Preliminary Data Sheet
Part Number 856378
211 MHz SAW Filter
Electrical Specifications (1)
Operating Temperature Range: (2) 0 to +70 oC
Parameter (3) Minimum Typical Maximum Unit
Insertion Loss at 211 MHz (fc) - 5.2 6.5 dB
Center Frequency at 3dB
At 25 ºC
0 to 70 ºC
210.975
210.969
211
211
211.025
211.031
MHz
MHz
Lower 1.5 dB Bandedge (4)
Upper 1.5 dB Bandedge
-
211.05
210.88
211.12
210.95
-
MHz
MHz
Lower 2.0 dB Bandedge
Upper 2.0 dB Bandedge
-
211.08
210.86
211.14
210.92
-
MHz
MHz
Lower 3.0 dB Bandedge
Upper 3.0 dB Bandedge
-
211.10
210.83
211.17
210.90
-
MHz
MHz
Relative Attenuation (4)
fc – 20 MHz to fc – 0.8 MHz
fc – 0.8 MHz to fc – 0.6 MHz
fc – 0.6 MHz to fc – 0.4 MHz
fc + 0.4 MHz to fc + 0.6 MHz
fc + 0.6 MHz to fc + 0.8 MHz
fc + 0.8 MHz to fc + 2.85 MHz
fc + 2.85 MHz to fc + 3.10 MHz
fc + 3.10 MHz to fc + 20.0 MHz
46
38
25
25
38
46
44
46
50
45
30
33
44
49
48
49
-
-
-
-
-
-
-
-
dB
dB
dB
dB
dB
dB
dB
dB
Absolute Group Delay
210.9 - 211.1 MHz
-
2.4
5
µs
Group Delay Variation
210.9 - 211.1 MHz
-
370
500
ns
EVM (5) - 2 - %
Input\Output Return Loss
fc ± 0.05 MHz
fc ± 0.1 MHz
10
8
15
10
-
-
dB
dB
Out-of-Band Modulation (5)
Input signals + 10 dBm @ 209.4 & 210.2 MHz
Input signals + 10 dBm @ 211.8 & 212.6 MHz
-
-
-65
-65
-60
-60
dBm
dBm
Source Impedance (6) - 50 -
Ω
Load Impedance (6) - 50 -
Ω
Notes:
1. All specifications are based on the test circuit shown on page 4
2. In production, devices will be tested at room temperature to a guardbanded specification to ensure electrical compliance over
temperature. The guardbanded specification includes the 3 dB center frequency correlation factor between customer board and
Sawtek test fixture
3. Electrical margin has been built into the design to account for the variations due to temperature drift and manufacturing tolerances
4. All bandedge and relative attenuation measurements are referenced to the minimum insertion loss
5. EVM and out-of-band modulation will not be tested in production due to the complexity of test. Compliance guaranteed by design
6. This is the optimum impedance in order to achieve the performance shown
Subject to change or obsolescence without notice Rev B 13-Jun-2005 Page 2 of 5