TECHNICAL DATASHEET
PMH Panel Mount Pow er Supply
24V 100W 1
Phase
/ PMH-24V100WCA
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (December 2014, Rev. 01)
1
PMH
Highlights & Features
Universal AC input voltage
Power will not de-rate for the entire input voltage range
Full corrosion resistant aluminium casing
No load power consumption < 0.5W
High MTBF > 700,000 hrs as per Telcordia SR-332
Designed for household appliances to IEC/EN 60335-1,
IEC/EN 61558-1 and IEC/EN 61558-2-16
Versatile connector options available: IP20, Front Face and
Harness connectors
Safety Standards
CB Certified for worldwide use
Model Number : PMH-24V100WCA
Unit Weight: 0.43 kg
Dimensions (H x W x D): 158 x 97 x 38 mm
General Description
The PMH-24V100WCA offers universal input from 85Vac to 264Vac with nominal output voltage of 24V. The highly efficient
convection cooling construction can operates from -20°C to 70°C. The PMH series is specifically designed for household electrical
appliances with safety approvals including IEC/EN 60335-1 and IEC/EN 61558-2-16. In addition the product meets the EMC approvals
to EN 55014-1 and EN 55014-2 for household appliances without extra EMI filter required.
Model Information
PMH Panel Mount Power Supply
Model
Number
Input Voltage Range Output
V
oltage
Output Curr
ent
PMH-24V100WCA 85-264Vac (120-375Vdc) 24Vdc 4.16A
Model Number ing
PM
H –
24V
100W
C
A
Panel Mount Product Type
H – Household
Series
Output Voltage Output Power Package Type
C Enclosed
No PFC Connector Type
A – Terminal Block
J IP20 Connector*
L Front Face*
H Harness*
*Options
TECHNICAL DATASHEET
PMH Panel Mount Pow er Supply
24V 100W 1
Phase
/ PMH-24V100WCA
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (December 2014, Rev. 01)
2
Specifications
Input Ratings / Characteristics
Nominal Input Voltage 100-240Vac
Input Voltage Range 85-264Vac
Nominal Input Frequency 50-60Hz
Input Frequency Range 47-63Hz
Nominal DC Input Voltage 125-250Vdc
DC Input Voltage Range 120-375Vdc
Input Current < 2.00A @ 115Vac, < 1.10A @ 230Vac
Efficiency at 100% Load > 87.0% @ 115Vac, > 89.0% @ 230Vac
Max Power Dissipation < 0.5W @ 115Vac & 230Vac (0% load)
Max Inrush Current < 60A @ 115Vac, < 120A @ 230Vac
Leakage Current < 1mA @ 240Vac
Output Ratings / Characteristics
Nominal Output Voltage 24Vdc
Output Voltage Tolerance ± 2% (initial set point tolerance from factory)
Output Voltage Adjustment Range 22-28Vdc
Output Current 4.16A
Output Power 100W
Line Regulation < 0.5% typ. (@ 85-264Vac input, 100% load)
Load Regulation < 1% typ. (@ 85-264Vac input, 0-100% load)
PARD (20MHz) < 100mVpp
Rise Time
< 30ms @ nominal input (100% load)
Start-up Time < 2500ms @ nominal input (100% load)
> 15ms @ 115Vac, > 100ms @ 230Vac (100% load)
Dynamic Response (Overshoot & Undershoot O/P Voltage) ± 5% @ 0-100% load
Start-up with Capacitive Loads 8,000µF Max
TECHNICAL DATASHEET
PMH Panel Mount Pow er Supply
24V 100W 1
Phase
/ PMH-24V100WCA
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (December 2014, Rev. 01)
3
Mechanical
Case Chassis / Cover
Aluminium
Dimensions (L x W x D) 158 x 97 x 38 mm
Unit Weight 0.43 kg
Indicator Green LED (DC OK)
Cooling System Convection
Terminal PMH-24V100WCAA M3.5 x 7 Pins (Rated 300V/15A)
PMH-24V100WCAJ M3.5 x 7 Pins (Rated 300V/20A)
PMH-24V100WCAL M3.5 x 7 Pins (Rated 300V/20A)
PMH-24V100WCAH Input: B3P(6-2.3.5)-VH(LF)(SN)
Output: B4P7-VH(LF)(SN)
Wire PMH-24V100WCAA
AWG 20-14
PMH-24V100WCAJ
AWG 20-12
PMH-24V100WCAL
Sound Pressure Level (SPL) < 40dBA
Environment
Surrounding Air Temperature Operating -20°C to +70°C
Storage -25°C to +85°C
Power De-rating > 50°C de-rate power by 2.5% / °C
Operating Humidity 5 to 95% RH (Non-Condensing)
Operating Altitude 0 to 5,000 Meters
Shock Test (Non-Operating) IEC 60068-2-27, 30G (300m/S²) for a duration of
18ms,1 times per direction, 2 times in total
Vibration (Non-Operating) IEC 60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak);
20 min per axis for all X, Y, Z direction
Pollution Degree 2
Protections
Overvoltage 28.8-35.2V, SELV Output, Hiccup Mode,
Non-Latching (Auto-Recovery)
Overload / Overcurrent > 120% of rated load current, Hiccup Mode,
Non-Latching (Auto recovery)
Over Temperature < 75°C Surrounding Air Temperature @ 100% load,
Non-Latching (Auto-recovery)
Short Circuit Hiccup Mode, Non-Latching
(Auto-recovery when the fault is removed).
