Timers - Multifunctional E1ZM, E1Z1 ENYA series Up to 7 functions 7 time ranges Wide input voltage range 1 change over contact Width 17.5 mm Installation design Technical data 1. Functions The function has to be set before connecting the relay to the supply voltage. E ON delay R OFF delay Ws Single shot leading edge with control input Wa Single shot trailing edge with control input Es ON delay with control input Wu Single shot leading edge voltage controlled Bp Flasher pause first Function sets of the distinct types are according to table ordering information or printing on the unit. 2. Time ranges Time range 1s 10s 1min 10min 1h 10h 100h Adjustment range 50ms 1s 500ms 10s 3s 1min 30s 10min 3min 1h 30min 10h 5h 100h 3. Indicators Green LED U/t ON: Green LED U/t flashes: Yellow LED R ON/OFF: indication of supply voltage indication of time period indication of relay output 4. Mechanical design Self-extinguishing plastic housing, IP rating IP40 Mounted on DIN-rail TS 35 according to EN 60715 Mounting position: any Shockproof terminal connection according to VBG 4 (PZ1 required), IP rating IP20 Tightening torque: max. 1Nm Terminal capacity: 1 x 0.5 to 2.5mm with/without multicore cable end 1 x 4mm without multicore cable end 2 x 0.5 to 1.5mm with/without multicore cable end 2 x 2.5mm flexible without multicore cable end 6. Output circuit 1 potential free change over contact Rated voltage: 250V AC Switching capacity: 2000VA (8A / 250V) Fusing: 8A fast acting Mechanical life: 20 x 106 operations Electrical life: 2 x 105 operations at 1000VA resistive load Switching frequency: max. 6/min at 1000VA resistive load (in accordance with IEC 60947-5-1) Overvoltage category: III (in accordance with IEC 60664-1) Rated surge voltage: 4kV 7. Control input Input not potential free: terminals A1-B1 Loadable: yes Max. line length: 10m Trigger level (sensitivity): automatic adaption to supply voltage Min. control pulse length: DC 50ms / AC 100ms 8. Accuracy Base accuracy: Adjustment accuracy: Repetition accuracy: Voltage influence: Temperature influence: 1% of maximum scale value <5% of maximum scale value <0.5% or 5ms 0.01% / C 9. Ambient conditions Ambient temperature: Storage temperature: Transport temperature: Relative humidity: Pollution degree: -25 to +55C -25 to +70C -25 to +70C 15% to 85% (in accordance with IEC 60721-3-3 class 3K3) 2, if built-in 3 (in accordance with IEC 60664-1) 10. Weight Single packing: Package 10pcs: 72g 670g per Package 5. Input circuit Supply voltage: terminals A1(+)-A2 E1Z... 12-240VAC/DC: 12 to 240V AC/DC Tolerance: 12V -10% to 240V +10% E1Z... 24-240VAC/DC: 24 to 240V AC/DC Tolerance: 24V-15% to 240V+10% Rated consumption: 4VA (1.5W) Rated frequency: AC 48 to 63Hz Duty cycle: 100% Reset time: 100ms Residual ripple for DC: 10% Drop-out voltage: >30% of minimum rated supply voltage Overvoltage category: III (in accordance with IEC 60664-1) Rated surge voltage: 4kV www.tele-online.com E1ZM, E1Z1 Functions ON delay (E) When the supply voltage U is applied, the set interval t begins (green LED U/t flashes). After the interval t has expired (green LED U/t illuminated) the output relay R switches into on-position (yellow LED illuminated). This status remains until the supply voltage is interrupted. If the supply voltage is interrupted before the expiry of the interval t, the interval already expired is erased and is restarted when the supply voltage is next applied. U ON delay with control input (Es) The supply voltage U must be constantly applied to the device (green LED U/t illuminated). When the control contact S is closed, the set interval t begins (green LED U/t flashes). After the interval t has expired (green LED U/t illuminated) the output relay R switches into on-position (yellow LED illuminated). This status remains until the control contact is opened again. If the control contact is opened before the interval t has expired , the interval already expired is erased and is restarted with the next cycle. U LED U/t R LED U/t