CUSTOMER DRAWING
Raychem Molded Parts
305 Constitution Drive,
Menlo Park, CA 94025
TITLE:
CABLE BREAKOUT BOOT,
THREE ENTRY
Unless otherwise specified dimensions are in inches.
[Metric dimensions are shown in brackets DOCUMENT NO.: TXXX-XXXFR
REV: G
Tyco Electronics reserves the right to amend this drawing at any
time. Users should evaluate the suitability of the product for their
application. SCALE: None DATE: August 27, 2009
REVISED BY:
UNGUYEN CAGE CODE:
06090 Org. Date:
5/7/07 ECO #:
09-019755 FILE :
TXXX-XXXFR.doc SIZE
A SHEET: 1 of 1
© 2003-2009 Tyco Electronics Corporation. All rights reserved
If this document is printed it becomes uncontrolled. Check for the latest revision.
CABLE BREAKOUT BOOTS, THREE ENTRY
Table of Dimensions, inch (mm):
PART
NUMBER
(See Note*)
BODY ID
Exp. Rec’d.
(A), Min (B), Max
LEG ID
Exp. Rec’d.
(C), Min (D), Max
Length Recovered
Min
(E), Body (F), Leg
Rec’d. Wall
Thickness
Ref
(W)
T3-9FR 0.90 (23) 0.36 (9) 0.33 (8) 0.12 (3) 2.0 (51) 0.7 (18) 0.04 (1.0)
T14-23FR 1.20 (30) 0.69 (18) 0.50 (13) 0.18 (5) 2.3 (58) 1.0 (25) 0.09 (2.3)
T23-50FR 1.20 (30) 0.69 (18) 0.50 (13) 0.18 (5) 2.3 (58) 1.0 (25) 0.09 (2.3)
T42-100FR 1.70 (43) 0.90 (23) 0.82 (21) 0.30 (8) 2.3 (58) 1.2 (30) 0.12 (3.0)
T60-150FR 1.70 (43) 0.90 (23) 0.82 (21) 0.30 (8) 2.3 (58) 1.2 (30) 0.12 (3.0)
T150-300FR 2.40 (61) 1.40 (36) 1.25 (32) 0.50 (13) 3.5 (89) 1.6 (41) 0.12 (3.0)
T200-400FR 2.40 (61) 1.40 (36) 1.25 (32) 0.50 (13) 3.5 (89) 1.6 (41) 0.12 (3.0)
T-400FR 3.20 (81) 2.00 (51) 1.40 (36) 0.75 (19) 3.5 (89) 1.6 (41) 0.14 (3.6)
T500-600FR 4.90 (124) 2.32 (59) 2.00 (51) 1.00 (25) 7.5 (191) 2.2 (56) 0.12 (3.0)
Note*: Add “NA” to the end of Part Number if no adhesive is required
Material: Heat shrinkable boot material in accordance with –3 polyolefin
Factory applied sealant: Factory applied hot melt adhesive is standard.