Protection Against Shock Class I with PE* connection
*PE: Primary Earth
TECHNICAL DATASHEET
PMH Panel Mount Pow er Supply
24V 100W 1
Phase
/ PMH-24V100WCA
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (December 2014, Rev. 01)
4
Reliability Data
MTBF > 700,000 hrs. as per Telcordia SR-332
I/P: 115Vac, O/P: 100% load, Ta: 25°C
Expected Cap Life Time
10 years (115Vac & 230Vac, 50% load @ 40°C)
Safety Standards / Directives
Electrical Safety SIQ Bauart
UL/cUL recognized
CB scheme
EN 60950-1, EN 60335-1, EN 61558-1, EN 61558-2-16
UL 60950-1 and CSA C22.2 No. 60950-1 (File No.
E191395)
IEC 60950-1, IEC 60335-1, IEC 61558-1,
IEC 61558-2-16
CE In conformance with EMC Directive 2004/108/EC and
Low Voltage Directive 2006/95/EC
Material and Parts RoHS Directive 2011/65/EU Compliant
Galvanic Isolation Input to Output 4.2KVac
Input to Ground 1.5KVac
EMC
EMC / Emissions CISPR 22, EN 55022, FCC Title 47: Class B,
EN 55014-1, EN 61000-6-3
Immunity to EN 55024, EN 61000-6-1, EN 55014-2
Electrostatic Discharge IEC 61000-4-2 Level 4 Criteria A1)
Air Discharge: 15kV
Contact Discharge: 8kV
Radiated Field IEC 61000-4-3 Level 3 Criteria A
1)
80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation
1.4GHz-2GHz, 10V/M with 1kHz tone / 80% modulation
2GHz-
2.7GHz, 10V/M with 1kHz tone / 80% modulation
Electrical Fast Transient / Burst IEC 61000-4-4 Level 3 Criteria A1)
2kV
Surge IEC 61000-4-5 Level 3 Criteria A1)
Common Mode2): 2kV
Differential Mode3): 1kV
Conducted IEC 61000-4-6 Level 3 Criteria A
1)
150kHz-80MHz, 10Vrms
Power Frequency Magnetic Fields IEC 61000-4-8 Criteria A
1)
10A/Meter
Voltage Dips IEC 61000-4-11 100% dip; 1 cycle (20ms); Self Recoverable
Low Energy Pulse Test (Ring Wave) IEC 61000-4-12 Level 3 Criteria A
1)
Common Mode2): 2kV
Differential Mode3): 1kV
Harmonic Current Emission IEC/EN 61000-3-2, Class A
Voltage Fluctuation and Flicker
IEC/EN 61000-3-3
1) Criteria A: Normal performance within the specification limits
2) Asymmetrical: Common mode (Line to earth)
3) Symmetrical: Differential mode (Line to line)
TECHNICAL DATASHEET
PMH Panel Mount Pow er Supply
24V 100W 1
Phase
/ PMH-24V100WCA
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (December 2014, Rev. 01)
5
Block Diagram
Device Descriptions
1) Input & Output terminal block connector
2) DC voltage adjustment potentiometer (22V – 28V)
3) DC OK control LED (Green)
PMH-24V100WCAL: Front Face
PMH-24V100WCAA: Terminal Block
PMH-24V100WCAJ: IP20 Terminal Block
PMH-24V100WCAH: Harness
TECHNICAL DATASHEET
PMH Panel Mount Pow er Supply
24V 100W 1
Phase
/ PMH-24V100WCA
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (December 2014, Rev. 01)
6
Dimensions
L x W x D: 158 x 97 x 38 mm (PMH-24V100WCAA: Terminal Block)
Engineering Data
De-rating
Fig. 1 De-rating for Vertical and Horizontal Mounting Orientation
> 50°C de-rate power by 2.5% / °C
Note
1. Power supply components may degrade, or
be
damaged, when the power supply is
continuously used outside the shaded region,
refer to the graph shown in Fig. 1.
