ADCMP350–ADCMP357 Preliminary Technical Data
Rev. PrA | Page 2 of 4
SPECIFICATIONS
(VCC=Full Operating Range, TA=-40°C to +125°C, unless otherwise noted.)
Parameter Min Typ Max Units Test Conditions/Comments
SUPPLY
VCC Operating Voltage Range 2.25 3.6 V
VIN Operating Voltage Range 22 V
Supply Current 15 20 µA
INTERNAL REFERENCE
ADCMP350/2/4/6 0.585 0.6 0.615 V VCC=3.3V, TA=-40°C to +85°C
0.579 0.6 0.621 V VCC=3.3V, TA=-40°C to +125°C
ADCMP351/3/5/7 1.17 1.2 1.23 V VCC=3.3V, TA=-40°C to +85°C
1.158 1.2 1.242 V VCC=3.3V, TA=-40°C to +125°C
VIN HYSTERESIS 20 mV
INPUT BIAS CURRENT 10 nA VCC=3.3V
THRESHOLD TEMPERATURE COEFFICIENT 30 ppm/ºC
VIN TO OUT DELAY 2 µs VIN= VTH to (VIN-100mV)
OUT/OUT VOLTAGE LOW 0.3 V VIN<VTH min, ISINK=1.2mA
OUT/OUT VOLTAGE HIGH 0.8xVcc V VIN>VTH max, ISOURCE=500µA
OUT/OUT OPEN-DRAIN OUTPUT LEAKAGE CURRENT 1 µA
VCC>VTH, OUT/OUT=22V
ABSOLUTE MAXIMUM RATINGS
Table 3. TA = 25°C unless otherwise noted.
Parameter Rating
VCC -0.3V to +6V
VIN -0.3V to +25V
OUT, OUT (Open-Drain) -0.3V to +25V
OUT, OUT (Push-Pull) -0.3V to +6V
Operating Temperature Range -40°C to +125°C
Storage Temperature Range -65°C to +150°C
θJA Thermal Impedance, SC70 146°C/W
Lead Temperature
Soldering (10 sec) 300°C
Vapour Phase (60 sec) 215°C
Infrared (15 sec) 220°C
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only and functional operation of the device at these or
any other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.