Data Sheet The miniature circuit breakers of the System pro M compact(R) series S 200 and S 200 M provide state-of-the-art safety and comfort. They stand out due to their high performance and the wide range of accessories and approvals. 2CDC021038S0012 2CDC021023S0012 System pro M compact(R) Miniature Circuit Breaker S 200/S 200 M Features -- Clear contact position indication in red/green ("real CPI") -- Unique, patented twin terminal with captive screws and an increased opening for cables up to max. 35 mm2, finger-proof (IP20) - - Busbar slot in the back for best visibility during installation - - High performance at an increased rated voltage for marine and industrial applications: 10 kA/15 kA at Un = 440 V AC acc. to IEC/EN 60947-2 -- Individual product identification code - - Approved acc. to IEC/EN 60898-1, IEC/EN 60947-2 and UL 1077/CSA 22.2 No. 235 for global use Miniature Circuit Breaker S 200/S 200 M Technical data S 200 S 200 M General Data Standards IEC/EN 60898-1, IEC/EN 60947-2 IEC/EN 60898-1, IEC/EN 60947-2 UL 1077 UL 1077, CSA 22.2 No. 235 Poles 1P, 2P, 3P, 4P, 1P+N, 3P+N Tripping Characteristics B, C, D, K, Z Rated current In Rated insulation voltage Ui 0.5 up to 63 A 250 V AC (phase to ground), 500 V AC (phase to phase) Rated frequency 50/60 Hz Overvoltage Category III Pollution Degree 3 IEC/EN 60898-1 Rated operational voltage Un Power frequency recovery voltage Umax 1P: 230/400 V AC; 1P+N: 230 V AC; 2P, 3P, 4P: 400 V AC; 3P+N: 400 V AC 1P: 253 V AC; 1P+N: 253 V AC; 2P, 3P, 4P: 440 V AC; 3P+N: 440 V AC; 1P: 72 V DC; 2P: 125 V DC Min. operating voltage Rated short-circuit capacity Icn 12 V AC, 12 V DC 6 kA 10 kA Energy limiting class (B, C up to 40 A) Rated impulse withstand voltage Uimp (1.2/50 s) 3 4 kV (test voltage 6.2 kV at sea level, 5 kV at 2,000 m) Dielectric test voltage 2.0 kV (50/60 Hz, 1 min) Reference temperature for tripping characteristics Electrical endurance B, C, D: 30 C In < 32 A: 20,000 ops. (AC), 1,000 ops. (DC); one cycle 2 s - ON, 13 s - OFF In 32 A: 10,000 ops. (AC), 1,000 ops. (DC); one cycle 2 s - ON, 28 s - OFF IEC/EN 60947-2 Rated operational voltage Ue 1P: 230 V AC; 1P+N: 230 V AC; 2P, 3P, 4P: 440 V AC; 3P+N: 440 V AC Power frequency recovery voltage Umax 1P: 253 V AC; 1P+N: 253 V AC; 2P, 3P,4P: 462 V AC; 3P+N: 462 V AC; 1P: 72 V DC; 2P: 125 V DC Min. operating voltage 12 V AC, 12 V DC Rated ultimate short-circuit breaking capacity Icu 10 kA 15 kA Rated service short-circuit breaking capacity Ics 7.5 kA 40 A: 11.2 kA 50, 63 A: Rated impulse withstand voltage Uimp (1.2/50 s) Dielectric test voltage Reference temperature for tripping characteristics Electrical endurance 7.5 kA 4 kV (test voltage 6.2 kV at sea level, 5 kV at 2,000 m) 2.0 kV (50/60 Hz, 1 min) B, C, D: 55 C; K, Z: 20 C In < 32 