1
CSM_TL-M_DS_E_3_1
Compact Proximity Sensor
TL-M
As Easy To Install as a Microswitch
A compact Proximity Sensor with the feel of a microswitch.
Be sure to read Safety Precautions on
page 4.
Ordering Information
Note: Models with different frequencies are also available. The model numbers are TL-M@M@@5 (e.g., TL-M2ME15).
Ratings and Specifications
Appearance Sensing distance Output specifications
Model
Operation mode
NO NC
DC 3-wire, NPN voltage output TL-M2ME1 2M TL-M2ME2 2M
AC 2 wire TL-M2MY1 2M ---
DC 3-wire, NPN voltage output TL-M5ME1 2M TL-M5ME2 2M
AC 2 wire TL-M5MY1 2M ---
Item Model TL-M2ME1, TL-M2ME2, TL-M2MY1 TL-M5ME1, TL-M5ME2, TL-M5MY1
Sensing distance 2 mm ±10% 5 mm ±10%
Set distance 0 to 1.6 mm 0 to 4 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 2.)
Standard sensing object Iron, 15 × 15 × 1 mm
Response frequency E Models: 500 Hz, Y Models: 20 Hz E Models: 250 Hz, Y Models: 20 Hz
Power supply voltage
(operating voltage range)
E Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 20% max.
Y Models: 100 to 220 VAC (90 to 250 VAC), 50/60 Hz
Current consumption E Models: 15 mA max. at 24 VDC (no-load)
Leakage current Y Models: 2.5 mA max. at 200 VAC
Control
output
Load current E Models: 100 mA max. at 12 VDC, 200 mA max. at 24 VDC
Y Models: 10 to 200 mA
Residual
voltage
E Models: 1 V max.
Y Models: Refer to Residual Output Voltage under Engineering Data on page 3.
Indicators E Models: Detection indicator (red)
Y Models: Operation indicator (red)
Operation mode (with sens-
ing object approaching)
E1/Y1 Models: NO
E2 Models: NC
Protection circuits E Models: Reverse polarity protection, Surge suppressor
Y Models: Surge suppressor
Ambient temperature range Operating/Storage: 25 to 70°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Microswitch
type 2 mm
5 mm
Refer to the timing charts under I/O Circuit Diagrams on page 3 for details.
TL-M
2
Engineering Data (Typical)
Item Model TL-M2ME1, TL-M2ME2, TL-M2MY1 TL-M5ME1, TL-M5ME2, TL-M5MY1
Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
Voltage influence E Models: ±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
Y Models: ±1% max. of sensing distance at rated voltage in the rated voltage ±10% range
Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case
Dielectric strength E Models: 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Y Models: 2,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 10 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP67, in-house standards: oil-resistant
Connection method Pre-wired Models (Standard cable length: 2 m)
Weight (packed state) Approx. 75 g
Materials Case Heat-resistant ABS
Sensing surface
Accessories Instruction manual
Sensing Area Leakage Current
TL-M2@/M5@TL-M@MY1
Influence of Sensing Object Size and Material
TL-M2ME TL-M2MY1 TL-M5M
X
6
5
4
3
2
1
0468
Y
864202
TL-M5M
Standard sensing
object
Iron, 15 × 15
t = 1 mm
TL-M2M
Standard
sensing
object
Iron, 12 × 12
t = 1 mm
Distance X (mm)
Sensing Head Distance Y
(mm)
3
2
100 15090
0
1
6
5
4
A
250200
Power supply voltage (V)
Protective resistance
AC power
Leakage current (mA)
1.0
0.5
0
2.5
2.0
1.5
5040302010
X
d ×
d t = 1 mm
Side length of sensing object: d (mm)
Stainless steel
(SUS304)
Note: Does not operate for brass or aluminum.
