 56 54 40 8 x 4
80 1.5 9 89 75 57 64 57 43 8 x 4 7
100 2.0 6 99 83 64 71 64 43 8 x 4 7
Power Mass Regulation A B C* D E* F* G
(VA) (kg) (%) (mm) (mm) (mm) (mm) (mm) (mm) (mm)
• Input voltages, single
230V or dual
115V/230V
50/60Hz
• Reinforced insulation -
tested at 3kVrms
• Transformers dip
coated in varnish as
standard
• Solder tag
terminations
• Operational ambient
temperature range
-20°C to +50°C
CONTACT US NOW
UNITED KINGDOM
CRYDOM
+44 (0) 1202 897969
+44 (0) 1202 891918
magnetics@crydom.com
www.crydom.co.uk
T
F
E
W
10
C
F
E
D
A
B
*Recommended fixing centres
Power Mass Regulation A B* C D E F
(VA) (kg) (%) (mm) (mm) (mm) (mm) (mm) (mm)
3 0.17 20 45 54 16 35 23 37
6 0.23 20 50 60 18 38 25 41
12 0.31 20 56 68 20 41 28 47
20 0.53 15 59 73 28 52 31 50
30 0.64 20 70 83 24 51 36 56
40 0.68 15 70 83 34 60 36 56
50 1 10 78 92 27 56 41 65
Chassis Transformers
Part Numbering System
Example - L 003 C 15 I
003 = 3VA
006 = 6VA
012 = 12VA
020 = 20VA
030 = 30VA
040 = 40VA
050 = 50VA
* Available for certain sizes - please call for details.
06 = 2x6V
09 = 2x9V
12 = 2x12V
15 = 2x15V
18 = 2x18V
20 = 2x20V
24 = 2x24V
T = Thermal cutout*
L = Flying leads*
I = Vacuum impregnation
E = Additional Enveloping*
S = Single 230V Input
C = chassis
Example L003C15I = Chassis mounted 115V/230V input, 2x15V output, 3VA transformer
with vacuum impregnated varnish finish and solder tag termination.
• Input voltages,
single 230V or dual
115V/230V
50/60Hz
• Reinforced isolation -
tested at 3kVrms
• Transformers dip
coated in varnish as
standard
• Solder tag
terminations
• Operational ambient
temperature range
-20°C to +50°C
Finish Options
Voltage Output
Style
Output Power
cha
transfor ssis
mers
USA
CRYDOM
+1 619 210 1600
+1 619 710 8540
sales@crydom.com