VLPS-100-24 100W Single Output with PFC Function
V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005 www.v-infinity.com 1-866-372-1258
DC output voltage 24V
Output V. tolerance ±1%
Output rated current 4.2A
Output current range 0-4.2A (6.0A 10s)
Ripple & noise 150mVp-p
Line regulation ±0.5%
Load regulation ±0.5%
DC output power 100.8W (144A 10s)
Efficiency 80%
DC voltage adj. 20-26.4V
Input voltage range 88~132VAC / 176~264VAC selected by auto switch, 47~63Hz; or 248~370VDC
AC current 2.3A/115V 1.5A/230V
Inrush current cold start 60A/230V
Leakage current <1mA/240VAC
Overload protection 105%~140% (+24V Above 6.5A)
type: Hiccup mode, recovers automatically after fault condition is removed
Over voltage protection 3.8-4.45V
Over temp. protection -----
Temperature coefficient ±0.05% / °C (0~50°C)
Set up, rise, hold up time 800ms, 50ms, 20ms/230VAC 1.2s, 50ms, 20ms/115VAC
Vibration 10~500Hz, 2G 10min./1cycle (1 hour each axes)
Withstand voltage I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC, for 1 min.
Isolation resistance I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms min.
Working temp., humidity -10°C~+60% (refer to output derating curve), 20%-90% RH
Storage temp., humidity -20ºC~+85ºC, 10%~95% RH
Dimensions 8.74x2.44x1.26 inches (222x62x32 mm)
Weight 0.99 lbs (0.45 Kgs)
Safety standards UL60950, TUV EN60950
EMC standards CISPR22 (EN55022) CLASS B, EN61000-3-2,3; EN61000-4-2,3,4,5,11
Notes: 1. All parameters are specified at 230VAC input, rated load, 25°C 70% RH ambient
2. Tolerance includes set up tolerance, line regulation, load regulation
3. Ripple & noise are measured at 20MHz by using a 12” twisted pair terminated with a 0.1uF & 47 uF capacitor
4. Line regulation is measured from low line to high line at rated load
5. Short or overload condition continues more than 10 seconds, it will damage the components inside the power supply
6. For input range 85-89VAC, when the output current is stepped from 0% to 100% of the rated load, the output voltage may drop
20V for 1 second max
7. Mounting holes M1 and M2 should be grounded for EMI purposes
*V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise cus-
tomers to verify the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for cus-
tomer’s applications using V-Infinity products other than repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s pub-
lished specifications. Nothing will be covered outside of standard product warranty.
Features
·Universal AC input / Full range
·Protections:Short circuit/Over load/Over voltage
·Cooling by free air convection
·100% full load burn-in test
·Fix switching frequency at 134KHz
·3 years warranty