www.clare.com
LCA210
Rev. 7
Electrical Characteristics
Absolute Maximum Ratings are stress ratings. Stresses
in excess of these ratings can cause permanent damage
to the device. Functional operation of the device at these
or any other conditions beyond those indicated in the
operational sections of this data sheet is not implied.
Exposure of the device to the absolute maximum ratings
for an extended period may degrade the device and effect
its reliability.
Absolute Maximum Ratings (@ 25˚ C)
2
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics @ 25°C
Load Voltage (Peak) - VL- - 350 V
Load Current (Continuous) - IL-- 85mA
Peak Load Current 10ms max ILPK - - 170 mA
On-Resistance IL=85mA RON -25 35Ω
Off-State Leakage Current VL=350V ILEAK -- 1µA
Switching Speeds
Turn-On IF=8mA, VL=10V TON -- 3ms
Turn-Off IF=8mA, VL=10V TOFF -- 3ms
Output Capacitance 50V; f=1MHz COUT -25 - pF
*Input Characteristics @ 25°C
Input Control Current IL=120mA IF8 - 100 mA
Input Dropout Current - - 0.8 1.4 - mA
Input Voltage Drop IF=8mA VF0.9 1.2 1.4 V
Reverse Input Voltage - VR-- 5V
Reverse Input Current VR=5V IR- - 20 µA
Input to Output Capacitance - CI/O -3 -pF
Input to Output Isolation - VI/O 3750 - - VRMS
*Input characteristics represent requirements of two parallel connected LEDs.
Parameter Min Typ Max Units
Input Power Dissipation - - 1501mW
Input Control Current - - 100 mA
Peak (10ms) - - 1 A
Reverse Input Voltage - - 5 V
Total Power Dissipation - - 8002mW
Isolation Voltage
Input to Output 3750 - - VRMS
Operational Temperature -40 - +85 °C
Storage Temperature -40 - +125 °C
Soldering Temperature
DIP Package - - +260 °C
Flatpack/Surface Mount
Package - - +220 °C
(10 Seconds Max.)
1Derate Linearly 1.33 mw/˚C
2Derate Linearly 6.67 mw/˚C