Safety Relay G7SA Slim Safety Relays Conforming to EN Standards The forcibly guided contact in the G7SA assures safe operation (EN50205 Class A, approved by VDE.) Ideal for use in safety circuits in press machinery, machine tools, and other production machinery. Four-pole and six-pole Relays are available. The Relay's terminal arrangement simplifies PWB pattern design. Reinforced insulation between inputs and outputs. Reinforced insulation between some poles. X VDE UL, CSA approval pending. CE marking. Note: Be sure to refer to the Precautions on page 6. Ordering Information Safety Relays Type Sealing Standard S a da d Flux-tight u g Poles 4 poles o es 6 poles o es Contacts 3PST-NO, SPST-NC Rated voltage 24 VDC C Model G7SA-3A1B DPST-NO, DPST-NC G7SA-2A2B 5PST-NO, SPST-NC G7SA-5A1B 4PST-NO, DPST-NC G7SA-4A2B 3PST-NO, 3PST-NC G7SA-3A3B Safety Relay Sockets Type Track-mounting ac ou g Track ac mounting ou ga and d sc screw e mounting ou g possible oss b e LED indicator No o Yes es Back-mounting ac ou g PCB C terminals e as No o Poles Model 4 poles P7SA-10F 6 poles P7SA-14F 4 poles P7SA-10F-ND 6 poles P7SA-14F-ND 4 poles P7SA-10P 6 poles P7SA-14P Model Number Legend G7SA-jAjB 1 2 1. NO Contact Poles 2: DPST-NO 3: 3PST-NO 4: 4PST-NO 5: 5PST-NO 2. NC Contact Poles 1: SPST-NC 2: DPST-NC 3: 3PST-NC 1 G7SA G7SA Specifications Ratings Coil Rated voltage 24 VDC Note: Rated current Coil resistance 4 poles: 15 mA 6 poles: 20.8 mA 4 poles: 1,600 6 poles: 1,152 Must-operate voltage 75% max. (V) Must-release voltage 10% min. (V) Max. voltage 110% (V) Power consumption 4 poles: Approx. 360 mW 6 poles: Approx. 500 mW 1. The rated current and coil resistance are measured at a coil temperature of 23C with tolerances of 15%. 2. Performance characteristics are based on a coil temperature of 23C. 3. The value given for the maximum voltage is for voltages applied instantaneously to the Relay coil (at an ambient temperature of 23C) and not continuously. Contacts Resistive load (cos =1) Load Rated load 6 A at 250 VAC, 6 A at 30 VDC Rated carry current 6A Max. switching voltage 250 VAC, 125 VDC Max. switching current 6A Characteristics Safety Relay Sockets Model P7SA-14j Note: Continuous current 6A Dielectric strength 2,500 VAC for 1 min. between poles Insulation resistance 100 M min. (see note) Measurement conditions: Measurement of the same points as for the dielectric strength at 500 VDC. Safety Relays Contact resistance 100 m max. (The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method.) Operating time (see note 2) 20 ms max. Response time (see note 2) 10 ms max. (The response time is the time it takes for the normally open contacts to open after the coil voltage is turned OFF.) Release time (see note 2) 20 ms max. Maximum operating a u ope a g f frequency Mechanical 36,000 operations/hr Rated load 1,800 operations/hr Insulation resistance 100 M min. (at 500 VDC) (The insulation resistance was measured with a 500-VDC megger at the same places that the dielectric strength was measured.) Dielectric strength (see notes 3, 4) Between coil contacts/different poles: 4,000 VAC, 50/60 Hz for 1 min (2,500 VAC between poles 3-4 in 4-pole Relays or poles 3-5, 4-6, and 5-6 in 6-pole Relays.) Between contacts of same polarity: 1,500 VAC, 50/60 Hz for 1 min Vibration resistance Shock S oc resistance es s a ce Life e expectancy e pec a cy 10 to 55 Hz, 1.5-mm double amplitude Destruction 1,000 m/s2 Malfunction 100 m/s2 Mechanical 10,000,000 operations min. (at approx. 36,000 operations/hr) Electrical 100,000 operations min. (at the rated load and approx. 1,800 operations/hr) Error rate (see note 5)(P level) (reference value) 1 mA at 5 VDC Ambient temperature (see note 6) Operating: -40C to 85C (with no icing or condensation) Storage: -40C to 85C (with no icing or condensation) Ambient humidity Operating: 35% to 85% Storage: 35% to 85% Weight 4 poles: Approx. 22 g 6 poles: Approx. 