A: 20,000 ops. (AC), 1,000 ops. (DC); one cycle 2 s - ON, 13 s - OFF In 32 A: 10,000 ops. (AC), 1,000 ops. (DC); one cycle 2 s - ON, 28 s - OFF Data acc. to UL/CSA Rated voltage 480Y / 277 V AC Rated interrupting capacity Application Reference temperature for tripping characteristic Electrical endurance 6 kA Suppl. prot. for general use. Application Codes: TC2, OL0, SC: U1 B, C, D, K, Z: 25 C 6,000 ops. (AC), 6,000 ops. (DC); one cycle 1 s - ON, 9 s - OFF Mechanical data Housing Toggle Contact position indication Protection degree acc. to EN 60529 Mechanical endurance Shock resistance acc. to IEC/EN 60068-2-27 Vibration resistance acc. to IEC/EN 60068-2-6 Environmental conditions acc. to IEC/EN 60068-2-30 Insulation group II, RAL 7035 Insulation group I, RAL 7035 Insulation group II, black, sealable Marking on toggle (I ON/0 OFF), Real CPI (red ON/green OFF) IP20*, IP40 in enclosure with cover 20,000 ops. 25 g, 3 shocks, 11 ms 5 g, 20 cycles at 5...150...5 Hz with load 0.8 In 28 cycles with 55 C/90-96 % and 25 C/95-100 % Ambient temperature -25 ... +55 C Storage temperature -40 ... +70 C * Also fulfilling the requirements acc. to the protection degree IPXXB 2 - 2CDC002157D0201 Miniature Circuit Breaker S 200/S 200 M Technical data and tripping characteristics S 200 S 200 M Installation Terminal Failsafe bi-directional cylinder-lift terminal Cross-section of conductors (top/bottom) 35 mm 2 / 35 mm2 Cross-section of busbars (top/bottom) 10 mm 2 / 10 mm2 18 - 4 AWG 18 - 8 AWG Torque 2.8 Nm 25 in-Ibs. Screwdriver No. 2 Pozidrive Mounting On DIN rail 35 mm acc. to EN 60715 by fast clip Mounting position any Supply optional Dimensions and weight Mounting dimensions acc. to DIN 43880 Mounting dimension 1 Pole dimensions (H x D x W) 85 x 69 x 17.5 Pole weight approx. 125 g Combination with auxiliary elements Auxiliary contact Yes Signal/auxiliary contact Yes Shunt trip Yes Undervoltage release Yes Motor Operating Device Yes Tripping characteristics Acc. to Tripping characteristics IEC/EN 60898-1 B Rated current Thermal release In Currents: conventional non-tripping current I1 6 to 63 A 1.13 * I n conventional tripping current I2 1.45 * In C 0.5 to 63 A 1.13 * In 0.5 to 63 A 1.13 * In IEC/EN 60947-2 K 0.5 to 63 A 1.05 * I n Range of instantaneous tripping Tripping time >1h 3 * In 0.1 ... 45 s (In 32 A)/0.1 ... 90 s (In > 32 A) <1h >1h 1.45 * In <1h >1h 3) 1.2 * In <1h >2h 1.2 * In <1h >1h 1.2 * In <1h >2h 1.2 * In <1h 0.5 to 63 A 1.05 * I n 1.05 * I n 5 * In < 0.1 s 0.1 ... 15 s (In 32 A)/0.1 ... 30 s (In > 32 A) 10 * In < 0.1 s 0.1 ... 4 s (In 32 A)/0.1 ... 