TM CNXTM Series Wireless System: CNX 3000 Wireless Multimeter Fluke CNX enabled Thermal Imagers NO MORE run around * See multiple measurements on one screen at one time * View and analyze readings from 10 wireless modules at once on a PC with the CNX PC 3000 PC adapter * Set up the modules and take the readings from up to 20 meters away * Capture up to five remote measurements wirelessly with each thermal image NO MORE writing down * With the CNX PC adapter, capture up to 65,000 sets of min/max/avg readings (not valid for the thermal imager) NO MORE waiting around * Save time and money by taking multiple measurements simultaneously * Isolate intermittent events without even being there, using the modules' log function (with CNX 3000 multimeter or CNX PC 3000 PC adapter) NO MORE uncomfortable positions * Set up the measurement once; read it when you want, from where you want * Increase safety by taking readings in a separate location from the point of measurement * Fluke CNX 3000 multimeter and CNX wireless modules meet measurement CAT III 1000 V and CAT IV 600 V safety standards CNX v3000 AC Voltage Module Model CNX a3000 AC Current Clamp Module CNX i3000 iFlex AC Current Clamp Module TM CNX t3000 K-type Temperature Module CNX PC300 PC Adapter Description Kits (Buy a system or kit and save) FLK-CNX 3000 Multimeter, three iFlex Clamp Modules, one Voltage Module and accessories Industrial System FLK-CNX 3000 General Multimeter, iFlex Clamp Module, AC Voltage Module and accessories Maintenance System FLK-CNX 3000 Multimeter, AC Current Clamp Module, Temperature Module and accessories HVAC System TM TM FLK-CNX t3000 Kit Multimeter, Temperature Module and accessories FLK-CNX i3000 Kit Multimeter, iFlex Clamp Module and accessories FLK-CNX a3000 Kit Multimeter, AC Current Clamp Module and accessories FLK-CNX v3000 Kit Multimeter, AC Voltage Module and accessories FLK-Ti125/C3i 30Hz Industrial-Commercial Thermal Imager 30 Hz with 3 CNX-i3000 FLK-Ti125/C3i 9Hz Industrial-Commercial Thermal Imager 9 Hz with 3 CNX-i3000 (not available in US or Canada) General Purpose Thermal Imager 9 Hz with 1 CNX-a3000 FLK-Ti100/C1a 9Hz CNX main units FLK-CNX 3000 Wireless Multimeter FLK-TI1XX Series Thermal Imagers CNX modules FLK-CNX i3000 iFlex AC Current Clamp Module FLK-CNX a3000 AC Current Clamp Module FLK-CNX v3000 AC Voltage Module FLK-CNX t3000 K-type Temperature Module PC adapter FLK-CNX PC3000 PC Adapter TM Wireless Multimeter and accessories See www.fluke.com/thermography for a complete list of wireless thermal imager models FLK-CNX 3000 Series iFlex Module and accessories TM FLK-CNX 3000 Series AC Current Clamp Module FLK-CNX 3000 Series AC Voltage Module and accessories FLK-CNX 3000 Series K-type Temperature Module and accessories Allows for wireless transfer of logged data or thermal images into pc software (not valid for the thermal imager) Your Fluke Ti1XX thermal imager can be upgraded FREE to enable its CNX wireless capabilities. Connect your thermal imager to your PC with the included USB cable. Open SmartView software and update to the most current version. Then select Enable CNXTM. (R) Note: Upgrade is not available in all countries at this time. For more details about the Fluke CNX wireless team go to www.fluke.com/cnx. Fluke. The Most Trusted Tools in the World. Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com Modification of this document is not permitted without written permission from Fluke Corporation. (c)2012-2013 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 9/2013 4235335F_EN Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A. FLUKE CNX TM WIRELESS TEAM. YOUR TOOLS...CONNECTED! A suite of tools that connect together wirelessly to make your job easier. You solve problems faster. You troubleshoot quicker. That's revolutionary. That's Fluke. Wireless modules The team. Fluke CNX tools work together. Remotely. Simultaneously. Conveniently. Wireless multimeter or thermal imager The captains. Displays multiple readings in real time, at the same time, on one screen. Fluke software The statistician. CNXTM software and SmartView software, depending on which captain you are using, both easily transfer the measurements captured wirelessly to your computer for analysis and reports. (R) Meet the Fluke CNX Wireless Team. TM TM YOUR TOOLS--CONNECTED. TAKE READINGS QUICKER. SOLVE PROBLEMS FASTER. Fluke CNX wireless test tools work together to help you solve problems faster. With the CNX team, measurements are: * Remote * Simultaneous * Recordable The new Fluke wireless troubleshooting team lets you see live measurements from multiple modules simultaneously and remotely on a single screen or infrared image. The wireless multimeter displays readings from up to three wireless modules, plus the meter. The laptop displays readings from up to 10 modules in the CNX sw3000 software. The wireless thermal imagers display measurements from up to five wireless modules within the thermal image. Download your image with the wireless captured measurements into SmartView software and create thorough, professional reports for clients or management. Wireless enabled modules measure ac voltage, temperature and ac current. Choose a standard true-rms clamp or flexible true-rms clamp to measure ac current. Mix and match modules to suit your unique measurement needs. (R) WIRELESS TOOLS The team. Fluke CNX tools work together. Remotely. Simultaneously. Conveniently. Possible applications Detecting power interruption-- Detecting power interruption - measurement procedures Single measurement Troubleshoot measurement procedures Utility power lines Utility transformer bank Ungrounded (hot) conductors Grounded neutral conductor N A B C 208 V, 3 circuit Auto L2 V AC 207.4 .2 1 2 205 205.2 208 V, 1 circuit V AC V AC 120/208 V, 1 circuit L1 120 V 120 V N N 208 V B 208 V C A N CAT CAT CAT CAT 600 600 600 V 600 CAT V CAT CAT VV CAT 300 300 300 V 300 VV V 120 V, 1 circuit 120 V N 208 V 120/208 V, 3 circuit Neutral busbar These illustrations demonstrate a few different ways the CNX system can be used. www.fluke.com/cnx A to N B to N C to N Single-Pole (SP) or 1-Pole 115 V, 1 general-purpose circuits ON F OF A to B B to C C to A ON ON ON F OF F A to B to C OF Double-Pole (DP) or 2-Pole 208 V, 1 lighting and power circuits Double-Pole (3P) or 3-Pole 208 V, 3 circuits F OF WIRELESS MULTIMETER OR THERMAL IMAGER SOFTWARE The statistician. CNXTM sw3000 software: Transfer recorded data to your computer, and easily create analyses and reports. SmartView software: Create thorough, professional reports for clients and management. The captains. Get multiple readings in real time, at the same time, on one screen. From up to 20 meters away. phase tting procedures systems (R) Determining current unbalance Measure incoming current Measuring current load Determining current unbalance L1 Motor power cabinet L2 L3 INRUSH INRUSH Hz Hz INRUSH Hz INRUSH Hz CAT CAT 600 600 CAT VV CAT 300 300 VV OR CAT V 600 CAT V 300 OR Auto V AC OR L1 L2 L3 1 2 3 0.0 68.6 71.5 51.2 A AC A AC A AC Auto V AC 1 2 3 0.0 27.9 191.2 15.6 A AC V AC A AC Auto V AC Note: Use a wireless multimeter or a thermal imager. Both tools can not be used simultaneously to receive wireless measurements. 1 2 3 0.0 46.7 50.1 29.4 A AC A AC A AC Note: Use a wireless multimeter or a thermal imager. Both tools can not be used simultaneously to receive wireless measurements. Note: Use a wireless multimeter or a thermal imager. Both tools can not be used simultaneously to receive wireless measurements. Note: Use a wireless multimeter or a thermal imager. Both tools can not b e used simultaneously to receive w ireless measurements.