cui.com
date 12/12/2014
page 1 of 7
SERIES: PSF-100 DESCRIPTION: AC-DC POWER SUPPLY
MODEL output
voltage
output
current1
output
power2
ripple
and noise3
efciency
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
PSF-100-A Vo1
Vo2
13.8
13.8
7.3
2.875 100 100
150 86
PSF-100-B
Vo1
Vo2
Vo3
13.8
13.8
5
6.2
2.875
3
100
100
150
100
85
PSF-100-C Vo1
Vo2
27.6
27.6
3.65
1.725 100 100
150 87
PSF-100-D
Vo1
Vo2
Vo3
27.6
27.6
5
3.1
1.725
3
100
100
150
100
85
Notes: 1. Vo2 battery discharge current must not exceed 50% of the rated power.
2. Maximum total combined power (rated power).
3. At 20 MHz bandwidth using a 12” twisted pair-wire, each output terminated with a 47 µF and 0.1 µF parallel capacitors.
PART NUMBER KEY
PSF-100 - X - XXX
Base Number
Output Voltage
A = 13.8 Vdc, 13.8 Vdc
B = 13.8 Vdc, 13.8 Vdc, 5 Vdc
C = 27.6 Vdc, 27.6 Vdc
D = 27.6 Vdc, 27.6 Vdc, 5 Vdc
Chassis
“blank” = open frame
CNF = enclosed
FEATURES
• up to 100 W continuous power
• universal input (90~264 Vac)
• built-in constant current limit circuitry
• alarm signal for AC OK and battery low
• short circuit, over load, over voltage, brown-out,
battery low, and battery polarity protections
• withstand 2G vibration test
• efficiency up to 87%
DISCONTINUED
For more information, please visit the product page | If your application requires forced air, view our Dc Fans
cui.com
date 12/12/2014 page 2 of 7
CUI Inc SERIES: PSF-100 DESCRIPTION: AC-DC POWER SUPPLY
INPUT
parameter conditions/description min typ max units
voltage 90
127
264
373
Vac
Vdc
surge voltage for maximum of 5 seconds 300 Vac
frequency 47 63 Hz
current at 115 Vac
at 230 Vac
2.0
1.2
A
A
inrush current at 115 Vac, cold start
at 230 Vac, cold start
35
70
A
A
leakage current at 264 Vac 1 mA
OUTPUT
parameter conditions/description min typ max units
line regulation low line to high line, at rated load
Vo1, Vo3 ±0.5 %
load regulation
10% to 100% rated load
Vo1
Vo3
±0.5
±1.5
%
%
voltage accuracy Vo1
Vo3
±2
±3
%
%
hold-up time at 115 Vac, full load
at 230 Vac, full load
8
50
ms
ms
setup time at 115/230 Vac, full load, cold start 800 ms
rise time at 115/230 Vac, full load 50 ms
adjustability Vo1 ±10 %
temperature coefcient Vo1, 0°C~50°C ±0.03 %/°C
AC OK PSF-100-A, PSF-100-C
PSF-100-B, PSF-100-D
TTL open collector output
relay contact output
battery low PSF-100-A, PSF-100-C
PSF-100-B, PSF-100-D
<12 V ±3%
<22 V ±3%
PROTECTIONS
parameter conditions/description min typ max units
over voltage protection Vo1, latch off mode 115 150 %
over current protection
auto recovery, hiccup mode
Vo1, Vo3
Vo2
110
100
%
%
battery cut off PSF-100-A, PSF-100-B
PSF-100-C, PSF-100-D
9.5
19
10
20
10.5
21
Vdc
Vdc
SAFETY & COMPLIANCE
parameter conditions/description min typ max units
isolation voltage
input to output
input to ground
output to ground
3,000
1,500
500
Vac
Vac
Vac
isolation resistance input to output at 500 Vdc 100 MΩ
safety approvals UL 60950-1, EN 60950-1
EMI/EMC1EN 55022, EN 61000-6-(1,3), EN 61000-3-(2,3),
EN 55024, EN 50204, EN 61204-3, EN 61000-4-(2, 3, 4, 5, 6, 8, 11)
MTBF PSF-100-A, PSF-100-B as per MIL-HDBK-217F
PSF-100-C, PSF-100-D as per MIL-HDBK-217F
103,400
92,100
hrs
hrs
RoHS 2011/65/EU
Note: 1. The power supply is considered a component which will be installed into a nal equipment. The nal equipment must be re-conrmed that it still meets EMC directives.
