11
E3FA/E3RA/E3FB/E3RB
Ratings and Specifications
Straight type (E3FA/E3FB)
* IP69K Degree of Protection Specifications
IP69K is a protection specification stipulated by DIN 40050 Part 9 of the German standards.
The test item is sprayed with 80°C water from a nozzle of a specified shape at a water pressure of 80 to 100 bar. The amount of water
is 14 to 16 liters per minute.
The distance between the test item and the nozzle is 10 to 15 cm. The water is discharged at angles of 0°, 30°, 60°, and 90° from
the horizontal plane for 30 seconds at each angle while the test item is rotated horizontally.
Sensing method Through-beam Retro-reflective with
MSR function
Coaxial Retro-reflective
with MSR function
Model NPN
output
Pre-wired E3F@-TN11 2M E3FA-TN12 2M E3F@-RN11 2M E3F@-RN12 2M
M12 Connector
E3F@-TN21 E3FA-TN22 E3F@-RN21 E3F@-RN22
PNP
output
Pre-wired E3F@-TP11 2M E3FA-TP12 2M E3F@-RP11 2M E3F@-RP12 2M
Item
M12 Connector
E3F@-TP21 E3FA-TP22 E3F@-RP21 E3F@-RP22
Sensing distance 20 m 15 m 0.1 to 4 m
(with E39-R1S)
0 to 500 mm
(with E39-R1S)
Spot diameter (reference value) —
Standard sensing object Opaque: 7 mm dia.min. Opaque: 75 mm dia.min.
Differential travel —
Directional angle 2° min.
Light source (wavelength) Red LED (624 nm) Infrared LED (850 nm) Red LED (624 nm)
Power supply voltage 10 to 30 VDC (include voltage ripple of 10%(p-p) max.)
Current consumption 40 mA max.
(Emitter 25 mA max. Receiver 15 mA max.) 25 mA max.
Control output NPN/PNP (open collector)
Load current: 100 mA max. (Residual voltage: 3 V max.), Load power supply voltage: 30 VDC max.
Operation mode Light-ON/Dark-ON selectable by wiring
Indicator
Operation indicator (orange)
Stability indicator (green)
Power indicator (green): only Emitter of Through-beam
Protection circuits
Power supply reverse polarity protection, Output short-circuit protection, and Output reverse polarity protection
Response time 0.5 ms
Sensitivity adjustment One-turn adjuster
Ambient illumination (Receiver side)
Incandescent lamp: 3,000 lx max./ Sunlight: 10,000 lx max.
Ambient temperature range Operating: -25 to 55°C/ Storage: -40 to 70°C (with no icing or condensation)
Ambient humidity range Operating: 35 to 85%/ Storage: 35 to 95% (with no condensation)
Insulation resistance 20 MΩ min. at 500 VDC
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min. between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance Destruction: 500 m/s2 3 times each in X, Y and Z directions
Degree of protection IEC: IP67, DIN 40050-9: IP69K *
Weight
(packed
state/only
sensor)
Pre-wired cable (2M) E3FA: Approx. 110 g/ Approx. 50 g, respectively,
E3FB: Approx. 175 g/ Approx. 65 g, respectively
E3FA: Approx. 60 g/ Approx. 50 g,
E3FB: Approx. 95 g/ Approx. 65 g
Connector E3FA: Approx. 30 g/ Approx. 10 g, respectively,
E3FB: Approx. 85 g/ Approx. 20 g, respectively
E3FA: Approx. 20 g/ Approx. 10 g,
E3FB: Approx. 50 g/ Approx. 20 g
Material
Case E3FA: ABS, E3FB: Nickel-brass
Lens and Display PMMA
Adjuster POM
Nut E3FA: POM, E3FB: Nickel-brass
Accessories Instruction sheet
M18 nuts (4 pcs)
Instruction sheet
M18 nuts (2 pcs)