MB Series Bridge Rectifiers Surface Mount Features: * * * Rating to 1,000 V PRV Ideal for printed circuit board Lead tin plated copper Reverse Voltage - 50 to 1,000 Volts Forward Current - 0.8 Ampere Dimensions : Inches (Millimetres) Mechanical Data Polarity Weight Mounting position : Symbol moulded on body : 0.0044 oz, 0.125 g : Any www.element14.com www.farnell.com www.newark.com Page <1> 29/09/11 V1.1 MB Series Bridge Rectifiers Surface Mount Maximum Ratings and Electrical Characteristics Rating at 25C ambient temperature unless otherwise specified Single phase, half wave, 60 Hz, resistive or inductive load For capacitive load, derate current by 20% Characteristics Symbol MB05S MB1S MB2S MB4S MB6S MB8S MB10S Unit Maximum Recurrent Peak Reverse Voltage VRRM 50 100 200 400 600 800 1,000 Maximum RMS Voltage VRMS 35 70 140 280 420 560 700 VDC 50 100 200 400 600 800 1,000 Maximum DC Blocking Voltage Maximum Average Forward Rectified Current (Note 1) at TA = 40C Peak Forward Surge Current 8.3 ms Single Half Sine-wave Peak Forward Voltage at 0.8 A dc Maximum DC Reverse Current at Rated DC Blocking Voltage at TJ = 25C at TJ = 125C Typical Junction Capacitance Per Element (Note 2) Typical Thermal Resistance (Note 3) Operating Temperature Range Storage Temperature Range I (AV) V 0.8 A IFSM 30 VF 1.1 V IR 5 500 A CJ 15 pF RJC 75 C/W -55 to +150 C TJ TSTG Notes: 1. Mounted on P C board 2. Measured at 1 MHz and applied reverse voltage of 4 V dc 3. Thermal resistance junction to case Maximum Non-Repetitive Surge Current Peak Forward Surge Current, Amperes Average Forward Current Amperes Forward Current Derating Curve Ambient Temperature, C Number of Cycles at 60 Hz www.element14.com www.farnell.com www.newark.com Page <2> 29/09/11 V1.1 MB Series Bridge Rectifiers Surface Mount Typical Forward Characteristics Instantaneous Forward Current, (A) Instantaneous Reverse Current, (A) Typical Reverse Characteristics Percent of Rated Peak Reverse Voltage, (%) Instantaneous Forward Voltage, Volts Capacitance (pF) Typical Junction Capacitance Reverse Voltage, Volts Important Notice : This data sheet and its contents (the "Information") belong to the members of the Premier Farnell group of companies (the "Group") or are licensed to it. No licence is granted for the use of it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted. Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict the Group's liability for death or personal injury resulting from its negligence. Multicomp is the registered trademark of the Group. (c) Premier Farnell plc 2011. www.element14.com www.farnell.com www.newark.com Page <3> 29/09/11 V1.1