KBL400 - KBL410 SILICON BRIDGE RECTIFIERS
PRV : 50 - 1000 Volts
Io : 4.0 Amperes
* High current capability
* High surge current capability
* Low forward voltage drop
* Ideal for printed circuit board
* Epoxy : UL94V-O rate flame retardant
* Terminals : Plated lead solderable per
MIL-STD-202, Method 208 guaranteed
* Polarity : Polarity symbols marked on case
* Mounting position : Any
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
SYMBOL KBL
KBL
KBL
KBL
KBL
KBL
KBL
UNIT
Maximum Recurrent Peak Reverse Voltage VRRM 50 100 200 400 600 800 1000 Volts
Maximum RMS Voltage VRMS 35 70 140 280 420 560 700 Volts
Maximum DC Blocking Voltage VDC 50 100 200 400 600 800 1000 Volts
Maximum Average Forward Current Tc=50°CIF(AV) 4.0 Amps.
Peak Forward Surge Current Single half sine wave
Superimposed on rated load (JEDEC Method) IFSM 200 Amps.
Rating for fusing ( t < 8.3 ms. ) I2t166 A2S
Maximum Forward Voltage per Diode at IF = 4 Amps. VF1.1 Volts
Maximum DC Reverse Current Ta = 25 °CIR10 µA
at Rated DC Blocking Voltage Ta = 100 °CIR(H) 1.0 mA
Typical Thermal Resistance ( Note 1 ) RθJA 10 °C/W
Operating Junction Temperature Range TJ - 50 to + 150 °C
Storage Temperature Range TSTG - 50 to + 150 °C
1 ) Thermal resistance from Junction to Ambient with units mounted on a 3" X 3" X 0.11" THK ( 7.5cm X 7.5cm X 0.3cm ) Cu. plate.
UPDATE : APRIL 23,1998
RATING
0.085 (2.16)
0.065 (1.65)
KBL
0.77 (19.56)
0.265 (6.73 )
0.235 (5.97)
0.200 (5.08)
0.190 (4.82)
0.052 (1.32)
0.048 (1.22)
Dimensions in inches and ( millimeter )
AC AC
0.825 (20.95)
0.605 (15.36)
1.00 (25.4)
MIN.