8 s (In > 32 A) 20 * In < 0.1 s 5 * In 3) 1.05 * I n Z Tripping time <1h >1h 1.45 * In D Electromagnetic release 2) 1) 10 * In not applicable 10 * In 3) 3) 14 * In > 0.2 s < 0.2 s not applicable 2 * In > 0.2 s 3 * In < 0.2 s 1) The thermal releases are calibrated to a nominal reference ambient temperature; for B, C, D the reference value is 30 C, for K and Z the reference value is 20 C. In the case of higher ambient temperatures, the current values fall by approx. 6 % for each 10 K temperature rise. 2) The indicated tripping values of electromagnetic tripping devices apply to a frequency of 50/60 Hz. The thermal release operates independent of frequency. 3) As from operating temperature (after I1 > 1h or, as applicable, 2h) 2CDC002157D0201 - 3 Miniature Circuit Breaker S 200/S 200 M Tripping characteristics B characteristic K characteristic 2CDC022108F0209 2CDC022060F0211 Z characteristic 2CDC022010F0211 4 - 2CDC002157D0201 D characteristic 2CDC022008F0211 2CDC022006F0211 C characteristic Miniature Circuit Breaker S 200/S 200 M Derating For installations of miniature circuit breakers at other temperatures than the reference value and installations of several miniature circuit breakers directly side by side, derating factors have to be considered. Deviating ambient temperature The rated value of the current of a miniature circuit breaker refers to a reference ambient temperature of 30 C for circuit breakers with the characteristics B, C and D and 20 C for circuit breakers with the characteristics K and Z. The following table contains the derating of the load capability at ambient temperatures from -40 C to 70 C for the characteristics B, C, D, K and Z. Tripping Rated characteristics B, C, D K, Z current In A 0.5 1.0 1.6 2.0 3.0 4.0 6.0 8.0 10.0 13.0 16.0 20.0 25.0 32.0 40.0 50.0 63.0 0.5 1.0 1.6 2.0 3.0 4.0 6.0 8.0 10.0 13.0 16.0 20.0 25.0 32.0 40.0 50.0 63.0 Maximum operating current at ambient temperature T - 40 C 0.67 1.33 2.13 2.67 4.0 5.3 8.0 10.7 13.3 17.3 21.3 26.7 33.3 42.7 53.3 66.7 84.0 0.66 1.32 2.12 2.65 4.0 5.3 7.9 10.8 13.2 17.2 21.2 26.5 33.1 42.3 52.9 66.1 83.3 - 30 C 0.65 1.29 2.07 2.58 3.9 5.2 7.7 10.3 12.9 16.8 20.7 25.8 32.3 41.3 51.6 64.5 81.3 0.64 1.27 2.04 2.55 3.8 5.1 7.6 10.2 12.7 16.6 20.4 25.5 31.9 40.8 51.0 63.7 80.3 - 20 C 0.62 1.25 2.00 2.49 3.7 5.0 7.5 10.0 12.5 16.2 20.0 24.9 31.2 39.9 49.9 62.4 78.6 0.61 1.22 1.96 2.45 3.7 4.9 7.3 9.8 12.2 15.9 19.6 24.5 30.6 39.2 49.0 61.2 77.2 - 10 C 0.60 1.20 1.92 2.40 3.6 4.8 7.2 9.6 12.0 15.6 19.2 24.0 30.0 38.5 48.1 60.1 75.7 0.59 1.17 1.88 2.35 3.5 4.7 7.0 9.4 11.7 15.2 18.8 23.5 29.3 37.5 46.9 58.6 73.9 0 C 0.58 1.15 1.85 2.31 3.5 4.6 6.9 9.2 11.5 15.0 18.5 23.1 28.9 37.0 46.2 57.7 72.7 0.56 1.12 1.79 2.24 3.4 4.5 6.7 8.9 11.2 14.5 17.9 22.4 28.0 35.8 44.7 55.9 70.4 10 C 0.55 1.11 1.77 2.21 3.3 4.4 6.6 8.8 11.1 14.4 17.7 22.1 27.6 35.4 44.2 55.3 69.6 0.53 1.06 1.70 2.12 3.2 4.2 6.4 8.5 10.6 13.8 17.0 21.2 26.5 33.9 42.4 53.0 66.8 20 C 0.53 1.05 