2. If the output capacity is not reduced when
surrounding air temperature >50°
C, the
device will run into Over Temperature
Protection. When acti
vated, the output
voltage will go into bouncing mode and will
recover when the surrounding air
temperature is lowered or the load is reduced
as far as necessary to keep the device in
working condition.
3.
In order for the device to function in the
manner intended, it is also necessary to keep
a safety distance of 20mm with adjacent units
while the device is in operation.
4.
Depending on the surrounding air
temperature and output load delivered by the
power supply, the device can be very hot!
5. If the device has to be mounted in any other
orientation, please do not hesitate to contact
info@deltapsu.com for more details.
TECHNICAL DATASHEET
PMH Panel Mount Pow er Supply
24V 100W 1
Phase
/ PMH-24V100WCA
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (December 2014, Rev. 01)
7
Output De-rating VS. AC Input Voltage
Assembly & Installation
Mounting holes for power supply assembly onto the mounting surface.
The power supply shall be mounted on minimum 2 mounting holes using M3 screw minimum 5mm length.
This surface belongs to customer’s end system or panel where the power supply is mounted.
Connector
Fig. 2 Mounting Orientation
Use flexible cable (stranded or solid) with the following sizes:
PMH-24V100WCAA
PMH-24V100WCAJ
PMH-24V100WCAL
AWG 20-14 AWG 20-12 AWG 20-12
The torque at the Connector shall not exceed 13Kgf.cm. The insulation stripping length should not exceed 0.275” or 7mm.
No output power de-rating across the entire
input voltage range
Side Mounting (Vertical)
Base Mounting (Vertical)
Side Mounting (Horizontal)
TECHNICAL DATASHEET
PMH Panel Mount Pow er Supply
24V 100W 1
Phase
/ PMH-24V100WCA
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (December 2014, Rev. 01)
8
Installation of Mounting Accessories
Safety Instructions
To ensure sufficient convection cooling, always maintain a safety distance of 20mm from all ventilated surfaces while the device
is in operation.
The device is not recommended to be placed on low thermal conductive surface, for example, plastics.
Note that the enclosure of the device can become very hot depending on the ambient temperature and load of the power supply.
Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning!
Do not touch the terminals while power is being supplied. Risk of electric shock.
Prevent any foreign metal, particles or conductors from entering the device through the openings during installation. It may cause:
Electric shock; Safety Hazard; Fire; Product failure
The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or instruction.
Warning: When connecting the device, secure Earth connection before connecting L and N. When disconnecting the device,
remove L and N connections before removing the Earth connection.
The device is earthed and must be inaccessible.
Only use M3 screw 6mm through the base mounting holes. This is to keep
a safety distance between the screw and internal components.
Recommended mounting tightening torque: 4~8Kgf.cm.
TECHNICAL DATASHEET
PMH Panel Mount Pow er Supply
24V 100W 1
Phase
/ PMH-24V100WCA
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (December 2014, Rev. 01)
9
Functions
Start-up Time
The time required for the output voltage to reach 90% of its set value, after the input voltage is applied.
Rise Time
The time required for the output voltage to change from 10% to 90% of its set value.
Hold-up Time
Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time
required for the output to reach 95% of its set value, after the input voltage is removed.
Graph illustrating the Start-up Time, Rise Time, and Hold-up Time
Inrush Current
Inrush current is the peak, instantaneous, input current
measured and, occurs when the input voltage is first applied.
For AC input voltages, the maximum peak value of inrush
current will occur during the first half cycle of the applied AC
voltage. This peak value decreases exponentially during
subsequent cycles of AC voltage.
Dynamic Response
The power supply output voltage will remains within ±5% of its
steady state value, when subjected to a dynamic load from 0%
to 100% of its rated current.
TECHNICAL DATASHEET
PMH Panel Mount Pow er Supply
24V 100W 1
Phase
/ PMH-24V100WCA
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (December 2014, Rev. 01)
10
Overload & Overcurrent Protections
The power supply’s Overload (OLP) and Overcurrent (OCP)
Protections will be activated when output current exceeds 120%
of IO (Max load). In such occurrence, the VO will start to droop and
once the power supply has reached its maximum power limit, the
protection is activated and the power supply will go into “Hiccup
mode” (Auto-Recovery). The power supply will recover once the
fault condition of the OLP and OCP is removed and IO is back
within the specifications.
