Surge Arrester EM3000XB
2-Electrode-Arrester Ordering code: B88069X6140B502
AB E / AB PM Issue 01, 10.07.2003
Page 1 of 2
DC spark-over voltage 1) 2)
3000
± 20
V
%
Impulse spark-over voltage
at 100 V/µs - for 99 % of measured values
- typical values of distribution
at 1 kV/µs - for 99 % of measured values
- typical values of distribution
< 4200
< 3800
< 5000
< 4200
V
V
V
V
Service life 3)
3 operations 8/20 µs 2 kA
300 operations 8/20 µs 100 A
10 operations 50 Hz; 1 s 1 A
Insulation resistance at 100 Vdc > 1 GΩ
Capacitance at 1 MHz < 1 pF
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
~ 15
< 1
~ 80
V
A
V
Weight ~ 1 g
Operation and storage temperature -40 ... +90 °C
Climatic category (IEC 60068-1) 40/ 90/ 21
Marking, red
EM 3000 YY O
EM - Series
3000 - Nominal voltage
YY - Year of production
O - Non radioactive
1) At delivery AQL 0.65 level II, DIN ISO 2859
2) In ionized mode
3) Arrester has to meet: Voltage withstand test AC 1500 V, 1min
Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845