350mA
LPC-100-350 LPC-100-500 LPC-100-700
LPC-100-1050
LPC-100-1400
LPC-100-1750
LPC-100-2100
500mA 700mA 1050mA 1750mA 2100mA
1400mA
100W
100 ~ 200V
100.1W
72 ~ 143V
100.8W
48 ~ 96V
100.8W
36 ~ 72V
101.5W
29 ~ 58V
100.8W
24 ~ 48V
1.5Vp-p 1Vp-p 1Vp-p 1Vp-p 1Vp-p 1Vp-p
220 ~ 240V 160 ~ 172V 108 ~ 120V 80 ~ 97V 65 ~ 80V 58 ~ 68V
IP67 approved,Design refer to TUV EN60950-1
16ms/230VAC 10ms/115vac at full load
1000ms, 80ms / 230VAC 2000ms,80ms/115VAC at full load
90 ~ 264VAC 127VDC ~ 370VDC
VOLTAGE TOLERANCE ±1.5%
SPECIFICATION
MODEL
RATED CURRENT
RATED POWER
OUTPUT
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.2
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER VOLTAGE
47 ~ 63Hz
2.2 A / 115VAC 1.2A / 230VAC
<0.25mA / 240VAC
-25 ~ +50 (Refer to "Derating Curve")℃
10 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±0.03%/ (0 ~ 50 )℃℃
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
RIPPLE CURRENT
ENVIRONMENT
SAFETY &
EMC
PROTECTION
315 ~ 345V
Protection type : Shut down and latch off o/p voltage re-power on to recovery
SHORT CIRCUIT
90% 89.5% 89%
±5%
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Derating may be needed under low input voltages. Please check the static characteristics for more details.
3. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
4. Refer to warranty statement.
5. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
6.Suitable for indoor use or outdoor use without direct sunlight exposure, please avoid immerse in the water over 30minutes.
7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level , criteria A
100.1W
143 ~ 286V
I/P-O/P:3KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
100W Single Output LED Power Supply LPC-100 series
File Name:LPC-100-SPEC 2015-03-19
EMC IMMUNITY
EMC EMISSION
CURRENT ACCURACY ±5.0%
Compliance to EN55022(CISPR22) Class B; EN61000-3-2 Class A( 80% load); EN61000-3-3≦
CONSTANT CURRENT REGION Note.5
RIPPLE & NOISE
1.5Vp-p
511Khrs min. MIL-HDBK-217F (25 )℃
190*52*37mm (L*W*H)
0.61Kg;20pcs/13.2Kg/0.55CUFT
LINE REGULATION ±1%
COLD START 75A(twidth=980 s measured at 50% Ipeak) at 230VACμ
Hiccup mode, recovers automatically after fault condition is removed