It is not recommended to prolong the duration of IO when it is
<120% but >100%, since it may cause damage to the PSU.
Short Circuit Protection
The power supply’s output OLP/OCP function also provides
protection against short circuits. When a short circuit is applied,
the output current will operate in “Hiccup mode”, as shown in the
illustration in the OLP/OCP section on this page. The power
supply will return to normal operation after the short circuit is
removed.
Overvoltage Protection
The power supply’s overvoltage circuit will be activated when its
internal feedback circuit fails. The output voltage shall not exceed
its specifications defined on Page 3 under “Protections”.
Over Temperature Protection
As mentioned above, the power supply also has Over
Temperature Protection (OTP). In the event of a higher operating
temperature at 100% load, the power supply will run into OTP
when the operating temperature is beyond what is recommended
in the de-rating graph. When activated, the output voltage will go
into bouncing mode until the temperature drops to its normal
operating temperature as recommended in the de-rating graph.
TECHNICAL DATASHEET
PMH Panel Mount Pow er Supply
24V 100W 1
Phase
/ PMH-24V100WCA
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (December 2014, Rev. 01)
11
Operating Mode
Redundancy Operation
In order to ensure proper redundancy operation for the power supply unit (PSU), ensure that the output voltage difference between the
two units is kept at 0.45~0.50V for 24V supplies. Follow simple steps given below to verify:
Step 1.
Measure output voltage of PSU 1 and PSU 2. If PSU 1 is the master unit, then VO of PSU 1 must be higher than PSU 2. In order to set
the output voltage, connect the power supply to 50% load and set the PSU 1 and PSU 2 output voltage.
Step 2.
Connect the right DRR module, 20A as per the system requirement to the power supply units PSU 1 and PSU 2 at Vin 1 & Vin 2
respectively.
Step 3.
Connect the system load from Vout. Please note that output voltage Vout from DRR module will be = VO (output voltage of power
supply) – Vdrop* (in DRR module).
Parallel Operation
These DRR modules can also be used for Parallel function in order to increase the output power by N+1 (e.g. 2.5A + 2.5A = 5A or 2.5A
+ 2.5A + 2.5A = 7.5A) or current sharing, and thus increasing the power supply and system reliability. Though the
PMH-24V100WCA is not designed for current sharing, a good current sharing between two power supplies can be achieved by
following simple steps as below (Refer to Fig. 3 for the Connection Diagram).
*Vdrop will vary from 0.60V to 0.90V (Typical 0.65V) depending on the load current and surrounding air temperature.
Fig. 3 Redundancy / Parallel Operation Connection Diagram
Step 1.
Set output load condition for both supplies at 50% and measure
the output voltages.
Step 2.
Adjust output voltages to the same level or within ±25mV
difference.
Step 3.
Connect PSU 1 and PSU 2 with the DRR-20A module and
measure at Vin 1 & Vin 2 to verify the voltage difference. Ensure
the voltages are within ±25mV.
Step 4.
Output voltage from DRR module Vout will be = VO (output
voltage of power supply) Vdrop* (in DRR module).
TECHNICAL DATASHEET
PMH Panel Mount Pow er Supply
24V 100W 1
Phase
/ PMH-24V100WCA
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (December 2014, Rev. 01)
12
Others
Delta RoHS Compliant
Restriction of the usage of hazardous substances
The European directive 2011/65/EU limits the maximum impurity level of homogeneous materials such as lead,
mercury, cadmium, chrome, polybrominated flame retardants PBB and PBDE for the use in electrical and
electronic equipment. RoHS is the abbreviation for “Restriction of the use of certain hazardous substances in
electrical and electronic equipment”.
This product conforms to this standard.
PFC Norm EN 61000-3-2
Line Current Harmonic content
Typically, the input current waveform is not sinusoidal due to the periodical peak charging of the input capacitor.
In industrial environment, complying with EN 61000-3-2 is only necessary under special conditions. Complying
to this standard can have some technical drawbacks, such as lower efficiency as well as some commercial
aspects such as higher purchasing costs. Frequently, the user does not profit from fulfilling this standard,
therefore, it is important to know whether it is mandatory to meet this standard for a specific application.
Mouser Electronics
Authorized Distributor