MCC Features * * * * MB05S !"# $ % !"# THRU MB10S 0.5Amp Single Phase Glass Passivated Bridge Rectifier 50 to 1000 Volts Surface Mount Package Glass Passivated Diode Construction Moisture Resistant Epoxy Case High Surge Current Capability Maximum Ratings * * MBS -1 Operating Temperature: -55C to +150C Storage Temperature: -55C to +150C MCC Catalog Number Device Marking MB05S MB1S MB2S MB4S MB6S MB8S MB10S MB05S MB1S MB2S MB4S MB6S MB8S MB10S Maximum Rccurrent Peak Reverse Voltage 50V 100V 200V 400V 600V 800V 1000V Maximum RMS Voltage 35V 70V 140V 280V 420V 560V 700V Maximum DC Blocking Voltage 50V 100V 200V 400V 600V 800V 1000V Electrical Characteristics @ 25C Unless Otherwise Specified Average Forward IF(AV) 0.5A Note1 TA = 30C Note2 TA = 30C 0.8A Current Peak Forward Surge IFSM 30A 8.3ms, half sine Current Maximum 1.0V IFM = 0.5A; Instantaneous VF Forward Voltage TA = 25C Maximum DC Reverse Current At IR 5 A TA = 25C Rated DC Blocking Voltage Typical Junction CJ 25pF Measured at Capacitance 1.0MHz, VR=4.0V Note1. Measured at 1.0 MHz and applied reverse voltage of 4.0 Volts Note2. On alum: substrate P.C.B with an rea of 0.8 x 0.8 x 0.25" ( 20 x 20 x 6.4mm ) mounte on 0.05 x 0.05 "( 13 x 13 mm ) solder pad. *Pulse Test: Pulse Width 300sec, Duty Cycle 1% D B E + F C A Notch in case K M J G H N L M .252 .017 .090 .004 .021 .055 ---- .040 .008 www.mccsemi.com .272 .029 .106 .008 .023 .065 .200 .050 .014 6.40 0.45 2.30 0.10 0.53 1.40 ---- 1.02 0.15 6.91 0.75 2.70 0.20 0.58 1.65 5.08 1.27 0.35 MCC MB05S thru MB10S Figure 1 Typical Forward Characteristics Figure 2 Typical Reverse Characteristics 20 100 60 10 40 6 20 4 10 2 6 25C Amps 1 4 .6 2 .4 Amps 1 .6 .2 .4 .1 .2 .06 .04 .06 .04 .02 .01 TA=25C .1 .02 .4 .6 .8 1.0 1.2 1.4 .01 20 Volts 40 60 Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts 80 100 120 140 Volts Instantaneous Reverse Leakage Current - MicroAmperesversus Percent Of Rated Peak Reverse Voltage - Volts Figure 3 Forward Derating Curve Figure 4 Peak Forward Surge Current 1.2 60 1.0 50 40 .8 30 .6 Amps Amps .4 10 5 0 .2 Single Phase, Half Wave 60Hz Resistive or Inductive Load 0 20 0 40 50 75 100 125 1 2 4 6 8 10 20 40 60 80 100 Cycles 150 C 175 Peak Forward Surge Current - Amperesversus Number Of Cycles At 60Hz - Cycles Average Forward Rectified Current - Amperesversus Ambient Temperature - C www.mccsemi.com