DISCONTINUED
For more information, please visit the product page | If your application requires forced air, view our Dc Fans
cui.com
date 12/12/2014 page 3 of 7
CUI Inc SERIES: PSF-100 DESCRIPTION: AC-DC POWER SUPPLY
Load vs. Input Voltage
(at 25°C)
DERATING CURVES
MECHANICAL
parameter conditions/description min typ max units
dimensions open frame: 123 x 95 x 31
enclosed: 129.5 x 97.5 x 37.5
mm
mm
weight open frame
enclosed
0.34
0.47
kg
kg
Load vs. Temperature
~
~
100
80
60
40
20
Ambient Temperature (°C)
Load (%)
Safe operating area
PSF-100-B-CNF & PSF-100-D-CNF
40
3020100-10-20
0
50 60 70
50
100
80
60
40
20
Input Voltage (Vac) 60 Hz
Load (%)
120
1151101051009590
0
264
All other models
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature see derating curve -20 70 °C
storage temperature -40 85 °C
operating humidity non-condensing 20 90 %
storage humidity non-condensing 10 90 %
vibration at 10~500 Hz, 10 min per cycle for 60 minutes
each test along the X, Y, and Z axis 2 G
DERATING CURVES
DISCONTINUED
For more information, please visit the product page | If your application requires forced air, view our Dc Fans
cui.com
date 12/12/2014 page 4 of 7
CUI Inc SERIES: PSF-100 DESCRIPTION: AC-DC POWER SUPPLY
CN2 Pin Connections
PIN Function
PSF-100-A, PSF-100-C3
1 AC OK
2 BAT LOW
3PSF-100-A: (13.8 V/20 mA)
PSF-100-C: (27.6 V/20 mA)
PSF-100-B, PSF-100-D4
1 2 AC OK
3 4 BAT LOW
CN2 Pin Connections
PIN Function
PSF-100-A, PSF-100-C3
1 AC OK
2 BAT LOW
3PSF-100-A: (13.8 V/20 mA)
PSF-100-C: (27.6 V/20 mA)
PSF-100-B, PSF-100-D4
1 2 AC OK
3 4 BAT LOW
MECHANICAL DRAWING
units: mm
units: mm
CN1 Pin Connections
PIN Function
1 AC/L
2 AC/N
3 FG
4-Vo1
5 +Vo1
6 +Vo2 (+ BAT)
71-Vo2 (- BAT)
82+Vo3 (+5 V)
CN1 Pin Connections
PIN Function
1 AC/L
2 AC/N
3 FG
4-Vo1
5 +Vo1
6 +Vo2 (+ BAT)
71-Vo2 (- BAT)
82+Vo3 (+5 V)
CNF
OPEN FRAME
Notes: 1. To protect product damage do not connect the GND port with -BAT port.
2. PSF-100-B and PSF-100-D only.
3. For PSF-100-A & PSF-100-C, CN2 mates with JST XHP-3 or equivalent
and JST SXH-001 T-P0.6 or equivalent.
4. For PSF-100-B & PSF-100-D, CN2 mates with JST XHP-4 or equivalent
and JST SXH-001 T-P0.6 or equivalent.
MECHANICAL DRAWING
DISCONTINUED
For more information, please visit the product page | If your application requires forced air, view our Dc Fans
cui.com
date 12/12/2014 page 5 of 7
CUI Inc SERIES: PSF-100 DESCRIPTION: AC-DC POWER SUPPLY
BATTERY CHARGING SPECIFICATIONS
PSF-100-A & PSF-100-C
Alarm Signal for AC OK and Battery Low
Internal Circuit of AC OK and Battery Low
Function Description Alarm Output
AC OK
The signal is low when the power
supply turns on
Low
(0.3 V max. at 30 mA)
The signal is high when the power
supply turns off
High/open
(external voltage < 50 V)
Battery
Low
The signal is low when the voltage of
the battery is below:
12 V (PSF-100-A), 22 V (PSF-100-C)
Low
(0.3 V max. at 30 mA)
The signal is high when the voltage of
the battery is above:
12 V (PSF-100-A), 22 V (PSF-100-C)
High/open
(external voltage < 50 V)
Notes: 1. Alarm signal is sent out through “AC OK” and “Battery Low” pins.
2. An external voltage source is required for this function. The maximum applied voltage is 50 V and the maximum sink current is 30 mA.
PSF-100-A:
PSF-100-C:
Block Diagram
y
Alarm Circuit for
PSF-100-A & PSF-100-C
Alarm Circuit for
PSF-100-B & PSF-100-D
DISCONTINUED
For more information, please visit the product page | If your application requires forced air, view our Dc Fans
cui.com
date 12/12/2014 page 6 of 7
CUI Inc SERIES: PSF-100 DESCRIPTION: AC-DC POWER SUPPLY
PSF-100-B & PSF-100-D
Alarm Signal for AC OK and Battery Low
Internal Circuit of AC OK and Battery Low
Function Description Alarm Output
AC OK
The signal is low when the power
supply turns on Low or short
The signal is high when the power
supply turns off
High/open
(external voltage < 30 V)
Battery
Low
The signal is low when the voltage of
the battery is below:
12 V (PSF-100-B), 22 V (PSF-100-D)
Low or short
The signal is high when the voltage of
the battery is above:
12 V (PSF-100-B), 22 V (PSF-100-D)
High/open
(external voltage < 30 V)
Notes: 1. Alarm signal is sent out through “AC OK” and “Battery Low” pins (relay contact type).
2. An external voltage source is required for this function. The maximum applied voltage is 30 V and the maximum sink current is 1 A.
Notes: 1. All specications measured at 25°C, 230Vac input voltage, and rated power unless otherwise noted.
BATTERY CHARGING SPECIFICATIONS (CONTINUED)
DISCONTINUED
For more information, please visit the product page | If your application requires forced air, view our Dc Fans
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
date 12/12/2014 page 7 of 7
CUI Inc SERIES: PSF-100 DESCRIPTION: AC-DC POWER SUPPLY
rev. description date
1.0 initial release 11/25/2013
1.01 updated datasheet 12/12/2014
The revision history provided is for informational purposes only and is believed to be accurate.
REVISION HISTORY
DISCONTINUED
For more information, please visit the product page | If your application requires forced air, view our Dc Fans
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
CUI Inc.:
PSF-100-D PSF-100-B PSF-100-D-CNF PSF-100-A-CNF PSF-100-C-CNF PSF-100-C PSF-100-B-CNF PSF-
100-A