Iron
Distance X (mm)
1.0
0.5
20100
2.5
2.0
1.5
X
504030
d ×
d t = 1 mm
Side length of sensing object: d (mm)
Stainless steel
(SUS304)
Aluminum
Iron
Brass
Distance X (mm)
2
1
100
6
5
4
3
6050403020
X
d ×
d t = 1 mm
Side length of sensing object: d (mm)
Stainless steel (SUS304)
Aluminum
Iron
Brass
Distance X (mm)
TL-M
3
I/O Circuit Diagrams
DC 3-Wire Models
AC 2-Wire Models
Residual Output Voltage
TL-M@MY1 at 100 VAC TL-M@MY1 at 200 VAC
Operation
mode
Output specifi-
cations Model Timing chart Output circuit
NO
NPN
TL-M2ME1
TL-M5ME1
NC TL-M2ME2
TL-M5ME2
100 VAC
A
50
V
ON
100
0105 20050 100 150
OFF
Load current (mA)
Residual output
voltage
Residual
load
voltage
Load voltage V
L
(V)
50
010 505
OFF
200100 150
V
A200 VAC
ON
Load current (mA)
20
Residual Output
Voltage
Residual
load
voltage
Load voltage VL (V)
Sensing object Present
None
Load (between brown
and black leads)
Operate
Reset
Output voltage (between
black and blue leads)
High
Low
Detection indicator (red) ON
OFF
*1. 200 mA max. (load current).
*2. When a transistor is connected.
100
4.7 k
2.2 *2
0 V
Tr
+V
*1
Load
Brown
Black
Blue
Output
Prox-
imity
Sensor
main
circuit
Sensing object Present
None
Load (between brown
and black leads) Operate
Reset
Output voltage (between
black and blue leads) High
Low
Detection indicator
(Red)
ON
OFF
Operation
mode Model Timing chart Output circuit
NO TL-M2MY1
TL-M5MY1
Sensing object Present
None
Load Operate
Reset
Operation indicator
(Red)
ON
OFF
Prox-
imity
Sensor
main
circuit
Load
Blue
Brown
TL-M
4
Safety Precautions
Refer to Warranty and Limitations of Liability.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Do not use this product under ambient conditions that exceed the
ratings.
Design
Influence of Surrounding Metal
When installing Sensors on metal surfaces or near metal, ensure that
the minimum distances given in the following table are maintained.
Influence of Surrounding Metal (Unit: mm)
Mutual Interference
When installing Sensors face-to-face or side-by-side, ensure that the
minimum distances given in the following table are maintained.
Mutual Interference (Unit: mm)
Note: Values in parentheses apply to Sensors operating at different
frequencies.
Mounting
The maximum tightening torque that should be applied to the
mounting screws is 0.98 N·m.
Dimensions
WARNING
Precautions for Correct Use
Model Distance A B C
TL-M2M 12 10 15
TL-M5M 18 25 30
A
BC
Note: For direct mounting, the distance “C” will equal 0 only in
the shaded section of the above left-side section.
Model Distance A B C D
TL-M2M 60 (30) 40 (0) 30 (0) 10 (0)
TL-M5M 120 (60) 80 (40) 70 (30) 50 (10)
AB
C D
(Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
10 dia.
23.3
18.7
4
18.7
17.5
28.45
25.4±0.2
11.9
49.2
4.36
4.2
Indicator *
E Models: 4-dia. vinyl-insulated round cable
with 3 conductors (Conductor
cross section: 0.2 mm2, Insulator
diameter: 1.2 mm), Standard
length: 2 m
Y Models: 4-dia. vinyl-insulated round cable
with 2 conductors (Conductor
cross section: 0.3 mm2, Insulator
diameter: 1.3 mm), Standard
length: 2 m
* E Models: Detection indicator (red),
Y Models: Operation indicator (red)
TL-M2M
25.4±0.2
11.9
49.2
18.7
10
24.7
4.2
4.36
10 dia.
23.3
17.5
28.45 Indicator *
E Models: 4-dia. vinyl-insulated round cable
with 3 conductors (Conductor cross
section: 0.2 mm2, Insulator diameter:
1.2 mm), Standard length: 2 m
Y Models: 4-dia. vinyl-insulated round cable
with 2 conductors (Conductor cross
section: 0.3 mm2, Insulator diameter:
1.3 mm), Standard length: 2 m
* E Models: Detection indicator (red),
Y Models: Operation indicator (red)
TL-M5M
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2008.11
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2008 All Right Reserved.