25 g Approved standards (see note 7) EN61810-1 (IEC61810-1), EN50205, UL508, CSA22.2 No. 14 Note: 1. The values listed above are initial values. 2. These times were measured at the rated voltage and an ambient temperature of 23C. Contact bounce time is not included. 3. Pole 3 refers to terminals 31-32 or 33-34, pole 4 refers to terminals 43-44, pole 5 refers to terminals 53-54, and pole 6 refers to terminals 63-64. 2 G7SA G7SA 4. When using a P7SA Socket, the dielectric strength between coil contacts/different poles is 2,500 VAC, 50/60 Hz for 1 min. 5. This error rate is for a switching frequency of 300 operations/min. 6. When operating at a temperature between 70C and 85C, reduce the rated carry current (6 A at 70C or less) by 0.1 A for each degree above 70C. 7. US and CSA approval is pending. Dimensions Note: All units are in millimeters unless otherwise indicated. The diagrams are drawn in perspective. Safety Relays Terminal Arrangement/ Internal Connection Diagram (Bottom View) G7SA-3A1B G7SA-3A1B G7SA-2A2B 13 max. Printed Circuit Board Design Diagram (Bottom View) 40 max. Ten, 1.4 dia. 24 max. 0.5 1 0.5 3.5 G7SA-2A2B Terminal Arrangement/ Internal Connection Diagram (Bottom View) G7SA-5A1B G7SA-5A1B G7SA-4A2B G7SA-3A3B Printed Circuit Board Design Diagram (Bottom View) 13 max. 50 max. Fourteen, 1.4 dia. 24 max. G7SA-4A2B 0.5 0.5 1 3.5 G7SA-3A3B 3 G7SA G7SA Safety Relay Sockets Terminal Installation/Internal Connection Diagram (Top View) P7SA-10F, P7SA-10F-ND Track-mounting Socket 22.5 max. G7SA-3A1B Mounted G7SA-2A2B Mounted 60.5 max. Ten, M3 9 max. Mounting Hole Placement Diagram (Top View) Two, 4 dia. or M3.5 72 max. LED indicator 9 max. Note: 4 dia. The socket is shown with the finger cover removed. Note: Only the -ND Sockets have LED indicators. P7SA-14F, P7SA-14F-ND Track-mounting Socket 30 max. Fourteen, M3 Terminal Arrangement/Internal Connection Diagram (Top View) G7SA-5A1B G7SA-4A2B G7SA-3A3B Mounted Mounted Mounted 60.5 max. 9 max. Mounting Hole Placement Diagram (Top View) Two, 4 dia. or M3.5 72 max. LED indicator 9 max. 4 dia. Note: The socket is shown with the finger cover removed. Note: 4 Only the -ND Sockets have LED indicators. G7SA G7SA P7SA-10P Back-mounting Socket (for PCB) 50 max. Terminal Arrangement/Internal Mounting Hole Placement (Bottom View) Connection Diagram (Bottom View) 15 max. G7SA-3A1B Mounted Three, 3.2 dia. (for M3 tapping screws) 41.5 max. 10.160.1 G7SA-2A2B Mounted Ten, 1.1 dia. Three, 2.6 dia. (for M3 tapping screws) P7SA-14P Back-mounting Socket (for PCB) Terminal Arrangement/Internal Connection Diagram (Bottom View) 60 max. 15 max. Mounting Hole Placement (Bottom View) G7SA-5A1B Mounted 41.5 max. G7SA-4A2B Mounted Three, 3.2 dia. (for M3 tapping screws) Three, 2.6 dia. (for M3 tapping screws) G7SA-3A3B Mounted 5 G7SA Precautions Safety Relays A Safety Relay is a Relay with which a safety circuit can be configured. Wiring Use one of the following wires to connect to the P7SA-10F/10FND/14F/14F-ND. Stranded wire: 0.75 to 1.5 mm2 Solid wire: 1.0 to 1.5 mm2 Tighten each screw of the P7SA-10F/10F-ND/14F/14F-ND to a torque of 0.98 N S m securely. Wire the terminals correctly with no mistakes in coil polarity, otherwise the G7SA will not operate. Cleaning The G7SA is not of enclosed construction. Therefore, do not wash the G7SA with water or detergent. Forcibly Guided Contacts (from EN50205) If an NO contact becomes welded, all NC contacts will maintain a minimum distance of 0.5 mm when the coil is not energized. Likewise if an NC contact becomes welded, all NO contacts will maintain a minimum distance of 0.5 mm when the coil is energized. 6 G7SA G7SA G7SA 7 G7SA G7SA ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. J120-E1-1 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company Industrial Devices and Components Division H.Q. Industrial Control Components Division 28th Fl., Crystal Tower Bldg., 1-2-27, Shiromi, Chuo-ku, Osaka 540-6028 Japan Tel: (81)6-6949-6025/Fax: (81)6-6949-6029 8 Printed in Japan 0200-2M (0200) a