For more Information
please call
1-800-Belden1
General Description:
20 AWG stranded (19x32) .037" tinned copper conductor, foam polyethylene insulation, Duobond® II
(100% coverage) plus an overall tinned copper braid shield (93% coverage), PVC jacket.
Usage (Overall)
Suitable Applications: Thin Ethernet
Physical Characteristics (Overall)
Conductor
AWG:
# Coax AWG Stranding Conductor Material Dia. (mm)
120 19x32 TC - Tinned Copper 0.9398
Total Number of Conductors: 1
Insulation
Insulation Material:
Insulation Material Dia. (mm)
FHDPE - Foam High Density Polyethylene 2.5908
Outer Shield
Outer Shield Material:
Layer # Outer Shield Trade Name Type Outer Shield Material Coverage (%)
1Bonded Duofoil® Tape Bonded Aluminum Foil-Polyester Tape-Aluminum Foil 100
2 Braid TC - Tinned Copper 93
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Overall Cable
Overall Nominal Diameter: 4.699 mm
Mechanical Characteristics (Overall)
Operating Temperature Range: -40°C To +80°C
UL Temperature Rating: 60°C (UL AWM Style 1354)
Bulk Cable Weight: 34.229 Kg/Km
Max. Recommended Pulling Tension: 200.169 N
Min. Bend Radius/Minor Axis: 50.800 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CL2, CM
CEC/C(UL) Specification: CM
AWM Specification: UL Style 1354 (30 V 60°C)
EU Directive 2011/65/EU (ROHS II): Yes
Page 1 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
9907 Coax - Coaxial Cable - Thinnet 10Base2 Ethernet
IEEE Specification: IEEE802.3 10Base2
Other Standards: ISO8802.3 10Base2
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Customer Part Number Reference Specification: DEC Part No. 17-01248-00
RG Type: 58A/U
Flame Test
UL Flame Test: UL1685 UL Loading
Plenum/Non-Plenum
Plenum (Y/N): No
Plenum Number: 82907, 89907
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm) Tolerance (Ohms)
50 +/- 2
Nom. Capacitance Conductor to Shield:
Capacitance (pF/m)
83.3374
Nominal Velocity of Propagation:
VP (%)
80
Nominal Delay:
Delay (ns/m)
4.16687
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
28.8728
Maximum Loop Resistance:
Resistance (Ohm/km)
50.0024
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/km)
19.0298
Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100m)
11.41083
10 4.2653
50 9.54771
100 13.7802
200 20.0141
400 29.2009
700 39.7001
Page 2 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
9907 Coax - Coaxial Cable - Thinnet 10Base2 Ethernet
900 45.6059
1000 48.5588
Max. Operating Voltage - UL:
Voltage Description
300 V RMS
30 V RMS UL AWM Style 1354
Notes (Overall)
Notes: Tape to bond at overlap area only. Tape is not designed to bond to dielectric core.
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
9907 E4XU1000 305 MT 10.886 KG GRAY, LIGHT DEC RG-58 TYPE COAX
9907 E4X1000 305 MT 11.340 KG GRAY, LIGHT DEC C RG-58 TYPE COAX
9907 E4X1640 500 MT 18.597 KG GRAY, LIGHT DEC C RG-58 TYPE COAX
9907 E4X2500 762 MT 28.350 KG GRAY, LIGHT DEC C RG-58 TYPE COAX
9907 E4X3280 1,000 MT 37.195 KG GRAY, LIGHT DEC C RG-58 TYPE COAX
9907 E4X500 152 MT 5.670 KG GRAY, LIGHT DEC RG-58 TYPE COAX
9907 E4X5000 1,524 MT 56.699 KG GRAY, LIGHT DEC RG-58 TYPE COAX
Notes:
C = CRATE REEL PUT-UP.
Revision Number: 2 Revision Date: 09-25-2012
© 2013 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
9907 Coax - Coaxial Cable - Thinnet 10Base2 Ethernet