PMH Panel Mount Pow er Supply
24V 100W 1
Phase
/ PMH-24V100WCA
□
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (December 2014, Rev. 01)
Reliability Data
MTBF > 700,000 hrs. as per Telcordia SR-332
I/P: 115Vac, O/P: 100% load, Ta: 25°C
10 years (115Vac & 230Vac, 50% load @ 40°C)
Safety Standards / Directives
Electrical Safety SIQ Bauart
UL/cUL recognized
CB scheme
EN 60950-1, EN 60335-1, EN 61558-1, EN 61558-2-16
UL 60950-1 and CSA C22.2 No. 60950-1 (File No.
E191395)
IEC 60950-1, IEC 60335-1, IEC 61558-1,
IEC 61558-2-16
CE In conformance with EMC Directive 2004/108/EC and
Low Voltage Directive 2006/95/EC
Material and Parts RoHS Directive 2011/65/EU Compliant
Galvanic Isolation Input to Output 4.2KVac
Input to Ground 1.5KVac
EMC
EMC / Emissions CISPR 22, EN 55022, FCC Title 47: Class B,
EN 55014-1, EN 61000-6-3
Immunity to EN 55024, EN 61000-6-1, EN 55014-2
Electrostatic Discharge IEC 61000-4-2 Level 4 Criteria A1)
Air Discharge: 15kV
Contact Discharge: 8kV
Radiated Field IEC 61000-4-3 Level 3 Criteria A
80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation
1.4GHz-2GHz, 10V/M with 1kHz tone / 80% modulation
2GHz-
2.7GHz, 10V/M with 1kHz tone / 80% modulation
Electrical Fast Transient / Burst IEC 61000-4-4 Level 3 Criteria A1)
2kV
Surge IEC 61000-4-5 Level 3 Criteria A1)
Common Mode2): 2kV
Differential Mode3): 1kV
Conducted IEC 61000-4-6 Level 3 Criteria A
150kHz-80MHz, 10Vrms
Power Frequency Magnetic Fields IEC 61000-4-8 Criteria A
10A/Meter
Voltage Dips IEC 61000-4-11 100% dip; 1 cycle (20ms); Self Recoverable
Low Energy Pulse Test (Ring Wave) IEC 61000-4-12 Level 3 Criteria A
Common Mode2): 2kV
Differential Mode3): 1kV
Harmonic Current Emission IEC/EN 61000-3-2, Class A
Voltage Fluctuation and Flicker
1) Criteria A: Normal performance within the specification limits
2) Asymmetrical: Common mode (Line to earth)