Printed-circuit board connector-BCVP-381RF- 9 GY-5438663
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Plug component, Nominal current: 8 A, Rated voltage (III/2): 160 V, Number of positions: 9, Pitch: 3.81 mm,
Connection method: Screw connection, Color: signal grey, Contact surface: Tin
The figure shows a 5-pos. version of
the product
Key commercial data
Packing unit 1 pc
Minimum order quantity 100 pc
Weight per Piece (excluding packing) 8.0 GRM
Custom tariff number 85366990
Country of origin Germany
Technical data
Dimensions
Height 12.5 mm
Pitch 3.81 mm
Dimension a 30.48 mm
General
Range of articles BCVP-RF
Insulating material group I
Rated surge voltage (III/3) 2.5 kV
Rated surge voltage (III/2) 2.5 kV
Rated surge voltage (II/2) 2.5 kV
Rated voltage (III/3) 160 V
Rated voltage (III/2) 160 V
Rated voltage (II/2) 320 V
Nominal current IN8 A
https://www.phoenixcontact.com/us/products/5438663
11/18/2014Page2/3
Printed-circuit board connector-BCVP-381RF- 9 GY-5438663
Technical data
General
Nominal cross section 1.5 mm²
Maximum load current 8 A (with 1.5 mm² conductor cross section)
Insulating material PA
Inflammability class according to UL 94 V0
Number of positions 9
Connection data
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 1.5 mm²
Conductor cross section stranded min. 0.2 mm²
Conductor cross section stranded max. 1.5 mm²
Conductor cross section stranded, with ferrule without plastic sleeve min. 0.25 mm²
Conductor cross section stranded, with ferrule without plastic sleeve max. 1.5 mm²
Conductor cross section stranded, with ferrule with plastic sleeve min. 0.25 mm²
Conductor cross section stranded, with ferrule with plastic sleeve max. 0.5 mm²
Conductor cross section AWG/kcmil min. 24
Conductor cross section AWG/kcmil max 16
2 conductors with same cross section, solid min. 0.2 mm²
2 conductors with same cross section, solid max. 0.5 mm²
2 conductors with same cross section, stranded min. 0.2 mm²
2 conductors with same cross section, stranded max. 0.75 mm²
2 conductors with same cross section, stranded, ferrules without plastic
sleeve, min. 0.25 mm²
2 conductors with same cross section, stranded, ferrules without plastic
sleeve, max. 0.34 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic
sleeve, min. 0.5 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic
sleeve, max. 0.5 mm²
Classifications
eCl@ss
eCl@ss 4.0 272607xx
eCl@ss 4.1 27260701
eCl@ss 5.0 27260701
eCl@ss 5.1 27260701
eCl@ss 6.0 27261101
eCl@ss 7.0 27440401
https://www.phoenixcontact.com/us/products/5438663
11/18/2014Page3/3
Printed-circuit board connector-BCVP-381RF- 9 GY-5438663
Classifications
eCl@ss
eCl@ss 8.0 27440401
ETIM
ETIM 3.0 EC001121
ETIM 4.0 EC002638
ETIM 5.0 EC002637
UNSPSC
UNSPSC 6.01 30211801
UNSPSC 7.0901 39121432
UNSPSC 11 39121432
UNSPSC 12.01 39121409
UNSPSC 13.2 39121432
Drawings
Diagram
100806040200
!=5-pos.
!
0
2
4
6
8
10
12
14
16
Ambienttemperature[°C]
Currentstrength [A]
Dimensioned drawing
a+4,3
(a+4,6)
4,8
a
(3,81)
3,54,3
(4,5)
19,1
10,4
6,6