1.69 2.11 3.2 4.2 6.3 8.4 10.5 13.7 16.9 21.1 26.4 33.7 42.2 52.7 66.4 0.50 1.00 1.60 2.00 3.0 4.0 6.0 8.0 10.0 13.0 16.0 20.0 25.0 32.0 40.0 50.0 63.0 30 C 0.50 1.00 1.60 2.00 3.0 4.0 6.0 8.0 10.0 13.0 16.0 20.0 25.0 32.0 40.0 50.0 63.0 0.47 0.94 1.50 1.87 2.8 3.7 5.6 7.5 9.4 12.2 15.0 18.7 23.4 29.9 37.4 46.8 58.9 Influence of adjacent devices Example If several miniature circuit breakers are installed directly side by side with high load on all poles, a correction factor has to be applied to the rated current (see table). If distance pieces are used, the factor is not to be considered. S201-C16 at T = 40 C No. of adjacent devices Factor F 1 1 2, 3 0.9 4, 5 0.8 6 0.75 Conditions of use 40 C 0.47 0.94 1.51 1.89 2.8 3.8 5.7 7.5 9.4 12.3 15.1 18.9 23.6 30.2 37.7 47.1 59.4 0.43 0.87 1.39 1.73 2.6 3.5 5.2 6.9 8.7 11.3 13.9 17.3 21.7 27.7 34.6 43.3 54.6 50 C 0.44 0.88 1.41 1.76 2.6 3.5 5.3 7.1 8.8 11.5 14.1 17.6 22.0 28.2 35.3 44.1 55.6 0.40 0.79 1.26 1.58 2.4 3.2 4.7 6.3 7.9 10.3 12.6 15.8 19.8 25.3 31.6 39.5 49.8 60 C 0.41 0.82 1.31 1.63 2.4 3.3 4.9 6.5 8.2 10.6 13.1 16.3 20.4 26.1 32.7 40.8 51.4 0.35 0.71 1.13 1.41 2.1 2.8 4.2 5.7 7.1 9.2 11.3 14.1 17.7 22.6 28.3 35.4 44.5 70 C 0.37 0.75 1.19 1.49 2.2 3.0 4.5 6.0 7.5 9.7 11.9 14.9 18.6 23.9 29.8 37.3 47.0 0.31 0.61 0.98 1.22 1.8 2.4 3.7 4.9 6.1 8.0 9.8 12.2 15.3 19.6 24.5 30.6 38.6 Values to use Calculation Result Load at ambient In (40 C), 15.1 A x 0.75 I n = 11.33 A temperature Factor F 40 C with 8 adjacent devices 2CDC002157D0201 - 5 Miniature Circuit Breaker S 200/S 200 M Accessories and dimensional drawing 2CDC092002F0212 Accessory overview H Auxiliary contact S2C-H6R (change-over contact) H-R Auxiliary contact S2C-H6-...R S/H Signal/Auxiliary contact S2C-S/H6R S/H (H) Signal/Auxiliary contact H-L Auxiliary contact S2C-H...L H-BF Auxiliary contact for bottom fitting S2C-H01 (1 per pole) S2C-H10 BP Mechanical tripping device S2C-BP NT Neutral disconnector S2C-Nt used as auxiliary contact S2C-S/H6R MOD-S* Motor operating device S2C-CM ST Shunt trip S2C-A... DDA 200 RCD-block DDA 20... UR Undervoltage release S2C-UA OR Overvoltage release S2C-OVP * In case of using S 200/S 200 M coupled with DDA 200, MOD-S does not operate in case of earth-leakage fault. 2CDC022007F0010 Dimensional drawing 6 - 2CDC002157D0201 ABB STOTZ-KONTAKT GmbH Eppelheimer Strae 82 69123 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-Mail: info.desto@de.abb.com You can find the address of your local sales organization on the ABB home page http://www.abb.com/contacts -> Low Voltage Products and Systems Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts - is forbidden without prior written consent of ABB AG. Copyright(c) 2012 ABB All rights reserved Brochure number 2CDC002157D0201pdf (04/12-pdf) Contact us